EN 61709:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
22-03-2022
19-05-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Context and conditions
5 Generic reference conditions and stress models
6 Integrated semiconductor circuits
7 Discrete semiconductors
8 Optoelectronic components
9 Capacitors
10 Resistors and resistor networks
11 Inductors, transformers and coils
12 Microwave devices
13 Other passive components
14 Electrical connections
15 Connectors and sockets
16 Relays
17 Switches and push-buttons
18 Signal and pilot lamps
19 Printed circuit boards (PCB)
20 Hybrid circuits
Annex A (normative) - Failure modes of components
Annex B (informative) - Thermal model for semiconductors
Annex C (informative) - Failure rate prediction
Annex D (informative) - Considerations on mission profile
Annex E (informative) - Useful life models
Annex F (informative) - Physics of failure
Annex G (informative) - Considerations for the design of a
data base on failure rates
Annex H (informative) - Potential sources of failure rate
data and methods of selection
Annex I (informative) - Overview of component classification
Annex J (informative) - Presentation of component reliability data
Annex K (informative) - Examples
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
NEW!IEC 61709:2017 is available as IEC 61709:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61709:2017 gives guidance on the use of failure rate data for reliability prediction of electric components used in equipment. The method presented in this document uses the concept of reference conditions which are the typical values of stresses that are observed by components in the majority of applications. Reference conditions are useful since they provide a known standard basis from which failure rates can be modified to account for differences in environment from the environments taken as reference conditions. Each user can use the reference conditions defined in this document or use their own. When failure rates stated at reference conditions are used it allows realistic reliability predictions to be made in the early design phase. The stress models described herein are generic and can be used as a basis for conversion of failure rate data given at these reference conditions to actual operating conditions when needed and this simplifies the prediction approach. Conversion of failure rate data is only possible within the specified functional limits of the components. This document also gives guidance on how a database of component failure data can be constructed to provide failure rates that can be used with the included stress models. Reference conditions for failure rate data are specified, so that data from different sources can be compared on a uniform basis. If failure rate data are given in accordance with this document then additional information on the specified conditions can be dispensed with. This document does not provide base failure rates for components – rather it provides models that allow failure rates obtained by other means to be converted from one operating condition to another operating condition. The prediction methodology described in this document assumes that the parts are being used within its useful life. The methods in this document have a general application but are specifically applied to a selection of component types as defined in Clauses 6 to 20 and I.2. This third edition cancels and replaces the second edition, published in 2011. This edition constitutes a technical revision. This third edition is a merger of IEC 61709:2011 and IEC TR 62380:2004.
This edition includes the following significant technical changes with respect to the previous edition: addition of 4.5 Components choice, 4.6 Reliability growth during the deployment phase of new equipment, 4.7 How to use this document, and of Clause 19 Printed circuit boards (PCB) and Clause 20 Hybrid circuits with respect to IEC TR 62380; addition of failure modes of components in Annex A; modification of Annex B, Thermal model for semiconductors, adopted and revised from IEC TR 62380; modification of Annex D, Considerations on mission profile; modification of Annex E, Useful life models, adopted and revised from IEC TR 62380; revision of Annex F (former B.2.6.4), Physics of failure; addition of Annex G (former Annex C), Considerations for the design of a data base on failure rates, complemented with parts of IEC 60319; addition of Annex H, Potential sources of failure rate data and methods of selection; addition of Annex J, Presentation of component reliability data, based on IEC 60319.
Keywords: failure rate data, reliability prediction of electric components
Committee |
CLC/SR 56
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
Standards | Relationship |
IEC 61709:2017 | Identical |
OVE/ONORM EN 61709 : 2012 | Identical |
BS EN 61709:2017 | Identical |
UNE-EN 61709:2017 | Identical |
NBN EN 61709 : 2011 | Identical |
I.S. EN 61709:2017 | Identical |
SN EN 61709 : 2017 | Identical |
CEI EN 61709 : 2012 | Identical |
NF EN 61709 : 2017 | Identical |
PN EN 61709 : 2017 | Identical |
NEN EN IEC 61709 : 2017 | Identical |
UNE-EN 61709:2014 | Identical |
DIN EN 61709:2015-01 (Draft) | Identical |
PNE-FprEN 61709 | Identical |
BS EN 61069-5:2016 | Industrial-process measurement, control and automation. Evaluation of system properties for the purpose of system assessment Assessment of system dependability |
BS EN 61811-51:2002 | Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Non-standardized types and construction |
BS EN 61811-54:2002 | Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 15 mm x 7,5 mm base |
BS EN 62676-1-2:2014 | Video surveillance systems for use in security applications System requirements. Performance requirements for video transmission |
BS EN 50090-2-3:2005 | Home and building electronic systems (HBES) System overview. General functional safety requirements for products intended to be integrated in HBES |
I.S. EN 62506:2013 | METHODS FOR PRODUCT ACCELERATED TESTING (IEC 62506:2013 (EQV)) |
BS EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
CEI EN 50495 : 2011 | SAFETY DEVICES REQUIRED FOR THE SAFE FUNCTIONING OF EQUIPMENT WITH RESPECT TO EXPLOSION RISKS |
CEI EN 62308 : 2010 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
EN 61811-51:2002 | Electromechanical all-or-nothing relays - Part 51: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Non-standardized types and construction |
EN 61811-10:2003 | Electromechanical elementary relays of assessed quality - Part 10: Sectional specification - Relays for industrial application |
EN 62506 : 2013 | METHODS FOR PRODUCT ACCELERATED TESTING (IEC 62506:2013) |
EN 60300-3-15 : 2009 | DEPENDABILITY MANAGEMENT - PART 3-15: APPLICATION GUIDE - ENGINEERING OF SYSTEM DEPENDABILITY |
EN 60300-3-4:2008 | Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements |
EN 61811-54:2002 | Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base |
EN 62308 : 2006 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
I.S. EN 62676-1-2:2014 | VIDEO SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1-2: SYSTEM REQUIREMENTS - PERFORMANCE REQUIREMENTS FOR VIDEO TRANSMISSION |
BS EN 62506:2013 | Methods for product accelerated testing |
UNE-EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
I.S. EN 61811-53:2002 | ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 53: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 14 MM X 9 MM BASE |
I.S. EN 61811-54:2002 | ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 54: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 15 MM X 7,5 MM BASE |
BS EN 61811-50:2002 | Electromechanical all-or-nothing relays Sectional specification. Electromechanical all-or-nothing telecom relays of assessed quality |
BS EN 61811-10:2003 | Electromechanical all-or-nothing relays Sectional specification. Relays for industrial application |
BS EN 62308:2006 | Equipment reliability. Reliability assessment methods |
UNE-EN 62059-31-1:2010 | Electricity metering equipment - Dependability -- Part 31-1: Accelerated reliability testing - Elevated temperature and humidity |
I.S. EN 61811-52:2002 | ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 52: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 20 MM X 10 MM BASE |
EN 50126-1:2017 | Railway Applications - The Specification and Demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 1: Generic RAMS Process |
I.S. EN 61811-50:2002 | ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 50: SECTIONAL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY |
VDI 4007:2012-06 | Reliability goals - Determination, check, review, certificate |
VDI 3813 Blatt 1:2011-05 | Building automation and control systems (BACS) - Fundamentals for room control |
I.S. EN 61069-5:2016 | INDUSTRIAL-PROCESS MEASUREMENT, CONTROL AND AUTOMATION - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 5: ASSESSMENT OF SYSTEM DEPENDABILITY |
BS EN 61811-52:2002 | Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 20 mm x 10 mm base |
CEI EN 61069-5 : 1996 | INDUSTRIAL-PROCESS MEASUREMENT, CONTROL AND AUTOMATION - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 5: ASSESSMENT OF SYSTEM DEPENDABILITY |
BS EN 62059-31-1:2008 | Electricity metering equipment. Dependability Accelerated reliability testing. Elevated temperature and humidity |
BS EN 61811-53:2002 | Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 14 mm x 9 mm base |
BS EN 61811-55:2002 | Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 11 mm x 7,5 mm (max.) base |
BS EN 60300-3-15:2009 | Dependability management Application guide. Engineering of system dependability |
I.S. EN 50491-4-1:2012 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 4-1: GENERAL FUNCTIONAL SAFETY REQUIREMENTS FOR PRODUCTS INTENDED TO BE INTEGRATED IN BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) |
I.S. EN 50495:2010 | SAFETY DEVICES REQUIRED FOR THE SAFE FUNCTIONING OF EQUIPMENT WITH RESPECT TO EXPLOSION RISKS |
EN 62550:2017 | Spare parts provisioning |
CEI EN 62059-41 : 2007 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 41: RELIABILITY PREDICTION |
I.S. EN 50126-1:2017 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
BS EN 62059-41:2006 | Electricity metering equipment. Dependability Reliability prediction |
PREN 50126-1 : DRAFT 2015 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
BS EN 50491-4-1:2012 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) General functional safety requirements for products intended to be integrated in Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) |
CEI EN 62506 : 2014 | METHODS FOR PRODUCT ACCELERATED TESTING |
I.S. EN 50090-2-3:2005 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-3: SYSTEM OVERVIEW - GENERAL FUNCTIONAL SAFETY REQUIREMENTS FOR PRODUCTS INTENDED TO BE INTEGRATED IN HBES |
02/645215 DC : DRAFT OCT 2002 | EN 50090-2-3:2002 - HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-3: SYSTEM OVERVIEW - GENERAL FUNCTIONAL SAFETY REQUIREMENTS FOR PRODUCTS INTENDED TO BE INTEGRATED IN HBES |
BS EN 60300-3-1:2004 | Dependability management. Application guide Analysis techniques for dependability. Guide on methodology |
I.S. EN 62059-41:2006 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 41: RELIABILITY PREDICTION |
I.S. EN 62308:2006 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
IEC 61811-54:2002 | Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base |
EN 61811-52:2002 | Electromechanical all-or-nothing relays - Part 52: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 20 mm x 10 mm base |
I.S. EN 61811-10:2003 | ELECTROMECHANICAL ELEMENTARY RELAYS OF ASSESSED QUALITY - PART 10: SECTIONAL SPECIFICATION - RELAYS FOR INDUSTRIAL APPLICATION |
BS EN 62550:2017 | Spare parts provisioning |
I.S. EN 61811-51:2002 | ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 51: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - NON-STANDARDIZED TYPES AND CONSTRUCTION |
15/30330403 DC : 0 | BS EN 50126-1 - RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) - PART 1: GENERIC RAMS PROCESS |
BS EN 60300-3-4:2008 | Dependability management Application guide. Guide to the specification of dependability requirements |
CEI EN 50491-4-1 : 2014 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 4-1: GENERAL FUNCTIONAL SAFETY REQUIREMENTS FOR PRODUCTS INTENDED TO BE INTEGRATED IN BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) |
UNE-EN 50491-4-1:2013 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 4-1: General functional safety requirements for products intended to be integrated in Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) |
I.S. EN 60300-3-1:2004 | DEPENDABILITY MANAGEMENT - PART 3-1: APPLICATION GUIDE - ANALYSIS TECHNIQUES FOR DEPENDABILITY - GUIDE ON METHODOLOGY |
EN 61069-5:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 5: Assessment of system dependability |
EN 61811-55:2002 | Electromechanical all-or-nothing relays - Part 55: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 11 mm x 7,5 mm (max.) base |
EN 61811-53:2002 | Electromechanical all-or-nothing relays - Part 53: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 14 mm x 9 mm base |
EN 62676-1-2:2014/AC:2015 | VIDEO SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1-2: SYSTEM REQUIREMENTS - PERFORMANCE REQUIREMENTS FOR VIDEO TRANSMISSION (IEC 62676-1-2:2013) |
EN 60300-3-1:2004 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
EN 62059-31-1 : 2008 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 31-1: ACCELERATED RELIABILITY TESTING - ELEVATED TEMPERATURE AND HUMIDITY |
EN 62059-41:2006 | Electricity metering equipment - Dependability - Part 41: Reliability prediction |
EN 50491-4-1:2012 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 4-1: General functional safety requirements for products intended to be integrated in Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) |
EN 61811-50:2002 | Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality |
EN 50090-2-3:2005 | Home and Building Electronic Systems (HBES) - Part 2-3: System overview - General functional safety requirements for products intended to be integrated in HBES |
IEC 62308:2006 | Equipment reliability - Reliability assessment methods |
IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
EN 300 019-1-5 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-5: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; GROUND VEHICLE INSTALLATIONS |
IEC 60319:1999 | Presentation and specification of reliability data for electronic components |
IEC PAS 62435:2005 | Electronic components - Long-duration storage of electronic components - Guidance for implementation |
IEC 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
IEC 61649:2008 | Weibull analysis |
IEC 62741:2015 | Demonstration of dependability requirements - The dependability case |
IEC 61014:2003 | Programmes for reliability growth |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61360-4:2005 | Standard data element types with associated classification scheme for electric components - Part 4: IEC reference collection of standard data element types and component classes |
IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
ETS 300 200019-1-4 : 20001 | EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS |
VITA 51.2 : 2016 | PHYSICS OF FAILURE RELIABILITY PREDICTIONS |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
IEC 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations |
EN 300 019-1-7 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-7: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; PORTABLE AND NON-STATIONARY USE |
ISO 10303-31:1994 | Industrial automation systems and integration Product data representation and exchange Part 31: Conformance testing methodology and framework: General concepts |
IEC TR 62380:2004 | Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment |
IEC 61360-1:2017 | Standard data element types with associated classification scheme - Part 1: Definitions - Principles and methods |
IEC 60650:1979 | Analogue counting ratemeters. Characteristics and test methods |
ISO 10303-11:2004 | Industrial automation systems and integration Product data representation and exchange Part 11: Description methods: The EXPRESS language reference manual |
IEC 61810-2:2017 | Electromechanical elementary relays - Part 2: Reliability |
IEC 61163-2:1998 | Reliability stress screening - Part 2: Electronic components |
DEFSTAN 00-42(PT3)/4(2011) : 2011 | RELIABILITY AND MAINTAINABILITY ASSURANCE GUIDE - PART 3: R&M CASE |
IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 61810-2-1:2017 | Electromechanical elementary relays - Part 2-1: Reliability - Procedure for the verification of B<sub>10</sub> values |
IEC 60747-12-2:1995 | Semiconductor devices - Part 12: Optoelectronic devices - Section 2: Blank detail specification for laser diode modules with pigtail for fibre optic systems and sub-systems |
IEC 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEC 60747-1:2006+AMD1:2010 CSV | Semiconductor devices - Part 1: General |
MIL-C-18312 Revision G:2013 | CAPACITOR, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), GENERAL SPECIFICATION FOR |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 300 019-1-8 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-8: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; STATIONARY USE AT UNDERGROUND LOCATIONS |
IEC 60050-521:2002 | International Electrotechnical Vocabulary (IEV) - Part 521: Semiconductor devices and integrated circuits |
IEC 61710:2013 | Power law model - Goodness-of-fit tests and estimation methods |
ETS 300 200019-1-3 : 20001 | EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.