IEC 62423:2009
Current
The latest, up-to-date edition.
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
20-11-2009
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. IEC 62423:2009 specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes from the first edition are as follows:
- requirements and tests for Type F RCD have been introduced;
- requirements and test for two-pole Type B RCD have been introduced;
- new additional requirements and tests for Type B RCDs have been introduced to cover requirements for Type F too. The contents of the corrigendum 1 of December 2011 have been included in this copy and the corrigendum 2 of July 2021 applies to the French language only.
Committee |
TC 23/SC 23E
|
DevelopmentNote |
To be read in conjunction with IEC 61008-1 and IEC 61009-1. (05/2007) Stability Date: 2020. (12/2017)
|
DocumentType |
Standard
|
Pages |
75
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 62423 : 2013 | Identical |
UNE-EN 62423:2013 | Identical |
SN EN 62423 : 2012 | Identical |
I.S. EN 62423:2012&A11:2021 | Identical |
I.S. EN 62423:2012/AC:2021-09 | Identical |
CEI EN 62423 : 2013 | Identical |
NF EN 62423 : 2013 | Identical |
VDE 0664-40 : 2013 | Identical |
NBN EN 62423 : 2013 | Identical |
GOST IEC 62423 : 2013 | Identical |
UNE-HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
BS 7909:2011 | Code of practice for temporary electrical systems for entertainment and related purposes |
S.R. HD 60364-5-537:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
NF EN 61439-3 : 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: DISTRIBUTION BOARDS INTENDED TO BE OPERATED BY ORDINARY PERSONS (DBO) |
S.R. HD 60364-4-41:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
S.R. HD 60364-4-42:2011 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
CSA C22.2 No. 61980-1 : 2016 | ELECTRIC VEHICLE WIRELESS POWER TRANSFER (WPT) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
IEC 61851-1:2017 | Electric vehicle conductive charging system - Part 1: General requirements |
IEC 62752:2016 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
BS EN 62477-1 : 2012 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012) |
EN 61439-3 : 2012 COR 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: DISTRIBUTION BOARDS INTENDED TO BE OPERATED BY ORDINARY PERSONS (DBO) (IEC 61439-3:2012) |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
EN 62606:2013/A1:2017 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017) |
BS IEC 62873-2:2016 | Residual current operated circuit-breakers for household and similar use Residual current devices (RCDs). Vocabulary |
12/30248611 DC : 0 | BS EN 62606 - GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (AFDD) |
I.S. EN 62477-1:2012 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL |
I.S. EN 62606:2013 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
UNE-HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
S.R. HD 60364-7-712:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-712: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - PHOTOVOLTAIC (PV) SYSTEMS |
I.S. EN 63024:2018 | REQUIREMENTS FOR AUTOMATIC RECLOSING DEVICES (ARDS) FOR CIRCUIT-BREAKERS, RCBOS AND RCCBS FOR HOUSEHOLD AND SIMILAR USES |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
16/30339801 DC : 0 | BS EN 63052 - POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICES FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
IEC 62873-2:2016 | Residual current operated circuit-breakers for household and similar use - Part 2: Residual current devices (RCDs) - Vocabulary |
I.S. EN 62752:2016/AC:2019-03 | IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD) |
CEI EN 62606 : 2014 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
IEC TR 62710:2015 | Residual current devices (RCDs) associated with additional functions(s) |
IEC 60755:2017 | General safety requirements for residual current operated protective devices |
UNE-HD 60364-7-712:2017 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
UNE-HD 60364-5-53:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear |
UNE-EN 61439-3:2012 | Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
15/30259978 DC : 0 | BS EN 62477-2 - SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 2: POWER ELECTRONIC CONVERTERS FROM 1000 V A.C. OR 1500 V D.C. UP TO 36 KV A.C. OR 54 KV D.C. |
EN 63024:2018 | Requirements for automatic reclosing devices (ARDs) for circuit-breakers, RCBOs and RCCBs for household and similar uses |
HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
I.S. EN 61439-3:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: DISTRIBUTION BOARDS INTENDED TO BE OPERATED BY ORDINARY PERSONS (DBO) (IEC 61439-3:2012 (EQV)) |
IEC 60364-7-721:2017 | Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans |
S.R. HD 60364-7-722:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES |
IEC 62477-1:2012+AMD1:2016 CSV | Safety requirements for power electronic converter systems and equipment - Part 1: General |
EN 62752:2016 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
IEC 61439-3:2012 | Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
HD 60364-5-537:2016/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
14/30298271 DC : 0 | BS EN 60364-7-722 ED 1.0 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLY OF ELECTRIC VEHICLES |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
I.S. HD 50573-5-57:2014 | CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL |
15/30328943 DC : 0 | BS EN 63024 ED1.0 - REQUIREMENTS FOR AUTOMATIC RECLOSING DEVICES (ARD[S]) FOR CIRCUIT BREAKERS- RCBO[S],RCCB[S] FOR HOUSEHOLD AND SIMILAR USES |
S.R. HD 60364-5-53:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 62606:2013 | General requirements for arc fault detection devices |
HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
UNE-EN 62752:2017 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
IEC 62840-2:2016 | Electric vehicle battery swap system - Part 2: Safety requirements |
IEC TS 62257-5:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 5: Protection against electrical hazards |
IEC 60364-7-722:2015 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
IEC 63024:2017 | Requirements for automatic reclosing devices (ARDs) for circuit breakers, RCBOs-RCCBs for household and similar uses |
EN 62477-1:2012/A1:2017 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012/A1:2016) |
PD IEC/TS 62257-5:2015 | Recommendations for renewable energy and hybrid systems for rural electrification Protection against electrical hazards |
HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
HD 60364-7-712:2016 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
IEC 60364-7-712:2017 RLV | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
UNE-HD 60364-5-537:2017 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching |
CEI EN IEC 61439-2:2021 | Low-voltage switchgear and controlgear assemblies Part 2: Power switchgear and controlgear assemblies |
I.S. EN IEC 61543:2023/A11:2023 | Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
CEI EN IEC 61543:2023 | Residual current-operated protective devices (RCDs) for household and similar use. Electromagnetic compatibility |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 61009-2-1:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 61009-2-2:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-2: Applicability of the general rules to RCBO's functionally dependent on line voltage |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
IEC 61008-2-2:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-2: Applicability of the general rules to RCCB's functionally dependent on line voltage |
IEC 61008-2-1:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage |
IEC TS 60479-2:2007 | Effects of current on human beings and livestock - Part 2: Special aspects |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.