• There are no items in your cart

I.S. EN 60598-1:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS

Available format(s)

Hardcopy , PDF

Superseded date

12-04-2021

Superseded by

I.S. EN IEC 60598-1:2021

Language(s)

English

Published date

01-01-2015

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€218.00
Excluding VAT

National Foreword
FOREWORD
SECTION 0: GENERAL INTRODUCTION
SECTION 1: TERMS AND DEFINITIONS
SECTION 2: CLASSIFICATION OF LUMINAIRES
SECTION 3: MARKING
SECTION 4: CONSTRUCTION
SECTION 5: EXTERNAL AND INTERNAL WIRING
SECTION 7: PROVISION FOR EARTHING
SECTION 8: PROTECTION AGAINST ELECTRIC SHOCK
SECTION 9: RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE
SECTION 10: INSULATION RESISTANCE AND ELECTRIC STRENGTH,
            TOUCH CURRENT AND PROTECTIVE CONDUCTOR CURRENT
SECTION 11: CREEPAGE DISTANCES AND CLEARANCES
SECTION 12: ENDURANCE TEST AND THERMAL TEST
SECTION 13: RESISTANCE TO HEAT, FIRE AND TRACKING
SECTION 14: SCREW TERMINALS
SECTION 15: SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS
Annex A (normative) - Test to establish whether a
        conductive part may cause an electric shock
Annex B (normative) - Test lamps
Annex C (normative) - Abnormal circuit conditions
Annex D (normative) - Draught-proof enclosure
Annex E (normative) - Determination of winding temperature
        rises by the increase-in-resistance method
Annex F (normative) - Test for resistance to stress
        corrosion of copper and copper alloys
Annex G (normative) - Measurement of touch current and
        protective conductor current
Annex H (Void)
Annex I (Void)
Annex J (informative) - Explanation of IP numbers for
        degrees of protection
Annex K (informative) - Temperature measurement
Annex L (informative) - Guide to good practice in luminaire
        design
Annex M (normative) - Determination of creepage distances
        and clearances
Annex N (informative) - Explanation of marking for
        luminaires that are not suitable for mounting on
        normally flammable surfaces and covering with
        insulation materials
Annex O (Void)
Annex P (normative) - Absorption requirements for the
        protective shield to be fitted to luminaires
        designed for metal halide lamps which emit a high
        level of UV radiation
Annex Q (informative) - Conformity testing during
        manufacture
Annex R (normative) - Schedule of amended clauses and
        subclauses containing more serious/critical
        requirements which call for products to be retested
Annex S (normative) - Requirements for the identification
        of a family or range of luminaires for type testing
Annex T (Void)
Annex U (informative) - Creepage and clearances distances
        for luminaires with a higher degree of availability
        (impulse withstand category III)
Annex V (normative) - Additional test requirements for
        terminal blocks with integrated screwless earthing
        contact for direct connection to the luminaire
        housing or to parts of the body
Annex W (normative) - Alternative thermal test for
        thermoplastic luminaires
Annex X (normative)
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Annex ZZ (informative) - Relationship between this European
         standard and the safety objectives of Directive
         2014/35/EU [2014 OJ L96] aimed to be covered
Annex ZB (normative) - Special national conditions
Annex ZC (informative) - A-deviations

Defines general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1000 V.

DevelopmentNote
NSAI reissued 2015 PDF dated 11.05.2017 with IEC Corrigenda incorporated. (05/2017) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (03/2018)
DocumentType
Standard
Pages
510
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

I.S. 3217:2013 EMERGENCY LIGHTING

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
EN 60634:1995 Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires
IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60238:2016+AMD1:2017 CSV Edison screw lampholders
IEC 60061-3:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
IEC 60228:2004 Conductors of insulated cables
EN 62031:2008/A2:2015 LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS (IEC 62031:2008/A2:2014)
IEC TR 62778:2014 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires
IEC 60664-4:2005 Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
EN 60998-2-2:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60662:2011 High-pressure sodium vapour lamps - Performance specifications
EN 60238 : 2004 AMD 2 2011 EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011)
IEC 60682:1980 Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps
EN 61347-2-9:2013 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
IEC 60634:1993 Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
EN 61558-1:2005/A1:2009 SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS
IEC 61347-2-9:2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
IEC TR 60083:2015 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
EN 61199:2011/A2:2015 SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61199:2011/A2:2014)
EN 60432-2:2000/A2:2012 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES
EN 60400:2017 Lampholders for tubular fluorescent lamps and starterholders
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 60998-2-1:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
IEC 60061-2:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60570:2003+AMD1:2017 CSV Electrical supply track systems for luminaires
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
IEC 60598-2-5:2015 Luminaires - Part 2-5: Particular requirements - Floodlights
IEC 60400:2017 Lampholders for tubular fluorescent lamps and starterholders
EN 61558-2-5:2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Particular requirements and tests for transformer for shavers, power supply units for shavers and shaver supply units
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 60598-2-6:1994 Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps
ISO 75-2:2013 Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
IEC 61167:2015 Metal halide lamps - Performance specification
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
IEC 61346-1:1996 Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules
EN 60357:2003/A11:2016 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS
IEC 60364-7-702:2010 Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
IEC 60921:2004+AMD1:2006 CSV Ballasts for tubular fluorescent lamps - Performance requirements
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
IEC 60364-7-701:2006 Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
EN 60360:1998 Standard method of measurement of lamp cap temperature rise
IEC 62035:2014+AMD1:2016 CSV Discharge lamps (excluding fluorescent lamps) - Safety specifications
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61058-1:2016 Switches for appliances - Part 1: General requirements
EN 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
EN 62035:2014 Discharge lamps (excluding fluorescent lamps) - Safety specifications
IEC 60989:1991 Separating transformers, autotransformers, variable transformersand reactors.
EN 61032:1998 Protection of persons and equipment by enclosures - Probes for verification
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
IEC 80416-1:2008 Basic principles for graphical symbols for use on equipment - Part 1: Creation of graphical symbols for registration
IEC 62471:2006 Photobiological safety of lamps and lamp systems
HD 193 : 200S2 VOLTAGE BANDS FOR ELECTRICAL INSTALLATIONS OF BUILDINGS
EN 60155:1995/A2:2007 GLOW-STARTERS FOR FLUORESCENT LAMPS
IEC 61535:2009+AMD1:2012 CSV Installation couplers intended for permanent connection in fixedinstallations
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 61058-1:2002/A2:2008 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
EN 61184:2017 Bayonet lampholders
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 61558-2-5:2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units
IEC 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes
EN 60664-4:2006/corrigendum:2006 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS
EN 60662:2012 High-pressure sodium vapour lamps - Performance specifications
ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60432-3:2013 Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle)
AS 3771-1998 Road lighting luminaires with integral control gear
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 80416-1:2009 Basic principles for graphical symbols for use on equipment - Part 1: Creation of graphical symbols for registration
IEC 60155:1993 Glow-starters for fluorescent lamps
EN 60432-1:2000/A2:2012 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 1 - TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES (IEC 60432-1:1999/A2:2011)
EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
IEC 60923:2005+AMD1:2006 CSV Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements
IEC 60432-3:2012 Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle)
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
EN 62471:2008 Photobiological safety of lamps and lamp systems
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60998-2-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
IEC 60598-2-4:2017 Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires
IEC 61184:2017 Bayonet lampholders
IEC 60990:2016 Methods of measurement of touch current and protective conductor current
ISO 16893-1:2008 Wood-based panels Particleboard Part 1: Classifications
IEC 60360:1998 Standard method of measurement of lamp cap temperature rise
EN 60682:1993/A2:1997 METHOD OF MEASURING THE PINCH TEMPERATURE OF QUARTZ GLASS LAMPS
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications
EN 60990:2016 Methods of measurement of touch current and protective conductor current
ISO 1891:2009 Fasteners — Terminology

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.