ASTM D 1533 : 2012 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
17-11-2020
English
01-12-2012
CONTAINED IN VOL. 10.03, 2015 Defines the measurement of water present in insulating liquids by coulometric Karl Fischer titration.
Committee |
D 27
|
DocumentType |
Redline
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This test method covers the measurement of water present in insulating liquids by coulometric Karl Fischer titration. This test method is used commonly for test specimens below 100 % relative saturation of water in oil. The coulometric test method is known for its high degree of sensitivity (typically 10 μg H2O). This test method requires the use of equipment specifically designed for coulometric titration.
1.2This test method recommends the use of commercially available coulometric Karl Fischer titrators and reagents.
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see 8.1 and A2.1.
IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) |
IEEE C57.152-2013 | IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors |
MIL V 51239 : B | VEGETATION CONTROL AGENT, ORANGE |
ASTM E 203 : 2016 : REDLINE | Standard Test Method for Water Using Volumetric Karl Fischer Titration |
ASTM D 3277 : 1995 | Standard Test Methods for Moisture Content of Oil-Impregnated Cellulosic Insulation |
IEEE C57.147-2008 | IEEE Guide for Acceptance and Maintenance of Natural Ester Fluids in Transformers |
IEEE C57.637-2015 | IEEE Guide for the Reclamation of Mineral Insulating Oil and Criteria for Its Use |
ASTM F 1013 : 1992 | Practice for Determining the Performance of a Liquid/Liquid Separator System Employing a Single-Pass, Constant-Rate, Non-Solids Test (Withdrawn 2001) |
IEEE DRAFT 62 : 200D8 | GUIDE FOR DIAGNOSTIC FIELD TESTING OF ELECTRIC POWER APPARATUS |
ASTM D 3613 : 1998 | Standard Practice for Sampling Insulating Liquids for Gas Analysis and Determination of Water Content (Withdrawn 2007) |
ASTM D 2225 : 2004 : R2012 | Standard Test Methods for Silicone Fluids Used for Electrical Insulation |
ASTM D 6871 : 2017 | Standard Specification for Natural (Vegetable Oil) Ester Fluids Used in Electrical Apparatus |
NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
ASHRAE 35 : 2014 | METHOD OF TESTING DESICCANTS FOR REFRIGERANT DRYING |
ASHRAE GUIDELINE 40 : 2017 | REFRIGERATION OIL DESCRIPTION |
ASTM D 3277 : 1995 : EDT 1 | Standard Test Methods for Moisture Content of Oil-Impregnated Cellulosic Insulation |
MIL-C-47220 Revision B:1985 | COOLANT FLUID, DIELECTRIC |
ASTM D 2225 : 2004 | Standard Test Methods for Silicone Fluids Used for Electrical Insulation |
DOD-I-51064 Revision D:1979 | |
NETA ATS : 2017 | ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS |
ASTM D 4652 : 2005 : R2012 | Standard Specification for Silicone Fluid Used for Electrical Insulation |
IEEE C57.100-2011 | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers |
ASTM D 6181 : 2003 | Standard Test Method for Measurement of Turbidity in Mineral Insulating Oil of Petroleum Origin (Withdrawn 2012) |
IEEE C57.111 : 1989 | GUIDE FOR ACCEPTANCE OF SILICONE INSULATING FLUID AND ITS MAINTENANCE IN TRANSFORMERS |
ASTM D 6813 : 2002 : REV A : R2007 | Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps |
ASTM D 6813 : 2002 | Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps |
ASTM D 6813 : 2002 : REV A : R2013 | Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps (Withdrawn 2015) |
ASTM D 6813 : 2002 : REV A | Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps |
ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
ASTM D 1676 : 2017 : REDLINE | Standard Test Methods for Film-Insulated Magnet Wire |
IEEE 637-1985 | IEEE Guide for the Reclamation of Insulating Oil and Criteria for Its Use |
IEEE C57.125-2015 | IEEE Guide for Failure Investigation, Documentation, Analysis, and Reporting for Power Transformers and Shunt Reactors |
IEEE 62-1995 | IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors |
ASTM D 3277 : 1995 : R2001 : EDT 1 | Standard Test Methods for Moisture Content of Oil-Impregnated Cellulosic Insulation (Withdrawn 2010) |
ASTM D 5222 : 2016 : REDLINE | Standard Specification for High Fire-Point Mineral Electrical Insulating Oils |
GOST 849:2018 | Primary nickel. SpecificationsE |
IEEE C57.106-2006 | IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment |
CAN/CSA-C50-14 (R2018) | Mineral insulating oil, electrical, for transformers and switches |
ASTM D 2428 : 1992 | Standard Test Method for Simulative Recirculating System Testing of Aerospace Hydraulic Fluids (Withdrawn 1997) |
ASTM D 7785 : 2012 | Standard Test Method for Water in Lint Cotton by Oven Evaporation Combined with Volumetric Karl Fischer Titration |
ASTM D 4652 : 2005 | Standard Specification for Silicone Fluid Used for Electrical Insulation |
ASTM D 923 : 2015 : REDLINE | Standard Practices for Sampling Electrical Insulating Liquids |
ASTM D 6224 : 2016 : REDLINE | Standard Practice for In-Service Monitoring of Lubricating Oil for Auxiliary Power Plant Equipment |
IEC 60814:1997 | Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration |
ASTM D 923 : 2015 : REDLINE | Standard Practices for Sampling Electrical Insulating Liquids |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.