EN IEC 61076-2-111:2018
Current
The latest, up-to-date edition.
Connectors for electrical and electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking
09-03-2018
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Technical information
5 Dimensional information
6 Characteristics
7 Test schedule
Annex A (informative) - Diameter of the female
connector body and orientation of coding
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61076-2-111:2017 specifies 4 to 6-way circular connectors with M12 screw-locking with current ratings up to 16 A and voltage ratings of 63 V or 630 V, that are typically used for power supply and power applications in industrial premises. These connectors consist of both, fixed and free connectors either rewireable or non-rewireable, with M12 screw-locking. Male connectors have round contacts Ø1,0 mm and Ø1,5 mm.The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces, covered by other standards and the cross-mating between the different codings provided by this document.M12 is the dimension of the thread of the screw locking mechanism of these circular connectors.Keywords: Connectors, Circular Connectors, M12.
Committee |
CLC/SR 48B
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
UNE-EN IEC 61076-2-111:2018 | Identical |
IEC 61076-2-111:2017 | Identical |
CEI EN IEC 61076-2-111 : 2018 | Identical |
DIN EN IEC 61076-2-111 : 2018-10 | Identical |
VDE 0687-76-2-111: 2018-10 | Identical |
BS EN IEC 61076-2-111:2018 | Identical |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60352-2:2006/A1:2013 | SOLDERLESS CONNECTIONS - PART 2: CRIMPED CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
EN 60512-19-3:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 19: Chemical resistance tests - Section 3: Test 19c - Fluid resistance |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
IEC 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
EN 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
EN 60068-2-60:2015 | Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60512-9-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
EN 60512-11-1:1999 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60512-13-5:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-5: Mechanical operation tests - Test 13e: Polarizing and keying method |
IEC 60068-2-60:2015 RLV | Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test |
EN 60352-3:1994 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
EN 60512-11-12:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-12: Climatic tests - Test 11m: Damp heat, cyclic |
EN ISO 1302:2002 | Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation (ISO 1302:2002) |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
ISO 11469:2016 | Plastics — Generic identification and marking of plastics products |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
EN 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-5-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise |
EN ISO 11469:2016 | Plastics - Generic identification and marking of plastics products (ISO 11469:2016) |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60512-16-5:2008 | Connectors for electronic equipment - Tests and measurements - Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) |
EN 60512-5-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise |
EN 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 60512-13-2 : 2006 COR 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 13-2: MECHANICAL OPERATION TESTS - TEST 13B: INSERTION AND WITHDRAWAL FORCES |
EN 60352-5:2012/AC:2014 | SOLDERLESS CONNECTIONS - PART 5: PRESS-IN CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE (IEC 60352-5:2012) |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
EN 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11- 7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
EN 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
EN 60512-9-2:2012 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
EN 60512-16-5:2008 | Connectors for electronic equipment - Tests and measurements - Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) |
IEC 60512-11-1:1995 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
EN 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60512-19-3:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 19: Chemical resistance tests - Section 3: Test 19c - Fluid resistance |
IEC 60512-11-12:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-12: Climatic tests - Test 11m: Damp heat, cyclic |
EN 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 62197-1 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - QUALITY ASSESSMENT REQUIREMENTS - PART 1: GENERIC SPECIFICATION |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
EN 60512-13-5:2006/corrigendum Dec. 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 13-5: MECHANICAL OPERATION TESTS - TEST 13E: POLARIZING AND KEYING METHOD |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
EN 60352-4:1994/A1:2000 | SOLDERLESS CONNECTIONS - PART 4: SOLDERLESS NON-ACCESSIBLE INSULATION DISPLACEMENT CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 62197-1:2006 | Connectors for electronic equipment - Quality assessment requirements - Part 1: Generic specification |
EN 61984:2009 | Connectors - Safety requirements and tests |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
EN 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
EN 60512-6-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
EN 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
EN 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
EN 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.