CLC/TS 61643-12:2009
Current
The latest, up-to-date edition.
LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
23-12-2009
0 Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 Systems and equipment to be protected
5 Surge protective devices
6 Application of SPDs in low-voltage power distribution systems
7 Risk analysis
8 Co-ordination where equipment has both signalling and power
terminals
Annex A (informative) Examples of various SPD technologies
Annex B (informative) Explanation of testing procedures used
in EN 61643-11
Annex C (informative) Partial lightning current calculations
Annex D (informative) Examples of application of CLC/TS 61643-12
Annex E (informative) Examples of application of the risk analysis
Annex F (informative) Consideration for SPDs when Type 1 SPDs
are to be applied
Annex G (informative) Immunity versus insulation withstand
Annex H (informative) Examples of SPD installation in power
distribution boards in some countries
Annex I (informative) Short circuit backup protection and
surge withstand
Annex J (informative) SPD coordination test principles
Annex K (informative) Simple calculation of I[imp] for a Type
1 SPD in case of a building protected by a LPS
Bibliography
IEC 61643-12:2008 describes the principles for selection, operation, location and coordination of SPDs to be connected to 50 Hz to 60 Hz a.c. and to d.c. power circuits and equipment rated up to 1 000 V r.m.s. or 1 500 V d.c. Specific change with respect to the previous edition is the incorporation of Amendment 1, which was not published separately due to the number of changes and pages.
Committee |
TC 37A
|
DevelopmentNote |
To be read in conjunction with EN 61643-11. (02/2010)
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI CLC/TS 61643-12 : 2010 | Identical |
PKN CLC/TS 61643-12 : 2007 | Identical |
S.R. CLC/TS 61643-12:2009 | Identical |
VDE V 0675-6-12 : 2010 | Identical |
IEC 61643-12:2008 | Identical |
DIN CLC/TS 61643-12 : 2010 | Identical |
NEN NPR IEC CLC/TS 61643-12 : 2010 | Identical |
I.S. CLC TS 61643-12:2006 | Identical |
UNE-CLC/TS 61643-12:2012 | Identical |
DD CLC/TS 61643-12:2009 | Identical |
UNE-EN 61400-24:2011 | Wind turbines - Part 24: Lightning protection |
S.R. HD 60364-5-534:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST TRANSIENT OVERVOLTAGES |
CEI CLC/TS 50544 : 2011 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
BS EN 62477-1 : 2012 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012) |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters |
HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
EN 61000-4-5:2014/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST (IEC 61000-4-5:2014/A1:2017) |
S.R. CLC/TS 50544:2010 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
CLC/TS 50539-22:2010 | Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 22: Selection and application principles - Wind turbine applications |
CEI EN 62305-4 : 2013 | PROTECTION CONTRE LA FOUDRE - PARTIE 4: RESEAUX DE PUISSANCE ET DE COMMUNICATION DANS LES STRUCTURES |
UNE 21186:2011 | Protection against lighting: Early streamer emission lightning protection systems. |
DD CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters |
BS EN 62305-4:2011 | Protection against lightning Electrical and electronic systems within structures |
I.S. EN 62305-4:2011 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES |
DD CLC/TS 61643-12:2009 | Low-voltage surge protective devices Surge protective devices connected to low-voltage power distribution systems. Selection and application principles |
UNE-EN 62305-4:2011 | Protection against lightning -- Part 4: Electrical and electronic systems within structures |
CEI EN 61400-24 : 2011 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
CLC/TS 50539-12:2013 | Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 12: Selection and application principles - SPDs connected to photovoltaic installations |
DD CLC/TS 50539-12:2010 | Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. SPDs connected to photovoltaic installations |
CEI CLC/TS 50539-12 : 2011 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 12: SELECTION AND APPLICATION PRINCIPLES - SPDS CONNECTED TO PHOTOVOLTAIC INSTALLATIONS |
I.S. HD 60364-5-534:2008 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST OVERVOLTAGES |
UNE-HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
PD CLC/TS 50539-12:2013 | Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. SPDs connected to photovoltaic installations |
DD CLC/TS 50539-22:2010 | Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. Wind turbine applications |
BS EN 61000-4-5:2014 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Surge immunity test |
S.R. CLC/TS 50539-12:2013 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 12: SELECTION AND APPLICATION PRINCIPLES - SPDS CONNECTED TO PHOTOVOLTAIC INSTALLATIONS |
S.R. CLC/TS 50539-22:2010 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 22: SELECTION AND APPLICATION PRINCIPLES - WIND TURBINE APPLICATIONS |
CEI CLC/TS 50539-22 : 2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 22: SELECTION AND APPLICATION PRINCIPLES - WIND TURBINE APPLICATIONS |
BS EN 61400-24:2010 | Wind turbines Lightning protection |
I.S. EN 61400-24:2010 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
EN 62477-1:2012/A1:2017 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012/A1:2016) |
UNE-CLC/TS 61643-12:2012 | Low-voltage surge protective devices -- Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
IEC 60038:2009 | IEC standard voltages |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 61643-12:2008 | Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
EN 61009-1:2012/A12:2016 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
IEC 61643-22:2015 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
EN 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences |
IEC 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
EN 62305-2:2012 | Protection against lightning - Part 2: Risk management |
IEC 61312-1:1995 | Protection against lightning electromagnetic impulse - Part 1: General principles |
IEC TR 62066:2002 | Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
EN 61008-1:2012/A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
CLC/TS 61643-22:2016 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.