• There are no items in your cart

EN 60507:2014

Current

Current

The latest, up-to-date edition.

Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems

Published date

21-03-2014

Sorry this product is not available in your region.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General test requirements
5 Salt fog method
6 Solid layer methods
Annex A (informative) - Supplementary information on the
        assessment of the requirement for the testing plant
Annex B (informative) - Determination of the withstand
        characteristics of insulators
Annex C (informative) - Measurement of layer conductivity for
        checking the uniformity of the layer
Annex D (informative) - Additional recommendations concerning
        the solid layer method procedures
Annex E (informative) - Supplementary information on artificial
        pollution tests on insulators for voltage systems of
        800 kV and above (solid layer method procedure B)
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their corresponding
         European publications

IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary. This edition includes the following significant technical changes with respect to the previous edition: a) Corrections and the addition of explanatory material; b) The addition of Clause 4.3.2 on atmospheric correction; c) The change of the upper limit of conductivity of water to 0.1 S/m; and d) The extension to UHV voltages.

Committee
CLC/SR 36
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
NEN 10507 : 1993 Identical
PN EN 60507 : 2014 Identical
UNE-EN 60507:1995 Identical
NF EN 60507 : 2014 Identical
I.S. EN 60507:2014 Identical
CEI EN 60507 : 2014 Identical
SS-EN 60507 : 2014 Identical
SN EN 60507 : 2014 Identical
IEC 60507:2013 Identical
NBN EN 60507 : 2014 Identical
VDE 0448-1 : 2014 Identical
DIN EN 60507 : 2014 Identical
NEN EN IEC 60507 : 2014 Identical
BS EN 60507:2014 Identical
UNE-EN 60507:2014 Identical
PN IEC 507 : 1998 Identical

UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
UNE-EN 50341-1:2017 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
BS EN 61952:2008 Insulators for overhead lines. Composite line post insulators for A.C. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria
BS EN 50152-3-3:2016 Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Voltage transformers
11/30235280 DC : 0 BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
15/30298489 DC : 0 BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
PREN 50152-3-2 : DRAFT 2015 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
I.S. EN IEC 60099-5:2018 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
I.S. EN 50152-3-3:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - VOLTAGE TRANSFORMERS
I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 50152-3-3:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers
EN 62223 : 2009 INSULATORS - GLOSSARY OF TERMS AND DEFINITIONS
EN 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
EN 50152-3-2:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers
OVE/ONORM EN 50124-1 : 2011-05 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
BS EN 50152-1 : 2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN IEC 60099-8:2018 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
CEI EN 62217 : 2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
PREN 50124-1 : DRAFT 2015 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
EN IEC 60099-8:2018 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. EN 62146-1:2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
CEI EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
I.S. EN 60099-4:2014 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
VDE 0674-1 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
DIN EN 60168 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
15/30314795 DC : 0 BS EN 50152-3-3 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS
PREN 50152-3-3 : DRAFT 2015 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
BS EN 60099-8:2011 Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
BS EN 62217:2013 Polymeric HV insulators for indoor and outdoor use. General definitions, test methods and acceptance criteria
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
BS EN 62271-1:2017 High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear
PREN 50152-1 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 62146-1 : 2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013)
I.S. EN 50152-3-2:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
UNE-EN 50152-3-2:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers
BS EN 60060-1:2010 High-voltage test techniques General definitions and test requirements
EN IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
15/30314792 DC : 0 BS EN 50152-3-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
BS EN 50124-1:2017 Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
BS EN 60099-9:2014 Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations
11/30235283 DC : 0 BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
UNE-EN 50152-1:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
BS EN 50152-2:2012 Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV
CEI EN 60060-1 : 2015 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
I.S. EN 50152-1:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 62217:2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA (IEC 62217:2012 (EQV))
I.S. EN 60099-8:2011 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
PREN 50152-2 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 50152-2 : 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
I.S. EN 60060-1:2010 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
I.S. EN 60071-1:2006 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
UNE-EN 50152-3-3:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
UNE-EN 60060-1:2012 High-voltage test techniques - Part 1: General definitions and test requirements
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
UNE-EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
BS EN 62223:2009 Insulators. Glossary of terms and definitions
BS EN 60071-1 : 2006 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
CEI EN 60071-2 : 1998 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
BS EN 60099-4:2014 Surge arresters Metal-oxide surge arresters without gaps for a.c. systems
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
CEI EN 60099-8 : 2012 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
I.S. EN 62271-1:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR
EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62146-1:2014/A1:2016 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016)
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES

IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.