IEC 62040-3:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
14-03-2011
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
5 Electrical conditions, performance and declared values
6 UPS tests
Annex A (informative) - Uninterruptible power system
(UPS) configurations
Annex B (informative) - Topologies - Uninterruptible
power system (UPS)
Annex C (informative) - UPS switch applications
Annex D (informative) - Purchaser specification guidelines
Annex E (normative) - Reference non-linear load
Annex F (informative) - Information on backfeed protection
Annex G (normative) - Input mains failure - Test method
Annex H (informative) - Dynamic output performance -
Measurement techniques
Annex I (informative) - UPS Efficiency values
Annex J (normative) - UPS efficiency - Methods of
measurement
Annex K (informative) - UPS functional availability
Bibliography
IEC 62040-3:2011 applies to movable, stationary and fixed electronic uninterruptible power systems (UPS) that deliver single or three phase fixed frequency a.c. output voltage not exceeding 1 000 V a.c. and that incorporate an energy storage system, generally connected through a d.c. link. This standard is intended to specify performance and test requirements of a complete UPS and not of individual UPS functional units. The individual UPS functional units are dealt with in IEC publications referred to in the bibliography that apply so far that they are not in contradiction with this standard. The primary function of the UPS covered by this standard is to ensure continuity of an a.c. power source. The UPS may also serve to improve the quality of the power source by keeping it within specified characteristics. UPS have been developed over a wide range of power, from less than hundred watts to several megawatts, to meet requirements for availability and quality of power to a variety of loads. Refer to Annexes A and B for information on typical UPS configurations and topologies. This standard also covers UPS test and performance when power switches form integral part of a UPS and are associated with its output. Included are interrupters, bypass switches, isolating switches, and tie switches. These switches interact with other functional units of the UPS to maintain continuity of load power. This standard does not cover:
- conventional a.c. input and output distribution boards or d.c. boards and their associated switches (e.g. switches for batteries, rectifier output or inverter input);
- stand-alone static transfer systems covered by IEC 62310-3;
- systems wherein the output voltage is derived from a rotating machine.
NOTE 1 This standard recognises that power availability to information technology (IT) equipment represents a major UPS application. The UPS output characteristics specified in this standard are therefore also aimed at ensuring compatibility with the requirements of IT equipment. This, subject any limitation stated in the manufacturer's declaration, includes requirements for steady state and transient voltage variation as well as for the supply of both linear and non-linear load characteristics of IT equipment.
NOTE 2 Test loads specified in this standard simulate both linear and non-linear load characteristics. Their use is prescribed with the objective of verifying design and performance, as declared by the manufacturer, and also of minimising any complexity and energy consumption during the tests.
NOTE 3 This standard is aimed at 50 Hz and 60 Hz applications but does not exclude other frequency applications within the domain of IEC 60196. This is subject to an agreement between manufacturer and purchase in respect to any particular requirements arising.
NOTE 4 Single phase and three-phase voltage UPS covered by this standard include without limitation UPS supplying single-phase, two-wire; single-phase, three-wire; two-phase, three-wire, three-phase, three-wire and three-phase, four-wire loads.
This second edition cancels and replaces first edition published in 1999 and constitutes a technical revision. The significant technical changes are:
- reference test load - definition and application revised (3.3.5 and 6.1.1.3);
- test schedule - presented as a single table grouped by revised type and routine tests (see 6.1.6, Table 3);
- dynamic output voltage performance characteristics - guidance to measure - addition (Annex H);
- UPS efficiency - requirements and methods of measure - addition (Annexes I and J);
- functional availability - guidance for UPS reliability integrity level classification - addition (Annex K).
Committee |
TC 22/SC 22H
|
DevelopmentNote |
Supersedes IEC 60146-4, IEC 60146-5. (03/2001) Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
218
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 62040-3 : 2012 | Identical |
NF EN 62040-3 : 2012 | Identical |
NBN EN 62040-3 : 2011 | Identical |
NEN EN IEC 62040-3 : 2011 | Identical |
I.S. EN 62040-3:2011 | Identical |
PN EN 62040-3 : 2011 | Identical |
DIN EN 62040-3 : 2011 | Identical |
VDE 0558-530:2011 | Identical |
AS IEC 62040.3-2012 | Identical |
UNE-EN 62040-3:2011 | Identical |
BIS IS 16242-3 : 2014 | Identical |
BS EN 62040-3:2011 | Identical |
CEI EN 62040-3 : 2015 | Identical |
EN 62040-3:2011 | Identical |
PNE-FprEN 62040-3 | Identical |
NEN IEC 62040-3 : 1999 | Identical |
SN EN 62040-3 : 2001 | Identical |
09/30214359 DC : 0 | BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
09/30214220 DC : 0 | BS IEC TR 61000-2-5 ED - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-5: ENVIRONMENT - CLASSIFICATION OF ELECTROMAGNETIC ENVIRONMENTS |
BS EN 50533 : 2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
CEI EN 62040-4 : 2014 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING |
BS EN 62040-1 : 2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
CSA C813.1 : 2014 | PERFORMANCE TEST METHOD FOR UNINTERRUPTIBLE POWER SUPPLIES |
S.R. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
06/30158289 DC : 0 | BS EN 62040-1 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
EN 62040-4:2013 | Uninterruptible power systems (UPS) - Part 4: Environmental aspects - Requirements and reporting |
EN 62040-1-2:2003/corrigendum:2004 | |
EN 50600-4-1:2016 | Information technology - Data centre facilities and infrastructures - Part 4-1: Overview of and general requirements for key performance indicators |
06/30157062 DC : 0 | BS EN 62310-3 - STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
NF EN 62310-3 : 2008 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
BS ISO/IEC 30134-1:2016+A1:2018 | Information technology. Data centres. Key performance indicators Overview and general requirements |
NF EN 62040-2 : 2006 | |
11/30231694 DC : 0 | BS EN 62040-4 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING |
CEI EN 62040-2 : 2006 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
I.S. EN 62310-1:2005 | STATIC TRANSFER SYSTEMS (STS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
ISO/IEC 30134-1:2016 | Information technology Data centres Key performance indicators Part 1: Overview and general requirements |
BIS IS 16242-1 : 2014 AMD 1 2018 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
EN IEC 62909-1:2018 | Bi-directional grid-connected power converters - Part 1: General requirements |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
I.S. EN 62040-1-2:2004 | |
I.S. EN 62040-1:2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008 (EQV)) |
UNE-HD 60364-5-56:2010 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
PD IEC/TR 60146-1-2:2011 | Semiconductor converters. General requirements and line commutated converters Application guide |
I.S. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV)) |
PD IEC/TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) Environment. Description and classification of electromagnetic environments |
I.S. EN IEC 62909-1:2018 | BI-DIRECTIONAL GRID-CONNECTED POWER CONVERTERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62040-4:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING (IEC 62040-4:2013 (EQV)) |
IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
ISO 14224:2016 | Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment |
BS EN 62310-3:2008 | Static transfer systems (STS) Method for specifying performance and test requirements |
BS EN 62040-4:2013 | Uninterruptible power systems (UPS) Environmental aspects. Requirements and reporting |
14/30292140 DC : 0 | BS EN 62040-2 ED3.0 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS (EMC) |
BS EN 50600-4-1:2016 | Information technology. Data centre facilities and infrastructures Overview of and general requirements for key performance indicators |
I.S. EN 62040-1-1:2004 | |
I.S. EN 50533:2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
I.S. EN 50600-4-1:2016 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-1: OVERVIEW OF AND GENERAL REQUIREMENTS FOR KEY PERFORMANCE INDICATORS |
I.S. EN 62310-3:2008 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS |
CEI EN 62310-1 : 2006 | STATIC TRANSFER SYSTEMS (STS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
IEC TR 60146-1-2:2011 | Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide |
I.S. EN 62040-2:2006 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
IEC 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
IEC 62040-1-1:2002 | Uninterruptible power systems (UPS) - Part 1-1: General and safety requirements for UPS used in operator access areas |
IEC 62040-4:2013 | Uninterruptible power systems (UPS) - Part 4: Environmental aspects - Requirements and reporting |
IEC 62040-1-2:2002 | Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations |
UNE-EN 50533:2012 | Railway applications - Three-phase train line voltage characteristics. |
CSA C812 : 2016 | ENERGY PERFORMANCE OF LARGE BATTERY CHARGER SYSTEMS |
BS EN 62040-1-1:2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
PREN 50533 : DRAFT 2009 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
HD 60364-5-56:2010/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
NF EN 62040-1 : 2009 AMD 1 2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
BS EN 62040-2:2006 | Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements |
CEI EN 62310-3 : 2010 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS |
OVE/ONORM EN 62040-2 : 2006 | |
IEC 62909-1:2017 | Bi-directional grid connected power converters - Part 1: General requirements |
NF EN 62040-4 : 2014 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
IEC 62040-2:2016 RLV | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC TR 61000-2-5:2017 RLV | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
BS EN 62040-1-2:2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
EN 62040-1-1:2003/corrigendum:2004 | |
EN 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
EN 62040-2:2006/corrigendum:2006 | |
EN 50533 : 2011 AMD 1 2016 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
EN 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
CAN/CSA-ISO/IEC 30134-1:18 | Information technology — Data centres — Key performance indicators — Part 1: Overview and general requirements (Adopted ISO/IEC 30134-1:2016, first edition, 2016-03-15) |
PIP ELSAP04 : 2015 | UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEM SPECIFICATION |
CAN/CSA-C381.2-17 | Energy performance of battery-charging systems and uninterruptible power supplies |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
IEC 60038:2009 | IEC standard voltages |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
AS IEC 62040.2:2019 | Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements |
IEC 60196:2009 | IEC standard frequencies |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60034-22:2009 | Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
SA TR IEC 61000.2.5:2019 | Electromagnetic compatibility (EMC) Environment - Description and classification of electromagnetic environments |
IEC 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60146-2:1999 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC TS 61000-3-4:1998 | Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60050-111:1996 | International Electrotechnical Vocabulary (IEV) - Part 111: Physics and chemistry |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
IEC TR 61000-2-8:2002 | Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
ISO 7779:2010 | Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.