IEC 60502:1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-12-1997
English - French
30-08-1994
Foreword
Section 1 - General
Clause
1 Scope
2 Definitions
Section 2 - Construction
3 Conductors
4 Insulation
5 Screening of ores
6 Assembly of cores, inner coverings and fillers
7 Metallic layers for single-core and multicore cables
8 Metallic screen
9 Concentric conductor
10 Metallic sheath
11 Metallic armour
Tables 1 to 4
Section 3 - Test requirements
13 Test conditions
14 Routine tests
15 Special tests
16 Type tests, electrical
17 Type tests, non-electrical
18 Electrical test after installation
Tables 5 to 12
Annexes
A The fictitious calculation method for determination of
dimensions of protective coverings
B Rounding of numbers
Specifies the construction, dimensions and test requirements of power cables with extruded solid insulation of the types listed in 1.2, for rated voltages (u) from 1 kV up to and including 30 kV given in 1.3, for fixed installations. Cables for special conditions of installations and service are not included.
DocumentType |
Standard
|
Pages |
109
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
VDE 0472-505 : 1983 | Identical |
NEN 3620 : 2003 C1 2003 | Identical |
VDE 0272 : 1989 | Identical |
VDE 0273 : 1987 | Identical |
DIN VDE 0472-505 : 1983 | Identical |
NBN IEC 502 : 1994 | Identical |
BS 6622:1985 | Similar to |
ESI 43-13 : ISSUE 2 | AERIAL BUNDLED CONDUCTORS (ABC) INSULATED WITH CROSS LINKED POLYETHYLENE FOR LOW VOLTAGE OVERHEAD DISTRIBUTION |
NF EN 60684-3-282 : 2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 282: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, STRESS CONTROL |
BS EN 45510-2-8:2004 | Guide for procurement of power station equipment Electrical equipment - Power cables |
CEI UNI EN 45510-2-8 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
PREN ISO 12696 : DRAFT 2009 | CATHODIC PROTECTION OF STEEL IN CONCRETE |
I.S. HD 622:1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6(7,2) KV UP TO AND INCLUDING 20,8/36(42) KV WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
EN 45510-2-8 : 2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
ENA TS 09-17 : ISSUE 2 AMD 1 1995 | SINGLE CORE CABLES FOR USE IN SUBSTATIONS HAVING EXTRUDED INSULATION AND RATED VOLTAGES OF 6350/11000 VOLTS AND 19000/33000 VOLTS |
ENA TS 09-13 : ISSUE 1 AMD 1 1993 | PERFORMANCE SPECIFICATION FOR HIGH VOLTAGE HEAT SHRINKABLE COMPONENTS FOR USE WITH HIGH VOLTAGE SOLID TYPES CABLES UP TO AND INCLUDING 33000 VOLTS |
API RP 17I : 1996 | INSTALLATION GUIDELINES FOR SUBSEA UMBILICALS |
I.S. EN 12696:2000 | CATHODIC PROTECTION OF STEEL IN CONCRETE |
NF EN 60684-3-281 : 2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 281: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, SEMICONDUCTIVE |
98/232755 DC : DRAFT DEC 1998 | IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
IEEE C37.63-2013 REDLINE | IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
I.S. HD 627:2003 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
ISO 19859:2016 | Gas turbine applications Requirements for power generation |
I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
VDE 0299-2 : 1994 | CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
VDE 0278-623 : 97 AMD 1 2004 | POWER CABLE ACCESSORIES WITH RATED VOLTAGES U UP TO 30 KV (U[M] UP TO 36 KV) - PART 623: SPECIFICATION FOR JOINTS, STOP ENDS AND OUTDOOR TERMINATIONS FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
BS 5467:1977 | Specification for armoured cables with thermosetting insulation for electricity supply |
BS 6622:1991 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V |
BS 6883:1991 | Specification for elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units |
BS 5467:1989 | Specification for cables with thermosetting insulation for electricity supply for rated voltages of up to and including 600/1000 V and up to and including 1900/3300 V |
DIN EN 60719 : 1994 | CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
09/30185957 DC : 0 | BS EN ISO 12696 - CATHODIC PROTECTION OF STEEL IN CONCRETE |
BS 6349-3:1988 | Maritime structures Design of dry docks, locks, slipways and shipbuilding berths, shiplifts and dock and lock gates |
08/30184557 DC : DRAFT JUNE 2008 | BS EN 62271-111 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 111: PAD-MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR ALTERNATING CURRENT SYSTEMS UP TO 38 KV |
BS EN 60719:1993 | Calculation for the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
05/30128234 DC : DRAFT FEB 2005 | EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS |
NF EN 60684-3-280 : 2010 AMD 1 2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 280: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, ANTI-TRACKING |
CEI 20-60 : 1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO INCLUDING 20,8/36 (42) KV |
I.S. HD 603:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
ISO 14224:2016 | Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment |
BS 6899:1984 | Specification for rubber insulation and sheath of electric cables |
BS 6899:1991 | Specification for rubber insulation and sheath of electric cables |
BS 7870-2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
EN 45510-2-8:2004 | Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables |
ENA TS 09-20 : ISSUE 1 AMD 1 1993 | SINGLE CORE CABLES HAVING CROSS LINKED POLYETHYLENE INSULATION AND LEAD SHEATH FOR RATED VOLTAGE 19000/33000 VOLTS (UM = 36000 VOLTS) |
NFC 33 051 : 96 AMD 1 1998 XP | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SCREENED SEPARABLE CONNECTORS AND ASSOCIATED DEVICES FOR RATED VOLTAGES FROM 6/10 (12) KV UP TO 18/30 (36) KV |
ESI 09-20 : ISSUE 1 AMD 1 | SINGLE CORE CABLES HAVING CROSS LINKED POLYETHYLENE INSULATION AND LEAD SHEATH FOR RATED VOLTAGE 19000/33000 VOLTS (UM = 36000 VOLTS) |
ESI 09-16 : ISSUE 1 | TESTING SPECIFICATION FOR METALLIC SHEATHED POWER CABLES WITH EXTRUDED CROSS LINKED POLYETHYLENE INSULATION AND ACCESSORIES FOR SYSTEM VOLTAGES OF 66kV AND 132kV |
BS 7769-1.1:1997 | Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses General |
ESI 09-13 : ISSUE 1 | PERFORMANCE SPECIFICATION FOR HIGH VOLTAGE HEAT SHRINKABLE COMPONENTS FOR USE WITH HIGH VOLTAGE SOLID TYPE CABLES UP TO AND INCLUDING 33000 VOLTS |
IEEE 1246-2011 REDLINE | IEEE Guide for Temporary Protective Grounding Systems Used in Substations |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
I.S. EN 60439-1:2000 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
BS EN 12696:2000 | Cathodic protection of steel in concrete |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
BS ISO 19859:2016 | Gas turbine applications. Requirements for power generation |
BS EN 60439-1:1999 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
I.S. EN 45510-2-8:2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
95/215891 DC : DRAFT DEC 1995 | PREN 50213 - PRIMARY CABLES FOR AIRPORT LIGHTING |
ESI 09-17 : ISSUE 2 | SINGLE CORE CABLES FOR USE IN SUBSTATIONS HAVING EXTRUDED INSULATION AND RATED VOLTAGES OF 6350/11000 VOLTS AND 19000/33000 VOLTS |
09/19987837 DC : 0 | BS IEC 60364-7-713 ED2 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-713: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - FURNITURE |
HD 623 : S1 AMD 11 2001 | SPECIFICATION FOR JOINTS, STOP ENDS AND OUTDOOR TERMINATIONS FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 KV |
05/30138201 DC : DRAFT AUG 2005 | ISO 12696 - CATHODIC PROTECTION OF STEEL IN CONCRETE |
CEI EN 60719 : 1997 | CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
I.S. 201-13:2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 13: OIL RESISTANT PVC SHEATHED CABLES WITH TWO OR MORE CONDUCTORS |
IEEE 1511.1 : 2010 | GUIDE FOR INVESTIGATING AND ANALYZING SHIELDED POWER CABLE FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV |
BS 5468:1977 | Specification for cross-linked polyethylene insulation of electric cables |
UNI CEI EN 45510-2-8 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
I.S. HD 623:1999 | SPECIFICATION FOR JOINTS, STOP ENDS AND OUTDOOR TERMINATIONS FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 KV |
14/30244780 DC : 0 | BS ISO 19859 - GAS TURBINE APPLICATIONS - REQUIREMENTS FOR POWER GENERATION |
BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
EN 12696:2000 | Cathodic protection of steel in concrete |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
IEC 60038:2009 | IEC standard voltages |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
IEC 60885-2:1987 | Electrical test methods for electric cables. Part 2: Partial discharge tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.