Application of Markov techniques
Hardcopy , PDF
English - French
18-05-2006
This International Standard provides guidance on the application of Markov techniques to model and analyze a system and estimate reliability, availability, maintainability and safety measures. This standard is applicable to all industries where systems, which exhibit state-dependent behaviour, have to be analyzed. The Markov techniques covered by this standard assume constant time-independent state transition rates. Such techniques are often called homogeneous Markov techniques.
| Committee |
TC 56
|
| DevelopmentNote |
Stability Date: 2018. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
67
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NF EN 61165 : 2006 | Identical |
| NEN EN IEC 61165 : 2006 | Identical |
| I.S. EN 61165:2006 | Identical |
| PN EN 61165 : 2006 | Identical |
| AS IEC 61165-2008 | Identical |
| GOST R IEC 61165:2019 | Identical |
| BS EN 61165:2006 | Identical |
| CEI EN 61165 : 2007 | Identical |
| EN 61165:2006 | Identical |
| DIN EN 61165:2007-02 | Identical |
| UNE-EN 61165:2006 | Identical |
| CEI 56-38 : 1ED 2000 | Identical |
| UNE 21406:1997 | Identical |
| I.S. EN 50126-1:2017 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
| PD IEC/TR 63039:2016 | Probabilistic risk analysis of technological systems. Estimation of final event rate at a given initial state |
| BS EN 31010:2010 | Risk management. Risk assessment techniques |
| BS EN 61069-5:2016 | Industrial-process measurement, control and automation. Evaluation of system properties for the purpose of system assessment Assessment of system dependability |
| BS EN 61800-5-2:2017 | Adjustable speed electrical power drive systems Safety requirements. Functional |
| CEI EN 61131-6 : 2013 | PROGRAMMABLE CONTROLLERS - PART 6: FUNCTIONAL SAFETY |
| 10/30198892 DC : 0 | BS EN ISO 13849-2 - SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 2: VALIDATION |
| IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
| 13/30273033 DC : 0 | BS EN 1012-3 - COMPRESSORS AND VACUUM PUMPS - SAFETY REQUIREMENTS - PART 3: PROCESS COMPRESSORS |
| CEI EN 60947-5-3 : 2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
| API 689 : 2007 | COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
| BS EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
| BS EN 62502:2011 | Analysis techniques for dependability. Event tree analysis (ETA) |
| BS EN 61907:2010 | Communication network dependability engineering |
| BS EN 61078:2016 | Reliability block diagrams |
| 17/30337986 DC : 0 | BS EN ISO 20815 - PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - PRODUCTION ASSURANCE AND RELIABILITY MANAGEMENT |
| CEI EN 61907 : 2011 | COMMUNICATION NETWORK DEPENDABILITY ENGINEERING |
| 10/30175182 DC : 0 | BS EN 62551 - ANALYSIS TECHNIQUES FOR DEPENDABILITY - PETRI NET MODELLING |
| 08/30193509 DC : DRAFT NOV 2008 | BS EN 61508-2 - FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 2: REQUIREMENTS FOR ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS |
| CEI EN 60300-3-2 : 2006 | DEPENDABILITY MANAGEMENT - PART 3-2: APPLICATION GUIDE - COLLECTION OF DEPENDABILITY DATA FROM THE FIELD |
| CEI EN 62551 : 2013 | ANALYSIS TECHNIQUES FOR DEPENDABILITY - PETRI NET TECHNIQUES |
| CEI EN 50495 : 2011 | SAFETY DEVICES REQUIRED FOR THE SAFE FUNCTIONING OF EQUIPMENT WITH RESPECT TO EXPLOSION RISKS |
| I.S. EN 1012-3:2013 | COMPRESSORS AND VACUUM PUMPS - SAFETY REQUIREMENTS - PART 3: PROCESS COMPRESSORS |
| CEI EN 62308 : 2010 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
| I.S. EN 61163-1:2006 | RELIABILITY STRESS SCREENING - PART 1: REPAIRABLE ASSEMBLIES MANUFACTURED IN LOTS |
| EN IEC 62933-1:2018 | Electrical Energy Storage (EES) systems - Part 1: Vocabulary |
| I.S. EN 61508-7:2010 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 7: OVERVIEW OF TECHNIQUES AND MEASURES |
| BS EN ISO 20815:2010 | Petroleum, petrochemical and natural gas industries. Production assurance and reliability management |
| DIN EN ISO 13849-2:2013-02 | SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 2: VALIDATION (ISO 13849-2:2012) |
| PD IEC/TS 62861:2017 | Guidelines for principal component reliability testing for LED light sources and LED luminaires |
| IEC 62673:2013 | Methodology for communication network dependability assessment and assurance |
| IEC 61069-5:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 5: Assessment of system dependability |
| IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
| CLC/TR 50126-2:2007 | Railway applications - The specification and demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 2: Guide to the application of EN 50126-1 for safety |
| EN 60300-3-2:2005 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
| EN 61131-6:2012 | Programmable controllers - Part 6: Functional safety |
| EN 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
| EN 60300-3-4:2008 | Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements |
| IEC 61511-2:2016 RLV | Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1:2016 |
| EN 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 |
| EN 62673:2013 | Methodology for communication network dependability assessment and assurance |
| EN 61907:2010 | Communication network dependability engineering |
| EN 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
| EN 61800-5-2:2017 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
| EN 62308:2006 | Equipment reliability - Reliability assessment methods |
| EN 61163-1:2006 | Reliability stress screening - Part 1: Repairable assemblies manufactured in lots |
| EN 61025:2007 | Fault tree analysis (FTA) |
| EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
| BS IEC 60300-3-1 : 2003 AMD 15370 | DEPENDABILITY MANAGEMENT - APPLICATION GUIDE - ANALYSIS TECHNIQUES FOR DEPENDABILITY - GUIDE ON METHODOLOGY |
| ISO 20815:2008 | Petroleum, petrochemical and natural gas industries — Production assurance and reliability management |
| BS EN 61511-3:2017 | Functional safety. Safety instrumented systems for the process industry sector Guidance for the determination of the required safety integrity levels |
| PD CEN ISO/TR 12489:2016 | Petroleum, petrochemical and natural gas industries. Reliability modelling and calculation of safety systems |
| CEI EN 62628 : 2013 | GUIDANCE ON SOFTWARE ASPECTS OF DEPENDABILITY |
| BS EN 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
| BS EN 61131-6:2012 | Programmable controllers Functional safety |
| 13/30278416 DC : 0 | BS EN 61800-5-2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-2: SAFETY REQUIREMENTS - FUNCTIONAL |
| BS EN 61163-1:2006 | Reliability stress screening Repairable assemblies manufactured in lots |
| PD CLC/TR 50126-2:2007 | Railway applications. The specification and demonstration of reliability, availability, maintainability and safety (RAMS) Guide to the application of EN 50126-1 for safety |
| I.S. EN 62551:2012 | ANALYSIS TECHNIQUES FOR DEPENDABILITY - PETRI NET TECHNIQUES (IEC 62551:2012 (EQV)) |
| BS EN 61508-6:2010 | Functional safety of electrical/electronic/ programmable electronic safety related systems Guidelines on the application of IEC 61508-2 and IEC 61508-3 |
| I.S. EN 61508-2:2010 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 2: REQUIREMENTS FOR ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS |
| CEI EN 61508-7 : 2011 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETYRELATED SYSTEMS - PART 7: OVERVIEW OF TECHNIQUES AND MEASURES |
| BS EN 62308:2006 | Equipment reliability. Reliability assessment methods |
| ISO/TS 18667:2018 | Space systems — Capability-based Safety, Dependability, and Quality Assurance (SD&QA) programme management |
| EN 50126-1:2017 | Railway Applications - The Specification and Demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 1: Generic RAMS Process |
| I.S. EN 61703:2016 | MATHEMATICAL EXPRESSIONS FOR RELIABILITY, AVAILABILITY, MAINTAINABILITY AND MAINTENANCE SUPPORT TERMS |
| I.S. EN 60300-3-2:2005 | DEPENDABILITY MANAGEMENT - PART 3-2: APPLICATION GUIDE - COLLECTION OF DEPENDABILITY DATA FROM THE FIELD |
| IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
| BS EN ISO 13849-2:2012 | Safety of machinery. Safety-related parts of control systems Validation |
| IEC 61163-1:2006 | Reliability stress screening - Part 1: Repairable assemblies manufactured in lots |
| I.S. EN ISO 13849-2:2012 | SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 2: VALIDATION (ISO 13849-2:2012) |
| I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
| I.S. EN ISO 17776:2016 | PETROLEUM AND NATURAL GAS INDUSTRIES - OFFSHORE PRODUCTION INSTALLATIONS - MAJOR ACCIDENT HAZARD MANAGEMENT DURING THE DESIGN OF NEW INSTALLATIONS (ISO 17776:2016) |
| BS 5760-4:2003 | Reliability of systems, equipment and components Guide to the specification of dependability requirements |
| VDI 4008 Blatt 5:2014-11 | Reliability methodology - State flow graphs |
| VDI 4003:2007-03 | Reliability management |
| VDI 4002 Blatt 2:2011-09 | Reliability Engineer - Requirements for qualification |
| I.S. EN 61078:2016 | RELIABILITY BLOCK DIAGRAMS |
| BS EN 62673:2013 | Methodology for communication network dependability assessment and assurance |
| 15/30324519 DC : 0 | BS EN ISO 14224 - PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
| PD ISO/TS 18667:2018 | Space systems. Capability-based Safety, Dependability, and Quality Assurance (SD&QA) programme management |
| IEC 62933-1:2018 | Electrical energy storage (EES) systems - Part 1: Vocabulary |
| BS EN 61511-2:2017 | Functional safety. Safety instrumented systems for the process industry sector Guidelines for the application of IEC 61511-1 |
| 12/30187831 DC : 0 | BS EN 50126-1 - RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
| CEI EN 62502 : 2012 | ANALYSIS TECHNIQUES FOR DEPENDABILITY - EVENT TREE ANALYSIS (ETA) |
| NF EN 50495 : 2010 | SAFETY DEVICES REQUIRED FOR THE SAFE FUNCTIONING OF EQUIPMENT WITH RESPECT TO EXPLOSION RISKS |
| BS EN 60300-2:2004 | Dependability management Guidelines for dependability management |
| 08/30169896 DC : 0 | BS EN 61907 - GUIDANCE ON COMMUNICATION NETWORK DEPENDABILITY ENGINEERING |
| 08/30193470 DC : DRAFT NOV 2008 | BS EN 61508-6 - FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 6: GUIDELINES ON THE APPLICATION OF IEC 61508-2 AND IEC 61508-3 |
| S.R. CEN ISO/TR 12489:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - RELIABILITY MODELLING AND CALCULATION OF SAFETY SYSTEMS (ISO/TR 12489:2013) |
| 03/118777 DC : DRAFT DEC 2003 | IEC 60812 - ANALYSIS TECHNIQUES FOR SYSTEM RELIABILITY - PROCEDURE FOR FAILURE MODE AND EFFECTS ANALYSIS (FMEA) |
| 02/400715 DC : DRAFT SEP 2002 | BS IEC 60300-2 - DEPENDABILITY MANAGEMENT - PART 2: GUIDELINES FOR DEPENDABILITY MANAGEMENT |
| BS EN 1012-3:2013 | Compressors and vacuum pumps. Safety requirements Process compressors |
| 08/30193478 DC : DRAFT NOV 2008 | BS EN 61508-7 - FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 7: OVERVIEW OF TECHNIQUES AND MEASURES |
| 09/30193520 DC : 0 | BS EN 60947-5-3 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDF) |
| EN 61078 : 1991 | RELIABILITY BLOCK DIAGRAMS (IEC 61078:2016) |
| I.S. EN 50495:2010 | SAFETY DEVICES REQUIRED FOR THE SAFE FUNCTIONING OF EQUIPMENT WITH RESPECT TO EXPLOSION RISKS |
| I.S. EN 60947-5-3:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
| I.S. EN 62673:2013 | METHODOLOGY FOR COMMUNICATION NETWORK DEPENDABILITY ASSESSMENT AND ASSURANCE (IEC 62673:2013 (EQV)) |
| ANSI/ASSE Z690.3 : 2011 | RISK ASSESSMENT TECHNIQUES |
| I.S. EN 61508-6:2010 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 6: GUIDELINES ON THE APPLICATION OF IEC 61508-2 AND IEC 61508-3 |
| I.S. EN ISO 20815:2010 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - PRODUCTION ASSURANCE AND RELIABILITY MANAGEMENT |
| CEN ISO/TR 12489:2016 | Petroleum, petrochemical and natural gas industries - Reliability modelling and calculation of safety systems (ISO/TR 12489:2013) |
| I.S. EN 61025:2007 | FAULT TREE ANALYSIS (FTA) |
| I.S. EN 61800-5-2:2017 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-2: SAFETY REQUIREMENTS - FUNCTIONAL |
| CEI EN 61508-2 : 2011 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS - PART 2: REQUIREMENTS FOR ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS |
| S.R. CLC/TR 50126-2:2007 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 2: GUIDE TO THE APPLICATION OF EN 50126-1 FOR SAFETY |
| IEC 61078:2016 | Reliability block diagrams |
| EN 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| IEC 60947-5-3:2013 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
| ISO 14224:2016 | Petroleum, petrochemical and natural gas industries — Collection and exchange of reliability and maintenance data for equipment |
| GEIA TA HB 0009 : 2013 | RELIABILITY PROGRAM HANDBOOK |
| EN 31010:2010 | Risk management - Risk assessment techniques |
| CEI EN 62059-41 : 2007 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 41: RELIABILITY PREDICTION |
| I.S. EN 61511-3:2017 | FUNCTIONAL SAFETY - SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 3: GUIDANCE FOR THE DETERMINATION OF THE REQUIRED SAFETY INTEGRITY LEVELS |
| ISO/TR 12489:2013 | Petroleum, petrochemical and natural gas industries — Reliability modelling and calculation of safety systems |
| BS EN 61508-2:2010 | Functional safety of electrical/electronic/ programmable electronic safety-related systems Requirements for electrical/electronic/ programmable electronic safety-related systems |
| 15/30310506 DC : 0 | BS EN 61078 - RELIABILITY BLOCK DIAGRAMS |
| 17/30356253 DC : 0 | BS EN 62933-1 - ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 1: TERMINOLOGY |
| PREN ISO 13849-2 : DRAFT 2010 | SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 2: VALIDATION |
| 11/30251566 DC : 0 | BS EN 62628 - GUIDANCE ON SOFTWARE ASPECTS OF DEPENDABILITY |
| BS EN 62059-41:2006 | Electricity metering equipment. Dependability Reliability prediction |
| BS EN 61508-7:2010 | Functional safety of electrical/electronic/ programmable electronic safety related systems Overview of techniques and measures |
| BS PD ISO/TR 12489 : 2013 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - RELIABILITY MODELLING AND CALCULATION OF SAFETY SYSTEMS |
| PREN 50126-1 : DRAFT 2015 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
| BS EN 62551:2012 | Analysis techniques for dependability. Petri net techniques |
| BS EN 60947-5-3:2013 | Low-voltage switchgear and controlgear Control circuit devices and switching elements. Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
| BS EN 61025:2007 | Fault tree analysis (FTA) |
| CEI EN 60300-3-4 : 2010 | DEPENDABILITY MANAGEMENT - PART 3-4: APPLICATION GUIDE - GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS |
| I.S. EN 31010:2010 | RISK MANAGEMENT - RISK ASSESSMENT TECHNIQUES (IEC/ISO 31010:2009 (EQV)) |
| 12/30263521 DC : 0 | BS EN 62673 - METHODOLOGY FOR COMMUNICATION NETWORK DEPENDABILITY ASSESSMENT AND ASSURANCE |
| BS EN 60300-3-2:2005 | Dependability management Application guide. Collection of dependability data from the field |
| BS EN 62628:2012 | Guidance on software aspects of dependability |
| 09/30169892 DC : 0 | BS EN 62502 - ANALYSIS TECHNIQUES FOR DEPENDABILITY - EVENT TREE ANALYSIS |
| PD ISO/TR 10017:2003 | Guidance on statistical techniques for ISO 9001:2000 |
| IEC TR 63039:2016 | Probabilistic risk analysis of technological systems - Estimation of final event rate at a given initial state |
| BS EN 60300-3-1:2004 | Dependability management. Application guide Analysis techniques for dependability. Guide on methodology |
| I.S. EN 61907:2010 | COMMUNICATION NETWORK DEPENDABILITY ENGINEERING |
| BS EN 60812:2006 | Analysis techniques for system reliability. Procedure for failure mode and effects analysis (FMEA) |
| I.S. EN 61069-5:2016 | INDUSTRIAL-PROCESS MEASUREMENT, CONTROL AND AUTOMATION - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 5: ASSESSMENT OF SYSTEM DEPENDABILITY |
| I.S. EN IEC 62933-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 1: VOCABULARY |
| ANSI/ASSE Z690 PACKAGE : 2011 | ANSI/ASSE Z690.1-2011 - VOCABULARY FOR RISK MANAGEMENT; ANSI/ASSE Z690.2-2011 - RISK MANAGEMENT - PRINCIPLES AND GUIDELINES; ANSI/ASSE Z690.3-2011 - RISK ASSESSMENT TECHNIQUES; ISO/ANSI/ASSE/TR-31004-2014 (Z690 TR-2014) RISK MANAGEMENT-GUIDANCE FOR THE IMPLEMENTATION OF ISO 31004 |
| I.S. EN 62502:2010 | ANALYSIS TECHNIQUES FOR DEPENDABILITY - EVENT TREE ANALYSIS (ETA) |
| ISO/TR 10017:2003 | Guidance on statistical techniques for ISO 9001:2000 |
| IEC TR 62036:2007 | Mineral insulating oils - Oxidation stability test method based on differential scanning calorimetry (DSC) |
| I.S. EN 62059-41:2006 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 41: RELIABILITY PREDICTION |
| CEI EN 61078 : 2006 | ANALYSIS TECHNIQUES FOR DEPENDABILITY - RELIABILITY BLOCK DIAGRAM AND BOOLEAN METHODS |
| CEI EN 62673 : 2014 | METHODOLOGY FOR COMMUNICATION NETWORK DEPENDABILITY ASSESSMENT AND ASSURANCE |
| S.R. ISO/TR 10017:2003 | GUIDANCE ON STATISTICAL TECHNIQUES FOR ISO 9001:2000 |
| CEI EN 61025 : 2007 | FAULT TREE ANALYSIS (FTA) |
| EN ISO 20815:2010 | Petroleum, petrochemical and natural gas industries - Production assurance and reliability management (ISO 20815:2008, Corrected version 2009-06-15) |
| IEC 61511-2:2016 | Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1:2016 |
| I.S. EN 62308:2006 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
| IEC 61800-5-2:2016 RLV | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
| BS EN ISO 17776:2016 | Petroleum and natural gas industries. Offshore production installations. Major Accident hazard management during the design of new installations |
| IEC 61907:2009 | Communication network dependability engineering |
| IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
| IEC 61131-6:2012 | Programmable controllers - Part 6: Functional safety |
| IEC/ISO 31010:2009 | Risk management - Risk assessment techniques |
| IEC 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
| IEC 62502:2010 | Analysis techniques for dependability - Event tree analysis (ETA) |
| IEC 62628:2012 | Guidance on software aspects of dependability |
| IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
| IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| ISO 17776:2016 | Petroleum and natural gas industries — Offshore production installations — Major accident hazard management during the design of new installations |
| IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
| IEC 61025:2006 | Fault tree analysis (FTA) |
| IEC 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
| IEC 62059-41:2006 | Electricity metering equipment - Dependability - Part 41: Reliability prediction |
| IEC 60300-2:2004 | Dependability management - Part 2: Guidelines for dependability management |
| EN 62502:2010 | Analysis techniques for dependability - Event tree analysis (ETA) |
| EN ISO 13849-2:2012 | Safety of machinery - Safety-related parts of control systems - Part 2: Validation (ISO 13849-2:2012) |
| EN ISO 17776:2016 | Petroleum and natural gas industries - Offshore production installations - Major Accident hazard management during the design of new installations (ISO 17776:2016) |
| 04/30066208 DC : DRAFT DEC 2004 | ISO 14224 - PETROLEUM AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
| I.S. EN 61511-2:2017 | FUNCTIONAL SAFETY - SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 2: GUIDELINES FOR THE APPLICATION OF IEC 61511-1 |
| CEI EN 60300-3-1 : 2005 | DEPENDABILITY MANAGEMENT - PART 3-1: APPLICATION GUIDE - ANALYSIS TECHNIQUES FOR DEPENDABILITY - GUIDE ON METHODOLOGY |
| I.S. EN 60300-2:2004 | DEPENDABILITY MANAGEMENT - PART 2: GUIDELINES FOR DEPENDABILITY MANAGEMENT |
| IEC 61511-3:2016 | Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels |
| 17/30310522 DC : 0 | BS EN 60812 ED 3.0 - FAILURE MODE AND EFFECTS ANALYSIS (FMEA) |
| PD IEC/TR 62036:2007 | Mineral insulating oils. Oxidation stability test method based on differential scanning calorimetry (DSC) |
| 14/30298031 DC : 0 | BS EN 61069-5 ED 2.0 - INDUSTRIAL-PROCESS MEASUREMENT AND CONTROL - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 5: ASSESSMENT OF SYSTEM DEPENDABILITY |
| 03/108624 DC : DRAFT JULY 2003 | IEC 60300-3-2 - DEPENDABILITY MANAGEMENT - PART 3-2: APPLICATION GUIDE - COLLECTION OF DEPENDABILITY DATA FROM THE FIELD |
| 15/30330403 DC : 0 | BS EN 50126-1 - RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
| BS EN 60300-3-4:2008 | Dependability management Application guide. Guide to the specification of dependability requirements |
| 05/30143456 DC : DRAFT DEC 2005 | IEC 61508-2 - FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY - PART 2: REQUIREMENTS FOR ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY-RELATED SYSTEMS |
| I.S. EN 61131-6:2012 | PROGRAMMABLE CONTROLLERS - PART 6: FUNCTIONAL SAFETY (IEC 61131-6:2012 (EQV)) |
| I.S. EN 61557-15:2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES IN IT SYSTEMS AND EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
| I.S. EN 62628:2012 | GUIDANCE ON SOFTWARE ASPECTS OF DEPENDABILITY (IEC 62628:2012 (EQV)) |
| I.S. EN 60812:2006 | ANALYSIS TECHNIQUES FOR SYSTEM RELIABILITY - PROCEDURE FOR FAILURE MODE AND EFFECTS ANALYSIS (FMEA) |
| I.S. EN 60300-3-4:2008 | DEPENDABILITY MANAGEMENT - PART 3-4: APPLICATION GUIDE - GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS |
| I.S. EN 60300-3-1:2004 | DEPENDABILITY MANAGEMENT - PART 3-1: APPLICATION GUIDE - ANALYSIS TECHNIQUES FOR DEPENDABILITY - GUIDE ON METHODOLOGY |
| IEC 62551:2012 | Analysis techniques for dependability - Petri net techniques |
| IEC 62308:2006 | Equipment reliability - Reliability assessment methods |
| BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
| ISO 13849-2:2012 | Safety of machinery — Safety-related parts of control systems — Part 2: Validation |
| BS EN 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
| IEC TS 62861:2017 | Guidelines for principal component reliability testing for LED light sources and LED luminaires |
| IEC 60300-3-4:2007 | Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements |
| EN 1012-3:2013 | Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors |
| EN 62551:2012 | Analysis techniques for dependability - Petri net techniques |
| EN 61511-2:2017 | Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1 |
| EN 61069-5:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 5: Assessment of system dependability |
| EN 61511-3:2017 | Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels |
| EN 60947-5-3:2013 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
| EN 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures |
| EN 62628:2012 | Guidance on software aspects of dependability |
| EN 60300-3-1:2004 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
| EN 62059-41:2006 | Electricity metering equipment - Dependability - Part 41: Reliability prediction |
| EN 60300-2:2004 | Dependability management - Part 2: Guidelines for dependability management |
| IEC 61511-3:2016 RLV | Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels |
| EN 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
| UNE-EN 62551:2014 | Analysis techniques for dependability - Petri net techniques |
| UNE-EN 31010:2011 | Risk management - Risk assessment techniques |
| UNE-EN 61907:2013 | Communication network dependability engineering |
| UNE-EN 62628:2015 | Guidance on software aspects of dependability |
| UNE-EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
| UNE-EN 61508-7:2011 | Functional safety of electrical/electronic/programmable electronic safety-related systems -- Part 7: Overview of techniques and measures |
| UNE-EN 61508-2:2011 | Functional safety of electrical/electronic/programmable electronic safety-related systems -- Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
| UNE-EN 60947-5-3:2014 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
| UNE-EN 61508-6:2011 | Functional safety of electrical/electronic/programmable electronic safety-related systems -- Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 |
| UNE-EN 60300-3-4:2011 | Dependability management -- Part 3-4: Application guide - Guide to the specification of dependability requirements |
| CEI EN 60812 : 2006 | ANALYSIS TECHNIQUES FOR SYSTEM RELIABILITY - PROCEDURE FOR FAILURE MODE AND EFFECTS ANALYSIS (FMEA) |
| CEI CLC/TR 50506-2 : 2011 | RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - APPLICATION GUIDE FOR EN 50129 - PART 2: SAFETY ASSURANCE |
| CEI EN 61557-15 : 2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES IN IT SYSTEMS AND EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
| UNE-EN ISO 13849-2:2013 | Safety of machinery - Safety-related parts of control systems - Part 2: Validation (ISO 13849-2:2012) |
| CEI EN 61508-6 : 2011 | FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETYRELATED SYSTEMS - PART 6: GUIDELINES ON THE APPLICATION OF IEC 61508-2 AND IEC 61508-3 |
| CEI CLC/TR 50126-2 : 2008 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 2: GUIDE TO THE APPLICATION OF EN 50126-1 FOR SAFETY |
| VDE 0050-1:2010-11 | RISK MANAGEMENT - RISK ASSESSMENT TECHNIQUES |
| IEC 61025:2006 | Fault tree analysis (FTA) |
| IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| IEC 61078:2016 | Reliability block diagrams |
| IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
| AS/NZS IEC 61703:2020 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
| AS/NZS IEC 31010:2020 | Risk management - Risk assessment techniques |
| IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
| AS/NZS IEC 60812:2020 | Failure modes and effects analysis (FMEA and FMECA) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.