Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements for safety
5 Fire
6 Limiting conditions
7 Cable designation
8 Initial and periodic inspections
9 Electrical test after installation
Annex A (informative) - Recommended current ratings
        for railway rolling stock cables
Annex B (informative) - Recommended short-circuit
        current ratings for rolling stock cables of
        90 degrees C maximum conductor temperature
Bibliography

This European Standard gives guidance in the safe use of rolling stock cables specified in EN 50264, EN 50306 and EN 50382.These cables shall only be used for the wiring of railway rolling stock and within the limits given in the manner described in this European Standard. All these cables are for fixed installation where there is no free movement of cable, except for stresses due to typical service. This European Standard is to be applied in conjunction with the relevant product and installation standards. Stricter requirements than those given in this standard could be necessary; see in particular EN 50343. This European Standard is not applicable to: –intercarriage jumpers; –cables subject to continual flexing; –pantograph cables; –coaxial, data and fibre optic cables; –wire wrap; –cables rated at voltages greater than 3,6/6 kV; –applications other than the cabling of railway rolling stock; –cables requiring circuit integrity. Legal or statutory requirements do take precedence over the guidance given in this document. In cases where no guidance exists or where it cannot be derived from general information, it is recommended that advice shall be sought from the cable manufacturer.

Committee
CLC/TC 20
DevelopmentNote
Supersedes PREN 50355. (09/2013) To be read in conjunction with EN 50264 (series), EN 50306 (series), EN 50382 (series) & EN 50343. (09/2013)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
CEI EN 50355 : 2014 Identical
I.S. EN 50355:2013 Identical
SN EN 50355 : 2013 Identical
VDE 0260-355:2015-02 Identical
BS EN 50355:2013 Identical
UNE-EN 50355:2003 Identical
UNE-EN 50355:2013 Identical
PN EN 50355 : 2014 Identical
NEN EN 50355 : 2013 Identical
NBN EN 50355 : 2013 Identical
DIN EN 50355:2015-02 Identical
NF EN 50355 : 2013 Identical
PNE-EN 50355 Identical

BS EN 50264-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Standard wall Multicore cables
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
I.S. EN 50264-3:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 3: MULTICORE CABLES
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 50502:2015 Railway applications - Rolling stock - Electric equipment in trolley buses - Safety requirements and current collection systems
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 50264-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
05/30133180 DC : 0 EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
CEI EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
05/30137080 DC : 0 EN 50264-2-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON - MULTICORE CABLES
05/30137085 DC : 0 EN 50264-3-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
I.S. EN 50264-2:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 2: SINGLE CORE CABLES
CEI EN 50343 : 2015 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
12/30235292 DC : 0 BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
13/30252783 DC : 0 BS EN 50502 - RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRIC EQUIPMENT IN TROLLEY BUSES - SAFETY REQUIREMENTS AND CONNECTION SYSTEMS
BS EN 50306-2:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables
BS EN 50343 : 2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30136253 DC : 0 EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50502:2015 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRIC EQUIPMENT IN TROLLEY BUSES - SAFETY REQUIREMENTS AND CURRENT COLLECTION SYSTEMS
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
CEI EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
CEI EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
BS EN 50306-1:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
05/30136249 DC : 0 EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50306-4:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed
05/30133183 DC : 0 EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
UNE-EN 50502:2016 Railway applications - Rolling stock - Electric equipment in trolley buses - Safety requirements and current collection systems
PREN 50502 : DRAFT 2013 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRIC EQUIPMENT IN TROLLEY BUSES - SAFETY REQUIREMENTS AND CONNECTION SYSTEMS
BS EN 50502:2015 Railway applications. Rolling stock. Electric equipment in trolley buses. Safety requirements and current collection systems
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50306-2:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
I.S. EN 50343:2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50306-1:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 50306-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
05/30137088 DC : 0 EN 50264-3-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON WITH REDUCED DIMENSIONS - MULTICORE CABLES
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
BS EN 50306-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50306-3:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50343 : 2014 AMD 1 2017 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
EN 50264-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 3: Multicore cables

EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
EN 50121-1:2017 Railway applications - Electromagnetic compatibility - Part 1: General
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50215:2009 Railway applications - Rolling stock - Testing of rolling stock on completion of construction and before entry into service
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50125-1:2014 Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment
EN 50362:2003 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 50306-4:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 50306-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.