BS EN 50379-3:2012
Current
The latest, up-to-date edition.
Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
Hardcopy , PDF
English
30-04-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Test methods and performance requirements
Bibliography
Defines apparatus designed for checking the performance of heating appliances by measuring flue gas parameters of gas fired heating appliances for domestic residential and commercial applications.
Committee |
EXL/31/1
|
DevelopmentNote |
Supersedes 02/203343 DC. (09/2004) Supersedes BS 7927(1998). (04/2007)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard covers apparatus designed for checking the performance of heating appliances by measuring flue gas parameters of gas fired heating appliances for domestic residential and commercial applications.
The apparatus may consist of different functional modules which may be tested separately for complying with this standard, and will be combined in different ways according to the different applications. Part 1 of EN 50379 specifies the general requirements and is supplemented by the requirements in EN 50379-2 and/or EN 50379-3.
This European Standard specifies the performance requirements of portable spot reading apparatus designed to detect specific combustion flue gas parameters, such as concentration of gaseous compounds, temperature and/or pressure, to be used to decide if maintenance for the appliance is required and for adjusting the appliance during maintenance.
This European Standard excludes apparatus for
checking appliances using fuels other than gas,
continuous emission, safety monitoring and control, and
use in vessels with an international load line.
NOTE 1 When this apparatus is used in industrial premises, national regulations should be observed.
NOTE 2 Apparatus may contain functional modules which are not covered by this standard e.g. measurement of smoke spot number (see EN 267:2009+A1:2011, Annex A) and/or measurement of indoor ambient air (see EN 50543).
Standards | Relationship |
NBN EN 50379-3 : 2012 | Identical |
NF EN 50379-3 : 2012 | Identical |
NEN EN 50379-3 : 2012 | Identical |
I.S. EN 50379-3:2012 | Identical |
SN EN 50379-3 : 2012 | Identical |
DIN EN 50379-3 : 2013 | Identical |
UNE-EN 50379-3:2013 | Identical |
EN 50379-3:2012 | Identical |
BS 7967-4:2007 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances |
10/30213917 DC : 0 | BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES |
09/30205734 DC : 0 | BS 5864 - INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED HEAT INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION |
07/30150793 DC : 0 | BS 5440-1 - FUELING AND VENTILATION FOR GAS APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET (1ST, 2ND AND 3RD FAMILY GASES) - PART 1: SPECIFICATION FOR INSTALLATION OF GAS APPLIANCES TO CHIMNEYS AND FOR MAINTENANCE OF CHIMNEYS |
BS 6172(2010) : 2010 | SPECIFICATION FOR INSTALLATION, SERVICING AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES) |
BS 5546:2010 | Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net |
13/30261683 DC : 0 | BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET |
10/30204527 DC : 0 | BS 6172 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES) |
BS 7967-5:2010 | Carbon monoxide in dwellings and other premises and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in non-domestic premises for the measurement of carbon monoxide and carbon dioxide levels and the determination of combustion performance |
08/30166539 DC : DRAFT JULY 2008 | BS 6798 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS 7967:2015 | Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fired appliances |
BS 5871-2:2005 | Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases) |
BS 6798:2009 | Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net |
BS 5440-1:2008 | Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys |
BS 5871-3:2005 | Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Decorative fuel effect gas appliances of heat input not exceeding 20 kW (2nd and 3rd family gases) |
BS 6798:2014 | Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net |
BS 7967-1:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation |
BS 7967-3:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers |
08/30166742 DC : DRAFT JUNE 2008 | BS 7967-5 - MEASUREMENT OF CARBON MONOXIDE, CARBON DIOXIDE AND THE COMBUSTION PERFORMANCE OF GAS-FIRED EQUIPMENT - PART 5: GUIDE FOR USING ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS IN NON-DOMESTIC PREMISES FOR THE MEASUREMENT OF CARBON MONOXIDE AND CARBON DIOXIDE IN INDOOR AIR AND THE DETERMINATION OF COMBUSTION PERFORMANCE |
06/30112198 DC : DRAFT AUG 2006 | BS 7967-4 - CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF GAS-FIRED APPLIANCES - PART 4: GUIDE FOR USING ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS AS PART OF THE PROCESS OF SERVICING AND MAINTENANCE OF GAS-FIRED APPLIANCES |
BS 7967-2:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance |
09/30166542 DC : 0 | BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS 8660-1:2011 | Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances |
14/30258585 DC : 0 | BS 7967 - GUIDE FOR THE USE OF ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS FOR THE MEASUREMENT OF CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF DOMESTIC GAS FIRED APPLIANCES |
BS 5864:2010 | Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification |
EN 50270:2015 | Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
EN 60359:2002 | Electrical and electronic measurement equipment - Expression of performance |
(INVALID RECORD) EN 50543:2011/AC:2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.