FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
  3.1 General definitions
  3.2 Definitions related to the functional
      elements
  3.3 Definitions of mechanical elements
  3.4 Definitions of insulations
  3.5 Definitions of meter quantities
  3.6 Definitions of influence quantities
  3.7 Definition of tests
4 Requirements
  4.1 Standard electrical values
  4.2 Mechanical requirements
  4.3 Climatic Conditions
  4.4 Electrical requirements
  4.5 Electromagnetic compatibility (EMC)
  4.6 Accuracy requirements
5 Tests and test conditions
  5.1 General testing procedures
  5.2 Tests of mechanical requirements
  5.3 Tests of climatic influences
  5.4 Tests of electrical requirements
  5.5 Tests for electromagnetic compatibility (EMC)
  5.6 Tests of accuracy requirements
Tables
1 Standard reference voltages
2 Standard reference currents
3a Clearances and creepage distances for insulating
   encased meter of protective class I
3b Clearances and creepage distances for insulating
   encased meter of protective class II
4 Voltage marking
5 Temperature range
6 Relative humidity
7 Power consumption in voltage circuits including
   the power supply
8 Power consumption in voltage circuits including
   power supply
9 Voltage range
10 Variations due to short-time overcurrents
11 Variations due to self-heating
12 Change of error due to earth fault
13 Percentage error (single-phase meters and
   polyphase meters with balanced loads)
14 Percentage error limits (polyphase meters carrying
   a single-phase load, but with balanced polyphase
   voltages applied to voltage circuits)
15 Influence quantities
16 Temperature coefficient
17 Starting current
18 AC voltage tests
19 Voltage and current balance
20 Reference conditions
21 Interpretation of test results
Annexes
A Relationship between ambient air temperature
  and relative humidity
B Test circuit diagram for d.c., even harmonics,
  odd harmonics and sub-harmonics
C Voltage waveform for the tests of the effect of
  voltage dips and short interruptions
D Electromagnet for testing the influence of externally
  produced magnetic fields
E Test schedule
F Test circuit diagram for the test of immunity
  to earth fault

Applies only to newly manufactured indoor or outdoor static watt-hour meters of accuracy classes 1 and 2, for the measurement of alternating-current electrical active energy of a frequency in the range 45 Hz to 65 Hz and to their type tests only.

DocumentType
Standard
Pages
143
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

IEC 60038:2009 IEC standard voltages
EN 60687:1992/corrigendum:1993 ALTERNATING CURRENT STATIC WATT HOUR METERS FOR ACTIVE ENERGY (CLASSES 0.2S AND 0.5S)
EN 62053-31:1998 Electricity metering equipment (a.c.) - Particular requirements - Part 31: Pulse output devices for electromechanical and electronic meters (two wires only)
HD 323.2.5 : 200S1 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST SA - SIMULATED SOLAR RADIATION AT GROUND LEVEL
IEC 60068-2-5:2010 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
HD 323.2.11 : 200S1 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST KA: SALT MIST
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60695-2-1:1991 Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance
EN 60387:1992 Symbols for alternating-current electricity meters
IEC 60521:1988 Class 0.5, 1 and 2 alternating-current watthour meters
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC TR 60736:1982 Testing equipment for electrical energy meters
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60521:1995/corrigendum Dec. 1997 CLASS 0,5, 1 AND 2 ALTERNATING-CURRENT WATTHOUR METERS
EN 60514:1995 Acceptance inspection of Class 2 alternating-current watthour meters
IEC 60687:1992 Alternating current static watt-hour meters for active energy (classes 0,2 S and 0,5 S)
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
ISO 75-2:2013 Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
IEC 62053-31:1998 Electricity metering equipment (a.c.) - Particular requirements - Part 31: Pulse output devices for electromechanical and electronic meters (two wires only)
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
HD 323.2.30 : 200S3 BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2: TESTS - TEST DB AND GUIDANCE: DAMP HEAT, CYCLIC (12 + 12-HOUR CYCLE)
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
HD 554 : 200S1 VOLTAGE TRANSFORMERS
HD 566 : 200S1 THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 1: Current transformers
HD 323.2.6 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST FC AND GUIDANCE: VIBRATION (SINUSOIDAL)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60417C:1977 Third supplement.
IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 60044-1:1999/A2:2003 INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
IEC 60186:1987 Voltage transformers
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60387:1992 Symbols for alternating-current electricity meters
HD 243 : S12 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.