EN 60076-11:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Power transformers - Part 11: Dry-type transformers
29-01-2022
28-07-2004
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
4.1 General
4.2 Normal service conditions
4.3 Electromagnetic compatibility (EMC)
4.4 Provision for unusual service conditions
4.5 Transport and storage conditions
5 Tappings
6 Connections
7 Ability to withstand short circuit
8 Rating
8.1 General
8.2 Rated power
8.3 Preferred values of rated power
8.4 Operation at higher than rated voltage
8.5 Operation with fan cooling
8.6 Operation in an enclosure
9 Rating plate
9.1 Rating plate fitted to the transformer
9.2 Rating plate fitted to the transformer enclosure
10 Identification according to cooling method
10.1 Identification symbols
10.2 Arrangement of symbols
11 Temperature-rise limits
11.1 Normal temperature-rise limits
11.2 Reduced temperature rises for transformers designed
for high cooling air temperatures or special air cooling
conditions
11.3 High altitude temperature rise correction
12 Insulation levels
12.1 General
12.2 Transformers for use at high altitudes
13 Climatic, environmental and fire behaviour classes
13.1 Climatic classes
13.2 Environmental classes
13.3 Fire behaviour classes
13.4 Test criteria for climatic, environmental and fire
behaviour classes
14 General requirements for tests
15 Measurement of winding resistance (routine test)
16 Measurement of voltage ratio and check of phase displacement
(routine test)
17 Measurement of short-circuit impedance and load loss
(routine test)
18 Measurement of no-load loss and current (routine test)
19 Separate-source AC withstand voltage test (routine test)
20 Induced AC withstand voltage test (routine test)
21 Lightning impulse test (type test)
22 Partial discharge measurement (routine and special test)
22.1 General
22.2 Basic measuring circuit (typical only)
22.3 Calibration of the measuring circuit
22.4 Voltage application
22.5 Partial discharge acceptance levels
23 Temperature-rise test (type test)
23.1 General
23.2 Methods of loading
23.3 Winding temperature-rise correction for reduced current
23.4 Determination of steady state conditions
24 Measurement of sound level (special test)
25 Short-circuit test (special test)
26 Environmental test (special test)
26.1 General
26.2 Validity of the test
26.3 Testing procedure
27 Climatic test (special test)
27.1 Thermal shock test (special test)
27.2 Validity of the test
27.3 Thermal shock test for C1 class transformers
27.4 Thermal shock test for C2 class transformers
28 Fire behaviour test (special test)
28.1 General
28.2 Checking of corrosive and harmful gases emission
28.3 Fire behaviour test for F1 class transformer
28.4 Quantities to be measured and measuring devices
28.5 Calibration of the test chamber without test object
28.6 Test method
28.7 Test report
28.8 Criteria for evaluating the test results
29 Tolerances
30 Protection against direct contact
31 Degrees of protection provided by enclosures
32 Earthing terminal
33 Information required with enquiry and order
Annex A (informative) Installation and safety of dry-type
transformers
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figures
Tables
Applies to dry-type power transformers (including auto-transformers) having values of highest voltage for equipment up to and including 36 kV and at least one winding operating at greater than 1,1 kV. Applies to all construction technologies.
Committee |
CLC/TC 14
|
DevelopmentNote |
Supersedes EN 60726 (07/2004)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
PN EN 60076-11 : 2006 | Identical |
CEI EN 60076-11 : 2006 | Identical |
BS EN 60076-11:2004 | Identical |
UNE-EN 60076-11:2005 | Identical |
NBN EN 60076-11 : 2005 | Identical |
DIN EN 60076-11 : 2005 | Identical |
I.S. EN 60076-11:2004 | Identical |
NF EN 60076-11 : 2004 | Identical |
VDE 0532-76-11 : 2005 | Identical |
NEN EN IEC 60076-11 : 2004 | Identical |
BS EN 50329 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
UNE-EN 50541-1:2012 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
UNE-EN 61378-1:2012 | Convertor transformers -- Part 1: Transformers for industrial applications |
BS EN 60214-1:2014 | Tap-changers Performance requirements and test methods |
BS EN 60076-6:2008 | Power transformers Reactors |
I.S. EN 60076-16:2011 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011) |
I.S. EN 62271-212:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS) |
UNE-EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
EN 61558-2-2:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-2: Particular requirements and tests for control transformers and power supplies incorporating control transformers |
EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
I.S. EN 61558-2-2:2007 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 2-2: PARTICULAR REQUIREMENTS AND TESTS FOR CONTROL TRANSFORMERS AND POWER SUPPLIES INCORPORATING CONTROL TRANSFORMERS |
CEI EN 60076-5 : 2007 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT |
BS EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements |
CEI EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS |
I.S. EN 50600-2-2:2014 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-2: POWER DISTRIBUTION |
I.S. EN 60076-5:2006 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT-CIRCUIT |
I.S. EN 62271-202:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
BS EN 50600-2-2:2014 | Information technology. Data centre facilities and infrastructures Power distribution |
CEI EN 61378-1 : 2012 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
CEI EN 61558-2-1 : 2007 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 2-1: PARTICULAR REQUIREMENTS AND TESTS FOR SEPARATING TRANSFORMERS AND POWER SUPPLIES INCORPORATING SEPARATING TRANSFORMERS FOR GENERAL APPLICATIONS |
I.S. EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
NF EN 50541-1 : 2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
BS EN 60076-16:2011 | Power transformers Transformers for wind turbines applications |
CEI EN 50541-1 : 2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
PREN 50541-1 : DRAFT 2009 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
UNE-EN 62271-202:2015 | High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation |
EN 50600-2-2:2014 | Information technology - Data centre facilities and infrastructures - Part 2-2: Power distribution |
EN 50532:2010 | Compact Equipment Assembly for Distribution Substations (CEADS) |
CEI EN 61558-2-2 : 2007 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 2-2: PARTICULAR REQUIREMENTS AND TESTS FOR CONTROL TRANSFORMERS AND POWER SUPPLIES INCORPORATING CONTROL TRANSFORMERS |
09/30211604 DC : 0 | BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
BS EN 60076-5:2006 | Power transformers Ability to withstand short-circuit |
I.S. EN 50532:2010 | COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
BS EN 61378-1:2011 | Convertor transformers Transformers for industrial applications |
BS EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
UNE-EN 60076-16:2012 | Power transformers - Part 16: Transformers for wind turbines applications |
BS EN 60076-1:2011 | Power transformers General |
08/30184551 DC : DRAFT JUNE 2008 | BS EN 50329 AMD1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
CEI EN 60076-1 : 2015 | POWER TRANSFORMERS - PART 1: GENERAL |
I.S. EN 50541-1:2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
CEI EN 60076-6 : 2015 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
I.S. EN 60076-6:2008 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 61558-2-1:2007 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 2-1: PARTICULAR REQUIREMENTS AND TESTS FOR SEPARATING TRANSFORMERS AND POWER SUPPLIES INCORPORATING SEPARATING TRANSFORMERS FOR GENERAL APPLICATIONS |
BS EN 62271-212:2017 | High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS) |
BS EN 50532:2010 | Compact equipment assembly for distribution substations (CEADS) |
UNE-EN 60076-1:2013 | Power transformers - Part 1: General |
UNE-EN 50329:2004 | Railway applications - Fixed installations - Traction transformers |
09/30202403 DC : 0 | BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
UNE-EN 50532:2011 | Compact Equipment Assembly for Distribution Substations (CEADS) |
BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
UNE-EN 61936-1:2012 | Power installations exceeding 1 kV a.c. -- Part 1: Common rules |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
BS EN 61558-2-2:2007 | Safety of power transformers, power supplies, reactors and similar products Particular requirements and tests for control transformers and power supplies incorporating control transformers |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
I.S. EN 50329:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
I.S. EN 61378-1:2011 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011) |
BS EN 62271-202:2014 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60076-1:2011 | Power transformers - Part 1: General |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 60905:1987 | Loading guide for dry-type power transformers |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.