• Shopping Cart
    There are no items in your cart

IEC 61952:2008

Current

Current

The latest, up-to-date edition.

Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

27-05-2008

€197.53
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Identification
6 Environmental conditions
7 Transport, storage and installation
8 Tolerances
9 Classification of tests
   9.1 Design tests
   9.2 Type tests
   9.3 Sample tests
   9.4 Routine tests
10 Design tests
   10.1 General
   10.2 Test specimens for IEC 62217
        10.2.1 Tests on interfaces and connections of end fittings
        10.2.2 Tracking and erosion test
        10.2.3 Tests on core material
   10.3 Product specific pre-stressing for IEC 62217 tests on
        interfaces and connections of end fittings
        10.3.1 Thermal-mechanical pre-stressing
   10.4 Assembled core load tests
        10.4.1 Test for the verification of the maximum design
               cantilever load (MDCL)
        10.4.2 Tensile load test
11 Type tests
   11.1 Electrical tests
        11.1.1 Vertical mounting arrangement
        11.1.2 Horizontal mounting arrangement
   11.2 Mechanical tests
        11.2.1 Cantilever failing load test
12 Sample tests
   12.1 General rules
   12.2 Verification of dimensions (E1 + E2)
   12.3 Galvanizing test (E1 + E2)
   12.4 Verification of the SCL (E1)
        12.4.1 Test procedure
        12.4.2 Acceptance criteria
   12.5 Re-testing procedure
13 Routine tests
   13.1 Tensile load test
   13.2 Visual examination
Annex A (informative) Notes on the mechanical loads
        and tests
Annex B (informative) Determination of the equivalent
        bending moment caused by combined loads
Bibliography

IEC 61952:2008 applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core. The object of this standard is to
- define the terms used,
- prescribe test methods,
- prescribe acceptance or failure criteria.
This standard does not include requirements dealing with the choice of insulators for specific operating conditions. This edition includes the following significant technical changes with respect to the previous edition:
- removal of tests procedures now given in IEC 62217;
- inclusion of clauses on tolerances, environmental conditions, transport, storage and installation;
- changes in the parameters determining the need to repeat design and type tests; and
- modification of the specification of load application in bending tests to simplify testing.

Committee
TC 36
DevelopmentNote
Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
54
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
NEN EN IEC 61952 : 2008 Identical
I.S. EN 61952:2008 Identical
PN EN 61952 : 2010 Identical
VDE 0441-200 : 2009 Identical
EN 61952:2008 Identical
SN EN 61952 : 2003 Identical
NF EN 61952 : 2008 Identical
CEI EN 61952 : 2009 Identical
BS EN 61685:2002 Identical
BS EN IEC 60794-2-30:2019 Identical
DIN EN 61952 : 2009 Identical
BS EN 61952:2008 Identical
UNE-EN 61952:2010 Identical

CEI EN 62231 : 2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
PD IEC/TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
NF EN 62621 : 2017 AMD 1 2018 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
NF EN 50151 : 2004 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
EN 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
EN 50151 : 2003 COR 2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
NBR 7282 : 2011 HIGH-VOLTAGE FUSES - EXPULSION TYPE FUSES - REQUIREMENTS AND TEST METHODS
EN 50423-1:2005 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV - Part 1: General requirements - Common specifications
I.S. EN 50151:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
11/30215604 DC : 0 BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 62621 : 2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS (IEC 62621:2011)
I.S. EN 62231:2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1 000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
ANSI C29.11 : 2012 COMPOSITE SUSPENSION INSULATORS FOR OVERHEARD TRANSMISSION LINES - TESTS
BS EN 50423-1:2005 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV General requirements. Common specifications
BS EN 50341-2-4:2016 Overhead electrical lines exceeding AC 1 kV National Normative Aspects (NNA) for Germany (based on EN 50341-1:2012)
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
02/206403 DC : DRAFT MAY 2002 IEC 62231. ED.1.0 - COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UPTO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
IEC TS 62896:2015 Hybrid insulators for a.c. and d.c. for high-voltage applications - Definitions, test methods and acceptance criteria
PD IEC/TS 62896:2015 Hybrid insulators for a.c. and d.c. high-voltage applications. Definitions, test methods and acceptance criteria
BS EN 62231:2007 Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV. Definitions, test methods and acceptance criteria
I.S. EN 50423-1:2005 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV UP TO AND INCLUDING AC 45 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
EN 50341-2-4:2016 Overhead electrical lines exceeding AC 1 kV - Part 2-4: National Normative Aspects (NNA) for Germany (based on EN 50341-1:2012)
BS EN 50151:2003 Railway applications. Fixed installations. Electric traction. Special requirements for composite insulators
IEC TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
IEC 62621:2011 Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
UNE-EN 62621:2016 Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems
IEC 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
17/30337860 DC : 0 BS EN 61952-1 - INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - PART 1: DEFINITIONS, END FITTINGS AND DESIGNATIONS
I.S. EN 62621:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
I.S. EN 50341-2-4:2016 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 2-4: NATIONAL NORMATIVE ASPECTS (NNA) FOR GERMANY (BASED ON EN 50341-1:2012)
EN 62621:2016/A1:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS

IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
ISO 3452:1984 Non-destructive testing — Penetrant inspection — General principles
IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
IEC GUIDE 111:2004 Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.