ISA 12.13.01 : 2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS
Hardcopy , PDF
07-08-2013
English
01-01-2003
Foreword
Introduction
1 General
2 Definitions
3 General requirements
4 Test methods
5 Field calibration kit
Annex A (normative) - Flammability limits (i.e. LFL and UFL)
of some flammable gases and vapours
Annex B (informative) - Determination of time of response
Annex C (informative) - Bibliography
Annex D (informative) - National deviations
Part 2 (IEC 61779-2 Mod) - Electrical apparatus for the detection and
measurement of flammable gases - Part 2: Performance requirements
for group I apparatus indicating a volume fraction up to 100% lower
explosive limit
Annex A (informative) - National deviations
Part 3 (IEC 61779-3 Mod) - Electrical apparatus for the detection and
measurement of flammable gases - Part 3: Performance requirements
for group I apparatus indicating a volume fraction up to 100% methane
in air
Annex A (informative) - National deviations
Part 4 (IEC 61779-4 Mod) - Electrical apparatus for the detection and
measurement of flammable gases - Part 4: Performance requirements
for group II apparatus indicating a volume fraction up to 100% lower
explosive limit
1 Scope
2 Definitions
3 General requirements
4 Performance requirements
5 Field calibration kit
Annex A (informative) - National deviations
Part 5 (IEC 61779-5 Mod) - Electrical apparatus for the detection and
measurement of flammable gases - Part 5: Performance requirements
for group II apparatus indicating a volume fraction up to 100% gas
1 Scope
2 Definitions
3 General requirements
4 Performance requirements
5 Field calibration kit
Annex A (informative) - National deviations
Defines general requirements for construction and testing and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of flammable gas or vapour concentrations with air.
Committee |
SP12
|
DevelopmentNote |
Supersedes ISA 12.13-1. (05/2001) Renumbered as ISA 60079-29-1. (07/2013)
|
DocumentType |
Standard
|
Pages |
108
|
PublisherName |
International Society of Automation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 61779-2:1998 | Identical |
IEC 61779-4:1998 | Identical |
IEC 61779-3:1998 | Identical |
IEC 61779-5:1998 | Identical |
ANSI FC 1 : 2012 | STATIONARY FUEL CELL POWER SYSTEMS |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
ISA TR12.13.03 : 2009 | GUIDE FOR COMBUSTIBLE GAS DETECTION AS A METHOD OF PROTECTION |
ANSI/ISA-92.00.02:2013 | INSTALLATION, OPERATION, AND MAINTENANCE OF TOXIC GAS-DETECTION INSTRUMENTS |
ISA 92.00.01 : 2010(R2015) | PERFORMANCE REQUIREMENTS FOR TOXIC GAS DETECTORS |
API 500 RUSSIAN : 1997 : R2002 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
API 500 RUSSIAN :1997 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
ISA RP92.04.02-2 : 1996 | INSTALLATION, OPERATION, AND MAINTENANCE OF INSTRUMENTS USED TO DETECT OXYGEN-DEFICIENT/OXYGEN-ENRICHED ATMOSPHERES |
ISA 92.04.01-1 : 2007 | PERFORMANCE REQUIREMENTS FOR INSTRUMENTS USED TO DETECT OXYGEN-DEFICIENT/OXYGEN-ENRICHED ATMOSPHERES |
04/30112677 DC : 0 | IEC 61779-1 ED.2 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
ANSI/CSA FC 1:2014 | FUEL CELL TECHNOLOGIES - PART 3-100: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
API 505 : 1997 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2 |
API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
ISA RP92.06.02 : 1999 | INSTALLATION, OPERATION, AND MAINTENANCE OF CHLORINE DETECTION INSTRUMENTS (0.5-30 PPM FULL SCALE) |
ISA RP92.03.02 : 1999 | INSTALLATION, OPERATION, AND MAINTENANCE OF AMMONIA DETECTION INSTRUMENTS (25-500 PPM - FULL SCALE) |
ISA RP92.02.02-2 : 1998 | INSTALLATION, OPERATION, AND MAINTENANCE OF CARBON MONOXIDE DETECTION INSTRUMENTS (50-1000 PPM FULL SCALE) |
ISA RP92.0.02-2 : 1998 | INSTALLATION, OPERATION, AND MAINTENANCE OF TOXIC GAS-DETECTION INSTRUMENTS: HYDROGEN SULFIDE |
ISA 12.16.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
EN 50058:1998 | Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % (v/v) gas |
ISO 2738:1999 | Sintered metal materials, excluding hardmetals — Permeable sintered metal materials — Determination of density, oil content and open porosity |
ISA 12.26.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O" |
EN 50039:1980 | Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i' |
ISA 12.25.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - POWDER FILLING "Q" |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
ISA 12.12.01 : 2007 | NONINCENDIVE ELECTRICAL EQUIPMENT FOR USE IN CLASS 1 AND 2, DIVISION 2 AND CLASS 3, DIVISIONS 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS |
ISA TR12.24.01 : 1998 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS CLASSIFIED AS CLASS 1, ZONE 0, ZONE 1, OR ZONE 2 |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
ISO 4003:1977 | Permeable sintered metal materials — Determination of bubble test pore size |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 50055:1998 | Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 5 % (v/v) methane in air |
ISA 12.02.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONES 0, 1 & 2 HAZARDOUS (CLASSIFIED) LOCATIONS - INTRINSIC SAFETY |
EN 50017:1998 | Electrical apparatus for potentially explosive atmospheres - Powder filling "q" |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
EN 50057:1998 | Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % lower explosive limit |
ISO 6147:1979 | Gas analysis Preparation of calibration gas mixtures Saturation method |
ISA 12.00.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO 4022:1987 | Permeable sintered metal materials — Determination of fluid permeability |
ISA 12.23.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - ENCAPSULATION "M" |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
EN 50015:1998 | Electrical apparatus for potentially explosive atmospheres - Oil immersion "o" |
EN 50056:1998 | Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 100 % (v/v) methane in air |
BS 5345-1:1989 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) General recommendations |
EN 50016:2002 | Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p" |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
EN 50028:1987 | Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm' |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
FM 6310,20 : 2001 | COMBUSTIBLE GAS DETECTORS |
IEC 61779-1:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 1: General requirements and test methods |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
ISA 12.22.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS TYPE OF PROTECTION - FLAMEPROOF "D" |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.