IEC 60502-2:2014 RLV
Current
The latest, up-to-date edition.
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
20-02-2014
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designations and materials
5 Conductors
6 Insulation
7 Screening
8 Assembly of three-core cables, inner coverings
and fillers
9 Metal layers for single-core and three-core cables
10 Metal screen
11 Concentric conductor
12 Metal sheath
13 Metal armour
14 Oversheath
15 Test conditions
16 Routine tests
17 Sample tests
18 Type tests, electrical
19 Type tests, non-electrical
20 Electrical tests after installation
Annex A (normative) - Fictitious calculation method for
determination of dimensions of protective coverings
Annex B (informative) - Tabulated continuous current ratings
for cables having extruded insulation and a rated
voltage from 3,6/6 kV up to 18/30 kV
Annex C (normative) - Rounding of numbers
Annex D (normative) - Method of measuring resistivity of
semi-conducting screens
Annex E (normative) - Determination of hardness of HEPR
insulations
Annex F (normative) - Water penetration test
Annex G (informative) - Determination of the cable conductor
temperature
Bibliography
IEC 60502-2:2014 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60502-2:2014 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. When determining applications, it is recommended that the possible risk of radial water ingress is considered. Cable designs with barriers claimed to prevent longitudinal water penetration and an associated test are included in this part of IEC 60502. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area) nor for submarine use or shipboard application. This third edition cancels and replaces the second edition, published in 2005, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) a simplified calculation procedure for the thickness of the lead sheath and the oversheath;
b) a new subclause for the determination of the cable conductor temperature;
c) a modified procedure for the routine voltage test;
d) a new subclause for a routine electrical test on oversheath;
e) modified requirements for the non-metal sheaths including semi-conductive layer;
f) modified tolerances for the bending test cylinder;
g) the inclusion of a 0,1Hz test after installation.
In addition, the modified structure of the IEC 60811 series has been adopted for this third edition.
Committee |
TC 20
|
DevelopmentNote |
Stability date: 2017. (03/2014)
|
DocumentType |
Redline
|
Pages |
270
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DS IEC 60502-2 : 2014 | Identical |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
BS IEC 62895:2017 | High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements |
16/30337938 DC : 0 | BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
07/30143023 DC : DRAFT MAR 2007 | BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
11/30214073 DC : 0 | BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES |
BS 7870-4.10(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620) |
08/30189625 DC : 0 | BS EN 10257-1 - ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
05/30136422 DC : DRAFT JULY 2005 | |
BS EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
CEI 18-52 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 354: SINGLE- AND THREE-CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (U[M] = 7,2 KV) UP TO 30 KV (U[M] = 36 KV) |
IEEE 1242-1999 | IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants |
I.S. EN 61442:2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
NFC 33 062 : 1999 | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV) |
IEC/ISO/IEEE 80005-1:2012 | Utility connections in port - Part 1: High Voltage Shore Connection (HVSC) Systems - General requirements |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
BS 7870-4.11(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620) |
EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
CEI 18-64 : 2008 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES |
EN 10257-1:2011 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
BS 7870-4.20(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620) |
CEI 18-49 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS |
07/30127452 DC : DRAFT AUG 2007 | BS ISO 13628-5 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
06/30143016 DC : DRAFT SEP 2006 | BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV |
PREN 10257-1 : DRAFT 2008 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
BS IEC 60287-1-1 : 2006 | ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL |
UNE-IEC 60092-350:2015 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
I.S. EN 10257-1:2011 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
BS 6622:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods |
BS 7835:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods |
ESPECIFICACION UNE 0051:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3). |
EA 0051:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
API SPEC 17E : 2017 | SPECIFICATION FOR SUBSEA UMBILICALS |
11/30214077 DC : 0 | BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES |
ESPECIFICACION UNE 0052:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
API 17E REDLINE : 2010 | SPECIFICATION FOR SUBSEA UMBILICALS |
CEI 20-60 : 1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO INCLUDING 20,8/36 (42) KV |
CEI 20-21/1-1 : 2007 | ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL |
IEC TS 62100:2004 | Cables for aeronautical ground lighting primary circuits |
EEMUA 133 : 2011 | SPECIFICATION FOR UNDERGROUND ARMOURED CABLE PROTECTED AGAINST SOLVENT PENETRATION AND CORROSIVE ATTACK |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
UNI EN 10257-1 : 2011 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
CEI EN 61442 : 2006 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
14/30290103 DC : 0 | BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS |
11/30214075 DC : 0 | BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES |
BS ISO/IEC/IEEE 80005-1:2012 | Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
UNI EN ISO 13628-5 : 2010 | PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
14/30316181 DC : 0 | BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
IEEE 400-2012 REDLINE | IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above |
01/202703 DC : DRAFT APRIL 2001 | IEC 60092-354 ED.2 - ELECTRICAL INSULATION IN SHIPS - PART 354: SINGLE AND THREE CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (UM EQUALS 7.2 KV) UP TO 30 KV (UM EQUALS 36 KV) |
BS ISO 13628-5:2002 | Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals |
PREN 50628 : DRAFT 2014 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) |
BS EN 10257-1:2011 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables Land cables |
ISO 13628-5:2009 | Petroleum and natural gas industries Design and operation of subsea production systems Part 5: Subsea umbilicals |
UNE-EN 10257-1:2012 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
UNE-IEC 61892-4:2016 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
EN ISO 13628-5:2009 | Petroleum and natural gas industries - Design and operation of subsea production systems - Part 5: Subsea umbilicals (ISO 13628-5:2009) |
UNE 21161:2017 | Cables for AGL constant current series circuits. |
IEEE 400.4-2015 | IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage |
I.S. EN ISO 13628-5:2009 | PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
CEI ENV 50213 : 2000 | METALLIC SCREENED CABLES FOR AIRFIELD LIGHTING |
11/30214057 DC : 0 | BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST |
IEEE 1511.1 : 2010 | GUIDE FOR INVESTIGATING AND ANALYZING SHIELDED POWER CABLE FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV |
BS EN ISO 13628-5:2009 | Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals |
NFC 33 061 : 1999 | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - JOINTS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV) |
UNE 21144-1-1:2012 | Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
UNE-IEC 60092-352:2015 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
NF EN 61442 : 2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 36 KV (UM = 42 KV) |
NFC 33 063 : 1999 | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - OUTDOOR TERMINATIONS, WITH PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV) |
DIN EN 10257-1:2012-02 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
EN 50628:2016 | Erection of electrical installations in underground mines |
IEC 60811-501:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds |
IEC 60811-509:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test) |
IEC 60038:2009 | IEC standard voltages |
IEC 60811-507:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials |
IEC 60811-506:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60811-402:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests |
IEC 60811-505:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths |
IEC 60811-503:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths |
IEC 60811-504:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
IEC 60811-203:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions |
IEC 60811-401:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven |
IEC 60811-409:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths |
IEC 60811-202:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60811-606:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
IEC 60811-508:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
IEC 60853-2:1989 | Calculation of the cyclic and emergency current rating of cables. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages |
IEC 60287-3-1:2017 | Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site reference conditions |
IEC 60811-405:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths |
IEC 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
ISO 48:2010 | Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
IEC 60811-201:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness |
IEC 60811-605:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and/or mineral filler in polyethylene compounds |
IEC 60811-502:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations |
IEC 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.