CISPR 16-1-5:2014+AMD1:2016 CSV
Current
The latest, up-to-date edition.
Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
16-12-2016
CISPR 16-1-5:2014+A1:2016 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- site validation methods for other sites covered in CISPR 16-1-6 are added;
- smaller step sizes are specified for swept frequency measurements;
- the minimum ground plane size is increased;
- and other miscellaneous technical and editorial refinements are included. Keywords: electromagnetic compatibility
This consolidated version consists of the second edition (2014) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
The contents of the corrigendum 1 of August 2020 have been included in this copy.
Committee |
CISPR/CIS/A
|
DevelopmentNote |
Together with CISPR 16-1-1, CISPR 16-1-2, CISPR 16-1-3 and CISPR 16-1-4 supersedes CISPR 16-1. (11/2003) Also available in CD-ROM format. Stability Date: 2019. (12/2016)
|
DocumentType |
Standard
|
Pages |
385
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CEI EN 55016-1-5 : 2015 | Identical |
AS/NZS CISPR 16.1.5:2015 | Identical |
EN 55016-1-5:2015/A1:2017 | Identical |
NBN EN 55016 1-5 : 2015 | Identical |
IS 10052 : Part 1 : Sec 5 : 2018 | Identical |
OVE/ONORM EN 55016-1-5 : 2015 | Identical |
PN EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
VDE 0876-16-1-5 : 2015 | Identical |
NEN CISPR 16-1-5 : 2004 | Identical |
DIN EN 55016-1-5 : 2015 | Identical |
UNE-EN 55016-1-5:2008 | Identical |
NF EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
BS EN 55016-1-5:2015 | Identical |
NF EN 300433-1 : 2011 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - CITIZENS' BAND (CB) RADIO EQUIPMENT - PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT (V1.3.1) |
PD CISPR/TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Uncertainties in standardized EMC tests |
NF EN 301443 : 2006 | SATELLITE EARTH STATIONS AND SYSTEMS (SES) - HARMONIZED EN FOR VERY SMALL APERTURE TERMINAL (VSAT) - TRANSMIT-ONLY, TRANSMIT-AND-RECEIVE, RECEIVE-ONLY SATELLITE EARTH STATIONS OPERATING IN THE 4 GHZ AND 6 GHZ FREQUENCY BANDS COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE |
MIL-PRF-32236 Base Document:2007 | Generator, Chlorine - Portable Electrolytic (PECG) |
CEI EN 61000-4-21 : 2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS |
UNE-EN 55016-1-4:2011 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
TS 103 052 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RADIATED MEASUREMENT METHODS AND GENERAL ARRANGEMENTS FOR TEST SITES UP TO 100 GHZ |
NF EN 62310-2 : 2007 | STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
EN 62132-2:2011 | Integrated circuits - Measurement of electromagnetic immunity - Part 2: Measurement of radiated immunity - TEM cell and wideband TEM cell method |
EN 62310-2:2007 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
ETSI EN 300 440 V2.1.1:2017-03 | Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
I.S. EN 61967-4:2002 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 4: MEASUREMENT OF CONDUCTED EMISSIONS - 1 OHM/150 OHM DIRECT COUPLING METHOD |
CSA CISPR 16-1-1 : 2015 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
BS EN 62132-2:2011 | Integrated circuits. Measurement of electromagnetic immunity Measurement of radiated immunity. TEM cell and wideband TEM cell method |
BS EN 61967-4 : 2002 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 4: MEASUREMENT OF CONDUCTED EMISSIONS - 1 OHM/150 OHM DIRECT COUPLING METHOD |
DD IEC TS 61967-3 : DRAFT JAN 2006 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - MEASUREMENT OF RADIATED EMISSIONS - SURFACE SCAN METHOD |
07/30171843 DC : 0 | BS EN CISPR 16-1-1 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
EN 300 718-1 : 1.2.1 | AVALANCHE BEACONS OPERATING AT 457 KHZ; TRANSMITTER-RECEIVER SYSTEMS; PART 1: HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM |
I.S. EN 62310-2:2007 | STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
I.S. EN 61967-2:2005 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 2: MEASUREMENT OF RADIATED EMISSIONS - TEM CELL AND WIDEBAND TEM CELL METHOD |
UNE-EN 61000-4-21:2012 | Electromagnetic compatibility (EMC) -- Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
CEI EN 61967-4 : 2009 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 4: MEASUREMENT OF CONDUCTED EMISSIONS - 1 OHM/150 OHM DIRECT COUPLING METHOD |
NF EN 302264-1 : 2010 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - SHORT RANGE DEVICES - ROAD TRANSPORT AND TRAFFIC TELEMATICS (RTTT) - SHORT RANGE RADAR EQUIPMENT OPERATING IN THE 77 GHZ TO 81 GHZ BAND - PART 1: TECHNICAL REQUIREMENTS AND METHODS OF MEASUREMENT |
NF EN 302625 : 2010 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - 5 GHZ BROADBAND DISASTER RELIEF APPLICATIONS (BBDR) - HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
EN 303 204 : 2.1.2 | NETWORK BASED SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT TO BE USED IN THE 870 MHZ TO 876 MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 MW; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE DIRECTIVE 2014/53/EU |
I.S. EN 55016-1-4:2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS |
BS EN 55016-1-6 : 2015 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION |
BS EN 61967-2:2005 | Integrated circuits. Measurement of electromagnetic emissions, 150 kHz to 1 GHz Measurement of radiated emissions. TEM cell and wideband TEM cell method |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
BS EN 55016-1-4 : 2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
I.S. EN 55016-1-1:2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
CISPR 16-1-1:2015 RLV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
BS EN 55016-1-1 : 2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
EN 302 066 : 2.1.1 | SHORT RANGE DEVICES (SRD); GROUND- AND WALL-PROBING RADAR APPLICATIONS (GPR/WPR) IMAGING SYSTEMS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE DIRECTIVE 2014/53/EU |
EN 300 220-1 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT |
NF EN 302729-1 : 2011 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - SHORT RANGE DEVICES (SRD) - LEVEL PROBING RADAR (LPR) EQUIPMENT OPERATING IN THE FREQUENCY RANGES 6 GHZ TO 8,5 GHZ, 24,05 GHZ TO 26,5 GHZ, 57 GHZ TO 64 GHZ, 75 GHZ TO 85 GHZ - PART 1: TECHNICAL CHARACTERISTICS AND TEST METHODS (V1.1.2) |
I.S. EN 61000-4-21:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS |
NF EN 302571 : 2014 | INTELLIGENT TRANSPORT SYSTEMS (ITS) - RADIOCOMMUNICATIONS EQUIPMENT OPERATING IN THE 5855 MHZ TO 5925 MHZ FREQUENCY BAND - HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE (V1.2.1) |
BS EN 62310-2:2007 | Static transfer systems (STS) Electromagnetic compatibility (EMC) requirements |
BS EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Reverberation chamber test methods |
EN 305 550 : 2.1.0 DRAFT | SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT TO BE USED IN THE 40 GHZ TO 246 GHZ FREQUENCY RANGE; HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
NF EN 55016-1-4 : 2010 AMD 2 2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS |
CEI EN 62310-2 : 2007 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
IEC 62310-2:2006 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
IEC 61967-2:2005 | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 2: Measurement of radiated emissions - TEM cell and wideband TEM cell method |
IEC 61967-4:2002+AMD1:2006 CSV | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 4: Measurement of conducted emissions - 1 Ω/150 Ω direct coupling method |
IEC 62132-2:2010 | Integrated circuits - Measurement of electromagnetic immunity - Part 2: Measurement of radiated immunity - TEM cell and wideband TEM cell method |
10/30230478 DC : 0 | BS EN 55016-1-6 ED.1 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC-ANTENNA CALIBRATION |
CEI EN 62132-2 : 2012 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY PART 2: MEASUREMENT OF RADIATED IMMUNITY - TEM CELL AND WIDEBAND TEM CELL METHOD |
EN 303 131 : 1.1.0 DRAFT | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES; WIRELESS ALARMS WITH LOW DUTY CYCLE; HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE |
I.S. EN 62132-2:2011 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY - PART 2: MEASUREMENT OF RADIATED IMMUNITY - TEM CELL AND WIDEBAND TEM CELL METHOD |
I.S. EN 55016-1-6:2015 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION |
EN 61967-4 : 2002 COR 2017 | INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 4: MEASUREMENT OF CONDUCTED EMISSIONS - 1 OHM/150 OHM DIRECT COUPLING METHOD (IEC 61967-4:2002/COR1:2017) |
IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
EN 55016-1-6:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017) |
EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.