IEC 60811-3-1:1985
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
13-03-2012
01-01-1985
1 Scope
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Pressure test at high temperature for insulations and
sheaths
8.1 Test for insulations
8.2 Test for sheaths
8.3 Test method using a dial micrometer
9 Tests for resistance of insulations and sheaths to
cracking
9.1 Heat shock test for insulations
9.2 Heat shock test for sheaths
FIGURES
APPENDIX A - Corresponding clauses or sub-clauses in
IEC Publications 538 and 540 and IEC
Publication 811
Annex ZA (normative) Normative references to
international publications with their
corresponding European publications
Specifies the test methods to be used for testing polymericinsulating and sheathing materials of electric cables for powerdistribution and telecommunications including cables used on ships.Gives the methods for pressure test at high temperature and fortests for resistance to cracking, which apply to PVC compounds. The contents of the corrigendum of May 1986 have been included inthis copy.
DevelopmentNote |
Also numbered as BS EN 60811-3.1 (06/2002) Supersedes IEC 60538 AND IEC 60540 (07/2004)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 60811-3-1:1996 | Identical |
NF EN 60811 3-1 : 96 AMD 2 2001 | Identical |
NEN EN IEC 60811-3-1 : 1996 AMD 2 2001 | Identical |
NEN 10811-3-1 : 1996 AMD 1 1996 | Identical |
I.S. EN 60811-3-1:1997 | Identical |
PN EN 60811-3-1 : 1999 AMD 2 2002 | Identical |
SAC GB/T 2951-6 : 1997 | Identical |
VDE 0473-811-3-1 : 2002 | Identical |
EN 60811-3-1 : 95 AMD 2 2001 | Identical |
DIN EN 60811-3-1 : 2002 | Identical |
NFC 32 029 : 1988 | Identical |
GOST IEC 60811-3-1 : 2011 | Identical |
HD 505.3.1 : 200S1 | Identical |
GOST R IEC 60811-3-1 : 1994 AMD 1 2002 | Identical |
BS 6469:1990 | Similar to |
BS 6469:1984 | Similar to |
NF EN 50290-2-21 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS |
IEC 60227-3:1993+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring |
CEI EN 50305 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS |
I.S. EN 62012-1:2002 | MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENTS - PART 1: GENERIC SPECIFICATION |
EN 50290-2-27 : 2002 COR 2010 | COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS |
I.S. EN 50363-4-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-1: PVC SHEATHING COMPOUNDS |
BS EN 50363-2-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric covering compounds |
NF EN 61138 : 2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
BS EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC) |
I.S. EN 50363-10-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-2: MISCELLANEOUS SHEATHING COMPOUNDS - THERMOPLASTIC POLYURETHANE |
I.S. EN 61138:2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
BS EN 50290-2-21 : 2002 | COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS |
I.S. EN 50290-2-26:2002 | COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS |
I.S. EN 50363-7:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 7: HALOGEN-FREE, THERMOPLASTIC INSULATING COMPOUNDS |
I.S. EN 50363-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 1: CROSS-LINKED ELASTOMERIC INSULATING COMPOUNDS |
I.S. EN 50363-2-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
EN 50290-2-26 : 2002 AMD 1 2007 | COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
EN 50363-2-1 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
EN 50363-8 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS |
EN 61138:2007 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
EN 50290-2-22 : 2001 AMD 1 2007 | COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS |
EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC) |
EN 60505:2011/AC:2017-03 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017) |
EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC) |
EN 50363-6 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS |
EN 61230:2008 | LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
EN 50363-7:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds |
04/30114758 DC : 0 | IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS |
CEI 18-49 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS |
04/30126718 DC : DRAFT DEC 2004 | IEC 60189-1 ED.3 - LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH - PART 1: GENERAL TEST AND MEASURING METHODS |
BS EN 50290-2-22:2002 | Communication cables Common design rules and construction. PVC sheathing compounds |
08/30159870 DC : DRAFT APR 2008 | BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION |
BS EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables General introduction |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
IEC 60227-4:1992+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring |
I.S. EN 60505:2011 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS |
BS EN 60811-508:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Pressure test at high temperature for insulation and sheaths |
EN 60811-509:2012/A1:2017 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 509: MECHANICAL TESTS - TEST FOR RESISTANCE OF INSULATIONS AND SHEATHS TO CRACKING (HEAT SHOCK TEST) (IEC 60811-509:2012/A1:2017) |
EN 60811-508:2012/A1:2017 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 508: MECHANICAL TESTS - PRESSURE TEST AT HIGH TEMPERATURE FOR INSULATION AND SHEATHS (IEC 60811-508:2012/A1:2017) |
I.S. EN 50363-10-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-1: MISCELLANEOUS SHEATHING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
BS EN 60811-509:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Test for resistance of insulations and sheaths to cracking (heat shock test) |
BS EN 50290-2-27:2002+A1:2007 | Communication cables Common design rules and construction. Halogen free flame retardant thermoplastic sheathing compounds |
I.S. EN 50363-8:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS |
NF EN 61230 : 2009 | LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
IEC 60800:2009 | Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation |
CEI EN 50290-2-30 : 2002 | COMMUNICATION CABLES - PART 2-30: COMMON DESIGN RULES AND CONSTRUCTION POLY(TETRAFLUOROETHYLENE-HEXAFLUOROPROPYLENE) (FEP) INSULATION AND SHEATHING |
IEC 60840:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements |
I.S. EN 50363-5:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS EN 50363-10-2:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Thermoplastic polyurethane |
BS EN 50290-2-26:2002 | Communication cables Common design rules and construction. Halogen free flame retardant insulation compounds |
BS EN 50305:2002 | Railway applications. Railway rolling stock cables having special fire performance. Test methods |
05/30131385 DC : DRAFT MAR 2005 | IEC 61156-1 ED 3 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 1: GENERIC SPECIFICATION |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 50363-3:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
I.S. EN 50363-4-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-2: PVC COVERING COMPOUNDS |
NF EN 50290-2-27 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS |
IEC 60227-6:2001 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections |
IEC 61138:2007 | Cables for portable earthing and short-circuiting equipment |
I.S. EN 50363-6:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS |
IEC 60092-351:2004 | Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables |
05/30128938 DC : DRAFT FEB 2005 | IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
CSA E598.1 : 2002 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
00/201245 DC : DRAFT FEB 2000 | IEC 62029-1 - COAXIAL CABLES USED IN CABLED DISTRIBUTION NETWORKS - PART 1: GENERIC SPECIFICATION AND TEST METHODS |
BS EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables PVC sheathing compounds |
NF EN 50290-2-22 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS |
BS EN 60505:2011 | Evaluation and qualification of electrical insulation systems |
BS EN 50363-4-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables PVC covering compounds |
CEI EN 62012-1 : 2003 | MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENT - PART 1: GENERIC SPECIFICATION |
07/30170224 DC : DRAFT AUG 2007 | BS EN 61230 - LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
NF EN 50305 : 2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS |
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors |
BS EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC) |
BS EN 50363-7:2005 | Insulating, sheathing and covering materials for low voltage energy cables Halogen-free, thermoplastic insulating compounds |
NF EN 50290-2-26 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS |
I.S. EN 50363-9-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
CEI EN 60505 : 2012 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS |
IEC 60227-1:2007 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
UNE-EN 60598-1:2015 | Luminaires - Part 1: General requirements and tests |
I.S. EN 61230:2008 | LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
I.S. EN 50363-0:2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
I.S. EN 50363-2-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-2: CROSS-LINKED ELASTOMERIC COVERING COMPOUNDS |
IEC 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification |
IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
EN 50305:2002 | Railway applications - Railway rolling stock cables having special fire performance - Test methods |
UNE-EN 60811-509:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test) |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60811-508:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths |
UNE-EN 60811-508:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths |
EN 50290-2-21:2001/A1:2007/AC:2016 | COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATING COMPOUNDS |
EN 50363-3 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds |
I.S. EN 60811-509:2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 509: MECHANICAL TESTS - TEST FOR RESISTANCE OF INSULATIONS AND SHEATHS TO CRACKING (HEAT SHOCK TEST) |
BS EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds |
03/308375 DC : DRAFT JUNE 2003 | IEC 61196-1 - COAXIAL COMMUNICATION CABLES - PART 1: GENERIC SPECIFICATION - GENERAL, DEFINITIONS AND REQUIREMENTS |
BS EN 50290-2-30:2002 | Communication cables. Common design rules and construction Poly(tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheathing |
BS EN 61230:2008 | Live working. Portable equipment for earthing or earthing and short-circuiting |
03/318201 DC : DRAFT NOV 2003 | IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV) |
BS EN 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments Generic specification |
BS EN 61138:1998 | Cables for portable earthing and short-circuiting equipment |
UNE-EN 61230:2011 | Live working - Portable equipment for earthing or earthing and short-circuiting |
I.S. EN 60811-508:2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 508: MECHANICAL TESTS - PRESSURE TEST AT HIGH TEMPERATURE FOR INSULATION AND SHEATHS |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
I.S. EN 50290-2-27:2002 | COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS |
UNE-EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
I.S. EN 50290-2-30:2002 | COMMUNICATION CABLES - PART 2-30: COMMON DESIGN RULES AND CONSTRUCTION - POLY(TETRAFLUOROETHYLENE-HEXAFLUOROPROPYLENE) (FEP) INSULATION AND SHEATHING |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 60245-1:2003+AMD1:2007 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements |
I.S. EN 50290-2-21:2001 | COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS |
EN 50363-4-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds |
EN 50363-2-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds |
EN 50363-10-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane |
EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction |
EN 50290-2-30:2002 | Communication cables - Part 2-30: Common design rules and construction - Poly(tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheathing |
EN 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification |
EN 50363-5 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
AS/NZS IEC 60227.5:2019 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Flexible cables (cords) |
HD 505.1.1 : 200S3 | COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES |
IEC 60538A:1980 | First supplement |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.