EN 50104:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
01-07-2013
04-06-2010
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 Test methods
Annex A (informative) - Sequence of tests
Annex ZY (informative) - Significant changes between this
European Standard and EN 50104:2002
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
This European Standard specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). The apparatus, or parts thereof, may be intended for use in potentially explosive atmospheres (see 4.1) and in mines susceptible to firedamp. In the case of inert gas purging (inertization), it applies also to apparatus with an oxygen measuring function for explosion protection. NOTECommonly used oxygen sensors in commercial equipment for industrial application are: a) paramagnetic sensors; b) electrochemical sensors (aqueous and solid electrolytes); c) tunable diode laser absorption spectroscopy sensors (TDLAS). This standard is also applicable when an apparatus manufacturer makes any claims regarding any special features of construction or superior performance that exceed the minimum requirements of this standard. All such claims shall be verified and the test procedures shall be extended or supplemented, where necessary, to verify the claimed performance. The additional tests shall be agreed between the manufacturer and test laboratory and identified and described in the test report. This European Standard is applicable to oxygen alarm apparatus intended to measure reliably the oxygen concentration, to provide an indication, alarm or other output function, the purpose of which is to give a warning of a potential hazard and, in some cases, to initiate automatic or manual protective action(s), whenever the level exceeds or falls below a preselected alarm concentration. This standard is applicable to apparatus, including integral sampling systems of aspirated apparatus, intended to be used for commercial, industrial and non-residential safety applications. This standard does not apply to external sampling systems, or to apparatus of laboratory or scientific type, or to medical equipment, or to apparatus used only for process control purposes. For apparatus used for sensing the presence of multiple gases, this standard applies only to the measurement of oxygen. This standard is also applicable to apparatus using optical principles (e.g. TDLAS), where the optical transmitter and receiver or the optical transceiver (i.e. combined transmitter and receiver) and a suitable reflector are not located in a common enclosure. However, in this case it will be necessary to modify the test conditions described in Clause 5 and to introduce supplementary tests to Clause 6 of this standard. Such supplementary tests will include alignment, beam block fault, long range operation. Guidance to appropriate modification of the test conditions and supplementary tests may be taken from EN 60079 29 4. Modifications of the test conditions as well as modified and supplementary tests shall be agreed between the manufacturer and test laboratory and identified and described in the test report.
Committee |
CLC/TC 31
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
DS EN 50104 : 2010 | Identical |
OVE/ONORM EN 50104 : 2011 | Identical |
NBN EN 50104 : 2010 | Identical |
DIN EN 50104 : 2011 | Identical |
CEI EN 50104 : 2011 | Identical |
PN EN 50104 : 2011 | Identical |
UNE-EN 50104:2011 | Identical |
SN EN 50104 : 2010 | Identical |
I.S. EN 50104:2010 | Identical |
BS EN 50104:2010 | Identical |
NEN EN 50104 : 2010 | Identical |
VDE 0400-20 : 2011 | Identical |
NF EN 50104 : 2010 | Identical |
ONORM OVE EN 50104 : 1998 | Identical |
13/30260728 DC : 0 | BS EN 50402 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
BS EN 50270:2015 | Electromagnetic compatibility. Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
DIN EN 50402 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
08/30173506 DC : DRAFT JAN 2008 | BS EN 1539 - DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
I.S. EN 50402:2017 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
VDE 0400-70 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
EN 50073:1999 | Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen |
I.S. CEN/TR 15281:2006 | GUIDANCE ON INERTING FOR THE PREVENTION OF EXPLOSIONS |
UNI EN ISO 8230-3 : 2009 | SAFETY REQUIREMENTS FOR DRY-CLEANING MACHINES - PART 3: MACHINES USING COMBUSTIBLE SOLVENTS |
UNE-EN 50271:2011 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
BS EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen. Requirements on the functional safety of gas detection systems |
13/30260741 DC : 0 | BS EN 50270 - ELECTROMAGNETIC COMPATIBILITY - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN |
BS EN 16750:2017 | Fixed firefighting systems. Oxygen reduction systems. Design, installation, planning and maintenance |
EN 16750:2017 | Fixed firefighting systems - Oxygen reduction systems - Design, installation, planning and maintenance |
PREN 50402 : DRAFT 2013 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
I.S. EN 16750:2017 | FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE |
EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems |
PREN 1539 : DRAFT 2012 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
I.S. EN 1539:2015 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
DIN EN 1539:2016-02 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
VDE 0400-40-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
DIN EN 16750:2014-07 (Draft) | FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE |
12/30258755 DC : 0 | BS EN 1539 - DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
BS EN 50241-1:1999 | Specification for open path apparatus for the detection of combustible or toxic gases and vapours General requirements and test methods |
PD CEN/TR 15281:2006 | Guidance on inerting for the prevention of explosions |
DIN EN ISO 8230-3:2009-05 | SAFETY REQUIREMENTS FOR DRY-CLEANING MACHINES - PART 3: MACHINES USING COMBUSTIBLE SOLVENTS |
04/30115623 DC : DRAFT JUN 2004 | EN 50402 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
FD CEN/TR 15281 : 2006 FD | GUIDANCE ON INERTING FOR THE PREVENTION OF EXPLOSIONS |
BS EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen. Requirements and tests for apparatus using software and/or digital technologies |
NF EN 50271 : 2010 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
BS EN 1539:2015 | Dryers and ovens, in which flammable substances are released. Safety requirements |
EN 50241-1 : 99 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
I.S. EN 50270:2015 | ELECTROMAGNETIC COMPATIBILITY - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN |
DIN EN 50241-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
I.S. EN 50271:2010 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
ISO 8230-3:2008 | Safety requirements for dry-cleaning machines Part 3: Machines using combustible solvents |
IEC 62703:2013 | Expression of performance of fluorometric oxygen analyzers in liquid media |
UNE-EN 1539:2010 | Dryers and ovens, in which flammable substances are released - Safety requirements |
CEN/TR 15281:2006 | Guidance on Inerting for the Prevention of Explosions |
EN ISO 8230-3:2008 | Safety requirements for dry-cleaning machines - Part 3: Machines using combustible solvents (ISO 8230-3:2008) |
EN 1539:2015 | Dryers and ovens, in which flammable substances are released - Safety requirements |
BS EN ISO 8230-3:2008 | Safety requirements for dry-cleaning machines Machines using combustible solvents |
14/30297510 DC : 0 | BS EN 16750 - FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE |
BS EN 62703:2013 | Expression of performance of fluorometric oxygen analyzers in liquid media |
BS EN 50073:1999 | Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen |
CEI EN 50271 : 2011 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
I.S. EN 62703:2013 | EXPRESSION OF PERFORMANCE OF FLUOROMETRIC OXYGEN ANALYZERS IN LIQUID MEDIA (IEC 62703:2013 (EQV)) |
I.S. EN ISO 8230-3:2008 | SAFETY REQUIREMENTS FOR DRY-CLEANING MACHINES - PART 3: MACHINES USING COMBUSTIBLE SOLVENTS |
PREN 50270 : DRAFT 2013 | ELECTROMAGNETIC COMPATIBILITY - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN |
I.S. EN 50241-1:1999 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - GENERAL REQUIREMENTS AND TEST METHODS |
EN 62703:2013 | Expression of performance of fluorometric oxygen analyzers in liquid media |
EN 50270:2015 | Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
EN 50270:2015 | Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60079-29-4:2009 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.