• Shopping Cart
    There are no items in your cart

BS EN 50379-3:2012

Current

Current

The latest, up-to-date edition.

Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2012

€156.59
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Test methods and performance requirements
Bibliography

Defines apparatus designed for checking the performance of heating appliances by measuring flue gas parameters of gas fired heating appliances for domestic residential and commercial applications.

Committee
EXL/31/1
DevelopmentNote
Supersedes 02/203343 DC. (09/2004) Supersedes BS 7927(1998). (04/2007)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard covers apparatus designed for checking the performance of heating appliances by measuring flue gas parameters of gas fired heating appliances for domestic residential and commercial applications.

The apparatus may consist of different functional modules which may be tested separately for complying with this standard, and will be combined in different ways according to the different applications. Part 1 of EN 50379 specifies the general requirements and is supplemented by the requirements in EN 50379-2 and/or EN 50379-3.

This European Standard specifies the performance requirements of portable spot reading apparatus designed to detect specific combustion flue gas parameters, such as concentration of gaseous compounds, temperature and/or pressure, to be used to decide if maintenance for the appliance is required and for adjusting the appliance during maintenance.

This European Standard excludes apparatus for

  • checking appliances using fuels other than gas,

  • continuous emission, safety monitoring and control, and

  • use in vessels with an international load line.

NOTE 1 When this apparatus is used in industrial premises, national regulations should be observed.

NOTE 2 Apparatus may contain functional modules which are not covered by this standard e.g. measurement of smoke spot number (see EN 267:2009+A1:2011, Annex A) and/or measurement of indoor ambient air (see EN 50543).

Standards Relationship
NBN EN 50379-3 : 2012 Identical
NF EN 50379-3 : 2012 Identical
NEN EN 50379-3 : 2012 Identical
I.S. EN 50379-3:2012 Identical
SN EN 50379-3 : 2012 Identical
DIN EN 50379-3 : 2013 Identical
UNE-EN 50379-3:2013 Identical
EN 50379-3:2012 Identical

BS 7967-4:2007 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances
10/30213917 DC : 0 BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
09/30205734 DC : 0 BS 5864 - INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED HEAT INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION
07/30150793 DC : 0 BS 5440-1 - FUELING AND VENTILATION FOR GAS APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET (1ST, 2ND AND 3RD FAMILY GASES) - PART 1: SPECIFICATION FOR INSTALLATION OF GAS APPLIANCES TO CHIMNEYS AND FOR MAINTENANCE OF CHIMNEYS
BS 6172(2010) : 2010 SPECIFICATION FOR INSTALLATION, SERVICING AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES)
BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
13/30261683 DC : 0 BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
10/30204527 DC : 0 BS 6172 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES)
BS 7967-5:2010 Carbon monoxide in dwellings and other premises and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in non-domestic premises for the measurement of carbon monoxide and carbon dioxide levels and the determination of combustion performance
08/30166539 DC : DRAFT JULY 2008 BS 6798 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 7967:2015 Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fired appliances
BS 5871-2:2005 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases)
BS 6798:2009 Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 5440-1:2008 Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys
BS 5871-3:2005 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Decorative fuel effect gas appliances of heat input not exceeding 20 kW (2nd and 3rd family gases)
BS 6798:2014 Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 7967-1:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation
BS 7967-3:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers
08/30166742 DC : DRAFT JUNE 2008 BS 7967-5 - MEASUREMENT OF CARBON MONOXIDE, CARBON DIOXIDE AND THE COMBUSTION PERFORMANCE OF GAS-FIRED EQUIPMENT - PART 5: GUIDE FOR USING ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS IN NON-DOMESTIC PREMISES FOR THE MEASUREMENT OF CARBON MONOXIDE AND CARBON DIOXIDE IN INDOOR AIR AND THE DETERMINATION OF COMBUSTION PERFORMANCE
06/30112198 DC : DRAFT AUG 2006 BS 7967-4 - CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF GAS-FIRED APPLIANCES - PART 4: GUIDE FOR USING ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS AS PART OF THE PROCESS OF SERVICING AND MAINTENANCE OF GAS-FIRED APPLIANCES
BS 7967-2:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance
09/30166542 DC : 0 BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 8660-1:2011 Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
14/30258585 DC : 0 BS 7967 - GUIDE FOR THE USE OF ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS FOR THE MEASUREMENT OF CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF DOMESTIC GAS FIRED APPLIANCES
BS 5864:2010 Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification

EN 50270:2015 Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
EN 60359:2002 Electrical and electronic measurement equipment - Expression of performance
(INVALID RECORD) EN 50543:2011/AC:2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50271:2010 Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies
IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
EN 50379-1:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.