• IEC 61000-2-12:2003

    Current The latest, up-to-date edition.

    Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  24-04-2003

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Abstract - (Show below) - (Hide below)

    This part of IEC 61000 is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected in public medium voltage power supply systems, for guidance in: a) the limits to be set for disturbance emission into public power supply systems (including the planning levels defined in 3.1.5); b) the immunity limits to be set by product committees and others for the equipment exposed to the conducted disturbances present in public power supply systems. The disturbance phenomena considered are: voltage fluctuations and flicker, harmonics up to and including order 50, inter-harmonics up to the 50th harmonic, voltage distortions at higher frequencies (above 50th harmonic), voltage dips and short supply interruptions, voltage unbalance, transient overvoltages, power frequency variation, d.c. components, mains signalling. The medium-voltage systems covered by this standard are public distribution systems supplying either: a) private installations in which equipment is connected directly or through transformers, or b) substations feeding public low-voltage distribution systems.

    General Product Information - (Show below) - (Hide below)

    Committee TC 77/SC 77A
    Development Note Stability Date: 2017. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
    CLC/TS 50217:2005 Guide for in situ measurements - In situ measurement of disturbance emission
    IEC TR 61000-3-6:2008 Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
    00/244020 DC : DRAFT SEP 2000 IEC 61800-3 ED.2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS PRODUCT STANDARD INCLUDING SPECIFIC TEST METHODS
    PD IEC/TR 61000-3-6:2008 Electromagnetic compatibility (EMC) Limits. Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
    I.S. EN 61800-3:2005 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004 (EQV))
    PD IEC/TR 61000-3-13:2008 Electromagnetic compatibility (EMC) Limits. Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
    12/30262567 DC : 0 BS EN 61000-4-30 ED 3 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    UNE-EN 61000-4-30:2015 Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
    CEI EN 50328 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
    09/30214220 DC : 0 BS IEC TR 61000-2-5 ED - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-5: ENVIRONMENT - CLASSIFICATION OF ELECTROMAGNETIC ENVIRONMENTS
    BS EN 61000-4-30:2015 Electromagnetic compatibility (EMC) Testing and measurement techniques. Power quality measurement methods
    06/30150224 DC : DRAFT MAY 2006 IEC 61000-3-13 TR ED - 1 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    CSA C61000.3.7 :2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    CSA C61000-3-13 : 2009 : R2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    06/30159310 DC : 0 IEC 61000-4-30 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    CSA CEI/IEC 61000.2.4 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    PD CLC/TR 50646:2015 Railway Application. Fixed Installations. Specification for reversible d.c. substations
    S.R. CLC/TR 50646:2015 RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS
    I.S. EN 61000-4-30:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    I.S. EN 50328:2007 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
    EN 61000-2-4:2002/AC:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    CEI EN 61000-2-4 : 2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    14/30279327 DC : 0 BS EN 61800-3 AMD2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS
    13/30256030 DC : 0 BS IEC 62695 ED 1.0 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    DD CLC/TS 50217:2005 Guide for in situ measurements. In situ measurement of disturbance emission
    BS EN 61000-4-19:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    IEEE 1453.1-2012 IEEE Guide--Adoption of IEC/TR 61000-3-7:2008, Electromagnetic compatibility (EMC)--Limits--Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
    07/30164322 DC : 0 BS EN 61000-3-6 ED.2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: ASSESSMENT OF HARMONIC EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    IEC 62695:2014 Railway applications - Fixed installations - Traction transformers
    NF EN 50329 : 2005 AMD 1 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    IEC TR 61000-3-7:2008 Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
    IEC 62590:2010 Railway applications - Fixed installations - Electronic power converters for substations
    IEC TR 61000-2-5 REDLINE : 3ED 2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-5: ENVIRONMENT - DESCRIPTION AND CLASSIFICATION OF ELECTROMAGNETIC ENVIRONMENTS
    06/30150181 DC : DRAFT MAY 2006 IEC 61000-3-7 TR ED.2 - ELECTROMAGNETIC COMPATABILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING LOAD INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    BS EN 61000-2-4:2002 Electromagnetic compatibility (EMC). Environment Compatibility levels in industrial plants for low-frequency conducted disturbances
    BS EN 50328:2003 Railway applications. Fixed installations. Electronic power convertors for substations
    ENA ER G5-4-1 : ISSUE 4 AMD 1 2005 PLANNING LEVELS FOR HARMONIC VOLTAGE DISTORTION AND THE CONNECTION OF NON-LINEAR EQUIPMENT TO TRANSMISSION SYSTEMS AND DISTRIBUTION NETWORKS IN THE UNITED KINGDOM
    CSA C61000-4-30 : 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    CSA C61000.3.6 : 2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    CSA C61000.3.6 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    BS EN 61800-3 : 2004 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS
    I.S. CLC/TS 50217:2005 GUIDE FOR IN SITU MEASUREMENTS - IN SITU MEASUREMENT OF DISTURBANCE EMISSION
    PD IEC/TR 61000-2-5:2017 Electromagnetic compatibility (EMC) Environment. Description and classification of electromagnetic environments
    IEC 62589:2010 Railway applications - Fixed installations - Harmonisation of the rated values for converter groups and tests on converter groups
    IEC TR 61000-2-5:2017 Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
    IEC 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    BS EN 60044-7:2000 Instrument transformers Electronic voltage transformers
    CSA C61000-3-13 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    CSA C61000-3-13 :2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    UNE-EN 61000-4-19:2015 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    IEC TR 61000-3-13:2008 Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
    CSA CEI/IEC 61000.4.30 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    IEC 61800-3:2017 Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods
    IEC TS 62749:2015 Assessment of power quality - Characteristics of electricity supplied by public networks
    IEC 61000-4-30 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
    IEC 61000-4-30:2015 RLV Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
    CSA C61000.3.7 : 2009 : R2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    CSA C61000.3.7 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
    PD IEC/TR 61000-3-7:2008 Electromagnetic compatability (EMC) Limits. Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
    CSA C61000-4-30 : 2010 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    NF EN 50327 : 2005 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
    I.S. EN 61000-4-19:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-19: TESTING AND MEASUREMENT TECHNIQUES - TEST FOR IMMUNITY TO CONDUCTED, DIFFERENTIAL MODE DISTURBANCES AND SIGNALLING IN THE FREQUENCY RANGE 2 KHZ TO 150 KHZ AT A.C. POWER PORTS
    I.S. EN 61000-2-4:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    NF EN 50328 : 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
    EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
    EN 61800-3 : 2004 AMD 1 2012 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011)
    IEC TR 61000-2-5:2017 RLV Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
    EN 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    CLC/TR 50646:2015 Railway Application - Fixed Installations - Specification for reversible d.c. substations

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60038:2009 IEC standard voltages
    IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
    IEC 61037:1990+AMD1:1996+AMD2:1998 CSV Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers
    SA TR IEC 61000.2.5:2019 Electromagnetic compatibility (EMC) Environment - Description and classification of electromagnetic environments
    IEC 60050-101:1998 International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics
    IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
    IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
    IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC 60050-551-20:2001 International Electrotechnical Vocabulary (IEV) - Part 551-20: Power electronics - Harmonic analysis
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective