• There are no items in your cart

IEC 60099-8:2017

Current

Current

The latest, up-to-date edition.

Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, English - French

Published date

14-11-2017

€358.68
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and classification
5 Standard ratings and service conditions
6 Requirements
7 General testing procedure
8 Type tests
9 Routine tests
10 Acceptance tests
Annex A (informative) - Example of a test
        circuit for the follow current
        interrupting test
Annex B (normative) - Mechanical considerations
Annex C (normative) - Special service conditions
Bibliography

IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers. This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document:
- switching impulse spark-over voltage;
- residual voltage at steep current and switching current impulse;
- thermal stability;
- long-duration current impulse withstand duty;
- power-frequency voltage versus time characteristics of an arrester;
- disconnector test;
- aging duties by power-frequency voltage.
Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced.
- Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA.
- Definitions for new terms have been added
- A number of NOTES in Ed. 1 have been converted to normative requirements
Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

Committee
TC 37
DevelopmentNote
Stability Date: 2020. (11/2017)
DocumentType
Standard
Pages
67
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

17/30339060 DC : 0 BS EN 60071-2 - INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE (PROPOSED HORIZONTAL STANDARD)
IEC 60099-5:2018 RLV Surge arresters - Part 5: Selection and application recommendations
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
IEC 60071-2:2018 RLV Insulation co-ordination - Part 2: Application guidelines
16/30340451 DC : DRAFT APR 2016 BS EN 60099-5 - SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
EN IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
I.S. EN IEC 60071-2:2018 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDELINES
NF EN 60099-5 : 2017 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
EN IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
10/30210015 DC : 0 BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN IEC 60099-5:2018 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
ISO 4892-1:2016 Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
ISO 4287:1997 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions and surface texture parameters
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
ISO 4892-3:2016 Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
ISO 3274:1996 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Nominal characteristics of contact (stylus) instruments
ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.