BS EN 60939-1:2010
Current
The latest, up-to-date edition.
Passive filter units for electromagnetic interference suppression Generic specification
Hardcopy , PDF
English
30-11-2010
1 General
2 Terms, definitions and technical data
3 Test and measurement procedures
Annex A (informative) - Calculation of leakage current
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Specifies passive filter units for electromagnetic interference suppression for use within, or associated with, electronic or electrical equipment and machines.
Committee |
W/-
|
DevelopmentNote |
Supersedes 03/101947 DC & BS EN 133000. (11/2005) Supersedes BS EN 133100 and BS EN 133101. (07/2009) Supersedes 08/30193881 DC. (11/2010)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60939-1:2010 relates to passive filter units for electromagnetic interference suppression for use within, or associated with, electronic or electrical equipment and machines. Both single and multi-channel filters within one enclosure are included within the scope of this generic specification. This generic specification establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications within the IECQ-CECC system for electronic components. This edition includes the following significant technical changes with respect to the previous edition:
a) table 3 has been updated, specifying how to handle the Neutral by 3-phase filter with Neutral;
b) all details about \'Quality assessment\' have been deleted in this edition, because this standard is a safety standard;
c) filters shall be subjected to Test Aa of IEC 60068-2-1 for 16 h, using the degree of severity of the lower category temperature as prescribed in the relevant specification;
d) since IEC 60068-2-20 does no longer make a difference between Method 1A and 1B, but only describes Method 1, references to the method to be used are updated.
Standards | Relationship |
EN 60939-1:2010 | Identical |
IEC 60939-1:2010 | Identical |
NF EN 60939-1 : 2011 | Identical |
NBN EN 60939-1 : 2010 | Identical |
DIN EN 60939-1 : 2011 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IECQ 001002-3:2005 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ) - RULES OF PROCEDURE - PART 3: APPROVAL PROCEDURES |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
CISPR 17:2011 | Methods of measurement of the suppression characteristics of passive EMC filtering devices |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 55017 : 2011 | METHODS OF MEASUREMENT OF THE SUPPRESSION CHARACTERISTICS OF PASSIVE EMC FILTERING DEVICES (CISPR 17:2011) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.