IEC 62128-1:2013
Current
The latest, up-to-date edition.
Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 1: Protective provisions against electric shock
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
16-09-2013
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Contact line zone and current collector zone
5 Protective provisions against direct contact
6 Protective provisions against indirect contact
7 Protective provisions for low voltage non-traction
power supplies
8 Protective provisions where track systems, which
are utilized for carrying traction return current,
or/and contact line systems pass through hazardous
zones
9 Limits for touch voltage and protective provisions
against the danger of rail potential
10 Additional protective provisions
Annex A (informative) - Typical obstacles
Annex B (normative) - Warning sign
Annex C (informative) - Guiding values for rail potential
gradient
Annex D (informative) - Effective touch voltage and body
voltage with respect to the body current
Annex E (normative) - Measurement methods for effective
touch voltages
Annex F (normative) - The use of voltage-limiting devices
Annex G (normative) - Special national conditions
Annex H (normative) - A-deviations
Annex I (informative) - Principles for the return circuit
of a.c. railways
Bibliography
IEC 62128-1:2013 specifies requirements for the protective provisions relating to electrical safety in fixed installations associated with a.c. and/or d.c. traction systems and to any installations that can be endangered by the traction power supply system. It also applies to all aspects of fixed installations that are necessary to ensure electrical safety during maintenance work within electric traction systems. This standard applies to all new lines and to all major revisions to existing lines. The main technical changes with regard to the previous edition are the restructuring of all clauses and changes in the touch voltages limits.
DevelopmentNote |
Stability date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
183
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN IEC 62128-1 : 2003 | Identical |
IEEE 1653.3-2012 | IEEE Guide for Rail Transit Traction Power Systems Modeling |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 62128-3:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 3: Mutual interaction of a.c. and d.c. traction systems |
11/30215604 DC : 0 | BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 62128-2:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 2: Provisions against the effects of stray currents caused by d.c. traction systems |
12/30247714 DC | BS IEC 62128-2. Railway applications. Fixed installations. Electrical safety, earthing and the return circuit. Part 2. Provisions against the effects of stray currents caused by d.c. traction systems |
BS EN 62267:2009 | Railway applications. Automated urban guided transport (AUGT). Safety requirements |
PD IEC TS 62993:2017 | Guidance for determination of clearances, creepage distances and requirements for solid insulation for equipment with a rated voltage above 1 000 V AC and 1 500 V DC, and up to 2 000 V AC and 3 000 V DC |
UNE-EN 62267:2011 | Railway applications - Automated urban guided transport (AUGT) - Safety requirements |
IEC 61992-1:2006+AMD1:2014 CSV | Railway applications - Fixed installations - DC switchgear - Part 1:General |
IEC 61992-7-1:2006 | Railway applications - Fixed installations - DC switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide |
CEI EN 62267 : 2011 | RAILWAY APPLICATIONS - AUTOMATED URBAN GUIDED TRANSPORT (AUGT) - SAFETY REQUIREMENTS |
I.S. EN 62267:2009 | RAILWAY APPLICATIONS - AUTOMATED URBAN GUIDED TRANSPORT (AUGT) - SAFETY REQUIREMENTS |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
IEC 62267:2009 | Railway applications - Automated urban guided transport (AUGT) - Safety requirements |
12/30247717 DC : 0 | IEC 62128-3 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 3: MUTUAL INTERACTION OF AC AND DC TRACTION SYSTEMS |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
IEC 62848-1:2016 | Railway applications - DC surge arresters and voltage limiting devices - Part 1: Metal-oxide surge arresters without gaps |
IEC 62505-1:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
EN 62267:2009 | Railway applications - Automated urban guided transport (AUGT) - Safety requirements |
IEC 61219:1993 | Live working - Earthing or earthing and short-circuiting equipment using lances as a short-circuiting device - Lance earthing |
ISO 7010:2011 | Graphical symbols Safety colours and safety signs Registered safety signs |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
EN 61219:1993 | Live working - Earthing or earthing and short-circuiting equipment using lances as short-circuiting device - Lance earthing |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 50122-3:2010 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 3: Mutual Interaction of a.c. and d.c. traction systems |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62128-2:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 2: Provisions against the effects of stray currents caused by d.c. traction systems |
IEC 61991:2000 | Railway applications - Rolling stock - Protective provisions against electrical hazards |
IEC 60050-821:1998 | International Electrotechnical Vocabulary (IEV) - Part 821: Signalling and security apparatus for railways |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 50388 : 2012 COR 2013 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
IEC 60050-111:1996 | International Electrotechnical Vocabulary (IEV) - Part 111: Physics and chemistry |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62724:2013 | Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines |