BS 5839-1:2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises

Available format(s)

Hardcopy , PDF

Superseded date

31-08-2017

Superseded by

BS 5839-1:2017

Language(s)

English

Published date

31-03-2013

€416.02
Excluding VAT

Foreword
Section 1: General
1 Scope
2 Normative references
3 Terms and definitions
4 Need for a fire detection and fire alarm
   system and type of system
5 Categories of system
6 Exchange of information and definition of
   responsibilities
7 Variations from the recommendations of
   this standard
Section 2: Design considerations
8 Relationship between system Category and
   areas protected
9 Actuation of other fire protection systems or
   safety facilities
10 Systems in explosive gas or dust atmospheres
11 System components
12 Monitoring, integrity and reliability of circuits
   external to control equipment
13 Detection zones
14 Alarm zones
15 Communication with the fire and rescue service
16 Audible alarm signals
17 Visual alarm signals
18 Fire alarm warnings for people with impaired hearing
19 Staged fire alarms
20 Manual call points
21 Types of fire detector and their selection
22 Spacing and siting of automatic fire detectors
23 Control and indicating equipment
24 Networked systems
25 Power supplies
26 Cables, wiring and other interconnections
27 Radio-linked systems
28 Electromagnetic compatibility
29 Electrical safety
Section 3: Limitation of false alarms
30 Responsibility for limitation of false alarms
31 Categories of false alarms
32 Acceptable rate of false alarms
33 Causes of false alarms
34 Design process for limitation of false alarms
35 Measures to limit false alarms
Section 4: Installation
36 Responsibility of installer
37 Installation practices and workmanship
38 Inspection and testing of wiring
Section 5: Commissioning and handover
39 Commissioning
40 Documentation
41 Certification
42 Acceptance
43 Verification
Section 6: Maintenance
44 Routine testing
45 Inspection and servicing
46 Non-routine attention
Section 7: User's responsibilities
47 Premises management
48 Logbook
Annexes
Annex A (informative) - Choice of appropriate
        category of fire detection and fire
        alarm system
Annex B (informative) - Typical noise levels in
        buildings
Annex C (normative) - Control and transmission
        equipment for tactile alarm devices provided
        for people with impaired hearing systems
Annex D (normative) - Method for calculating
        standby battery capacity
Annex E (informative) - Schematic for design against
        false alarms
Annex F (informative) - Visual alarm device illumination
        characteristics
Annex G (informative) - Model format for system logbook
Annex H (informative) - Model certificates
Bibliography

Gives recommendations for the planning, design, installation, commissioning and maintenance of fire detection and fire alarm systems in and around buildings, other than domestic premises.

Committee
FSH/12/1
DevelopmentNote
Supersedes BS 5839-1(2002) & 12/30260278 DC. (04/2013)
DocumentType
Standard
Pages
324
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of BS 5839 provides recommendations for the planning, design, installation, commissioning and maintenance of fire detection and fire alarm systems in and around buildings, other than domestic premises. It does not recommend whether or not a fire detection and fire alarm system should be installed in any given premises. Recommendations for fire detection and fire alarm systems in domestic premises are given in BS 5839-6.

The term fire detection and fire alarm systems, in the context of this part of BS 5839, includes systems that range from those comprising only one or two manual call points and sounders to complex networked systems that incorporate a large number of automatic fire detectors, manual call points and sounders, connected to numerous inter-communicating control and indicating panels.

The term also includes systems that are capable of providing signals to initiate the operation of other fire protection systems and equipment (such as fire extinguishing systems, smoke control systems or automatic door release equipment) or safety measures (such as shutdown of air handling systems, closing of oil or gas valves or grounding of lifts). It does not apply to the other systems and equipment themselves, or the ancillary circuits to interface with them. Recommendations for the planning, installation and servicing of facilities for operation of certain fire protection systems by the systems addressed within this part of BS 5839 are given in BS 7273.

This part of BS 5839 does not cover systems whose primary function is to extinguish or control fire, such as sprinkler or automatic extinguishing systems, even though they might have a secondary alarm function; it does, however, cover the use of a signal from an automatic extinguishing system as one initiating element of a fire alarm system (e.g. by use of a pressure or flow switch).

This part of BS 5839 does not cover voice alarm systems. Recommendations for voice alarm systems and voice enhanced sounders are given in BS 5839-8.

This part of BS 5839 does not cover systems combining fire alarm functions with other non-fire related functions. Recommendations for such integrated systems are given in DD CLC/TS 50398.

This part of BS 5839 does not cover the 999 (or 112) public emergency call system, or manually or mechanically operated sounders.

This part of BS 5839 does not cover audible or visual way-guidance systems which are designed to complement fire alarm systems.

Recommendations for fire detection and fire alarm systems in electronic data processing installations and similar critical electronic equipment rooms are given in BS 6266, which provides recommendations over and above those given in this part of BS 5839.

Recommendations for fire detection and fire alarm systems in hospitals are given in the NHS Estates publications HTM 05-03 Part B (in England and Wales) or SHTM 82 (in Scotland).

This part of BS 5839 applies to extensions and alterations to existing systems, at least in respect of the design, installation, commissioning and certification of the new work, albeit that the extended or altered system might not, overall, conform to the recommendations of this standard.

14/30295204 DC : 0 BS 7629-1 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V FIRE RESISTANT SCREENED CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE FOR FIXED INSTALLATIONS - PART 1: MULTICORE CABLES
BS 9999:2017 Fire safety in the design, management and use of buildings. Code of practice
I.S. 3218:2013 FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - SYSTEM DESIGN, INSTALLATION, COMMISSIONING, SERVICING AND MAINTENANCE
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 9251:2014 Fire sprinkler systems for domestic and residential occupancies. Code of practice
BS 7629-1:2015+A1:2019 Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables
BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 8591:2014 Remote centres receiving signals from alarm systems. Code of practice
13/30286749 DC : 0 BS 8591 - REMOTE CENTRES RECEIVING SIGNALS FROM ALARM SYSTEMS - CODE OF PRACTICE
BS 5839-8:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS 8492(2016) : 2016 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
17/30335834 DC : 0 BS 8300-2 - DESIGN OF AN ACCESSIBLE AND INCLUSIVE BUILT ENVIRONMENT - PART 2: BUILDINGS - CODE OF PRACTICE
BS 7346-8:2013 Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance
16/30336629 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE
15/30288999 DC : 0 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
14/30280481 DC : 0 BS 9251 - FIRE SPRINKLER SYSTEMS FOR DOMESTIC AND RESIDENTIAL OCCUPANCIES - CODE OF PRACTICE
14/30295814 DC : 0 BS 8489-1 - FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
13/30275054 DC : 0 BS 7499 - STATIC SITE GUARDING AND MOBILE PATROL SERVICES - CODE OF PRACTICE
13/30266935 DC : 0 BS 7346-8 - COMPONENTS FOR SMOKE CONTROL SYSTEMS - PART 8: CODE OF PRACTICE FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 7346-7:2013 Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks
BS 8489-1:2016 Fixed fire protection systems. Industrial and commercial watermist systems Code of practice for design and installation
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 7629-1:2015 Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables
BS 7499:2013 Static site guarding and mobile patrol service. Code of practice

BS EN 54-23:2010 Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices
BS 4678-4:1982 Cable trunking Specification for cable trunking made of insulating material
DD CLC/TS 50398:2009 Alarm systems. Combined and integrated systems. General requirements
IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
BS ISO 7240-15:2014 Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors
BS EN 61672-1:2013 Electroacoustics. Sound level meters Specifications
BS EN 54-7:2001 Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization
BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
BS EN ISO 13943:2017 Fire safety. Vocabulary
BS EN 54-26:2015 Fire detection and fire alarm systems Carbon monoxide detectors. Point detectors
2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
BS 5839-9:2011 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
BS EN 60702-2 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS
BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
BS EN 54-3:2014 Fire detection and fire alarm systems Fire alarm devices. Sounders
BS EN 54-5 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
BS EN 50136-1 : 2012 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION SYSTEMS
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS 8434-2(2003) : 2003 METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY
BS EN 54-12:2015 Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam
BS EN 54-13:2017 Fire detection and fire alarm systems Compatibility and connectability assessment of system components
BS EN 12845:2015 Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
BS EN 54-10:2002 Fire detection and fire alarm systems Flame detectors. Point detectors
BS EN 50281-1-2:1999 Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures Selection, installation and maintenance
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings
BS 7974:2001 Application of fire safety engineering principles to the design of buildings. Code of practice
BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
BS ISO 7240-8:2014 Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor
BS EN 54-25:2008 Fire detection and fire alarm systems Components using radio links
BS EN 54-20:2006 Fire detection and fire alarm systems Aspirating smoke detectors
BS EN 54-11:2001 Fire detection and fire alarm systems Manual call points
BS 7629-1:2008 Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire Multicore and multipair cables
IEC 60702-2:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.