I.S. EN 60146-1-1:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
Hardcopy , PDF
09-05-2024
English
01-01-2010
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Operation of semiconductor power equipment and valve
devices
5 Service conditions
6 Power conversion equipment and assemblies
7 Tests for valve device assemblies and power conversion
equipment
Annex A (normative) Harmonics and interharmonics
Annex B (informative) Electrical environment -
Short-circuit ratio
Annex C (normative) Protection against electric shock and
energy hazards
Bibliography
Index of definitions
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Defines the requirements for the performance of all semiconductor power converters and semiconductor power switches using controllable and/or non-controllable electronic valve devices.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 60146-1-1:2009 | Identical |
BS EN 60146-1-1:2010 | Identical |
DIN EN 60146-1-1 : 2011 | Identical |
EN 60146-1-1:2010 | Identical |
SN EN 60146-1-1 : 1993 AMD 1 1997 | Identical |
UNE-EN 60146-1-1:1996 | Identical |
NF EN 60146-1-1 : 2011 | Identical |
IEC 61954:2011+AMD1:2013+AMD2:2017 CSV | Static var compensators (SVC) - Testing of thyristor valves |
IEC TR 61000-2-6:1995 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances |
IEEE 519-2014 REDLINE | IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
IEC 61287-1:2014 | Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods |
IEC TR 60146-6:1992 | Semiconductor convertors - Part 6: Application guide for the protection of semiconductor convertors against overcurrent by fuses |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC TS 61287-2:2001 | Power convertors installed on board railway rolling stock - Part 2: Additional technical information |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
IEC 62589:2010 | Railway applications - Fixed installations - Harmonisation of the rated values for converter groups and tests on converter groups |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 62310-2:2006 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
EN 61000-3-11:2000 | Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC PAS 61975:2004 | System tests for high-voltage direct current (HVDC) installations |
EN 61000-2-4:2002/AC:2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES |
IEC 62068-1:2003 | Electrical insulation systems - Electrical stresses produced by repetitive impulses - Part 1: General method of evaluation of electrical endurance |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
EN 61000-4-7:2002/A1:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008) |
IEC 62103:2003 | Electronic equipment for use in power installations |
EN 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
IEC 61204-3:2016 | Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
EN 61800-5-1:2007/A1:2017 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY (IEC 61800-5-1:2007/A1:2016) |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61954:2011/A2:2017 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011/A2:2017) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60700-1:2015 | Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing |
IEC TS 61000-6-5:2001 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments |
IEC 60076-1:2011 | Power transformers - Part 1: General |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 60146-2:1999 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC TS 61000-3-4:1998 | Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60747-1:2006+AMD1:2010 CSV | Semiconductor devices - Part 1: General |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN 61204-3:2000 | Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility (EMC) |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
IEC TR 60664-2-2:2002 | Insulation coordination for equipment within low-voltage systems - Part 2-2: Interface considerations - Application guide |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
EN 62040-2:2006/corrigendum:2006 | |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60700-1:2015/AC:2017-02 | THYRISTOR VALVES FOR HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - PART 1: ELECTRICAL TESTING (IEC 60700-1:2015/COR1:2017) |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC 62477-1:2012+AMD1:2016 CSV | Safety requirements for power electronic converter systems and equipment - Part 1: General |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC TR 61800-6:2003 | Adjustable speed electrical power drive systems - Part 6: Guide for determination of types of load duty and corresponding current ratings |
IEC 60050-521:2002 | International Electrotechnical Vocabulary (IEV) - Part 521: Semiconductor devices and integrated circuits |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61204-7:2016 EXV | LOW-VOLTAGE SWITCH MODE POWER SUPPLIES - PART 7: SAFETY REQUIREMENTS |
IEC 60050-551-20:2001 | International Electrotechnical Vocabulary (IEV) - Part 551-20: Power electronics - Harmonic analysis |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 62310-2:2007 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-