BS EN 60076-1:2011
Current
The latest, up-to-date edition.
Power transformers General
Hardcopy , PDF
English
31-07-2012
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Rating and general requirements
6 Requirements for transformers having a tapped winding
7 Connection phase displacement symbols
8 Rating plates
9 Safety, environmental and other requirements
10 Tolerances
11 Tests
12 Electromagnetic compatibility (EMC)
13 High frequency switching transients
Annex A (informative) - Check list of information to be
provided with enquiry and order
Annex B (informative) - Examples of specifications for
transformers with tappings
Annex C (informative) - Specification of short-circuit
impedance by boundaries
Annex D (informative) - Examples of three-phase transformer
connections
Annex E (normative) - Temperature correction of load loss
Annex F (informative) - Facilities for future fitting of
condition monitoring systems to transformers
Annex G (informative) - Environmental and safety considerations
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Pertains to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers.
Committee |
PEL/14
|
DevelopmentNote |
Supersedes BS 171-1(1978) and BS 171-4(1978) (07/2001) Supersedes 01/206406 DC, 90/23125 and 97/204142 DC (07/2002) Supersedes 07/30167951 DC. (11/2011)
|
DocumentType |
Standard
|
Pages |
78
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60076 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers such as:
single-phase transformers with rated power less than 1 kVA and three-phase transformers less than 5 kVA;
transformers, which have no windings with rated voltage higher than 1 000 V;
instrument transformers;
traction transformers mounted on rolling stock;
starting transformers;
testing transformers;
welding transformers;
explosion-proof and mining transformers;
transformers for deep water (submerged) applications.
When IEC standards do not exist for such categories of transformers (in particular transformer having no winding exceeding 1000 V for industrial applications), this part of IEC 60076 may still be applicable either as a whole or in part.
This standard does not address the requirements that would make a transformer suitable for mounting in a position accessible to the general public.
For those categories of power transformers and reactors which have their own IEC standards, this part is applicable only to the extent in which it is specifically called up by cross-reference in the other standard. Such standards exist for:
reactors in general (IEC 60076-6);
dry-type transformers (IEC 60076-11);
self-protected transformers (IEC 60076-13);
gas-filled power transformers (IEC 60076-15);
transformers for wind turbine applications (IEC 60076-16);
traction transformers and traction reactors (IEC 60310);
converter transformers for industrial applications (IEC 61378-1);
converter transformers for HVDC applications (IEC 61378-2).
At several places in this part it is specified or recommended that an \'agreement\' should be reached concerning alternative or additional technical solutions or procedures. Such agreement is made between the manufacturer and the purchaser. The matters should preferably be raised at an early stage and the agreements included in the contract specification.
Standards | Relationship |
DIN EN 60076-1 : 2012 | Identical |
NF EN 60076-1 : 2012 | Identical |
I.S. EN 60076-1:2011 | Identical |
UNE-EN 60076-1:2013 | Identical |
SN EN 60076-1 : 1997 AMD 12 2002 | Identical |
IEC 60076-1:2011 | Identical |
NBN EN 60076-1 : 2011 | Identical |
EN 60076-1:2011 | Identical |
BS 6164:2011 | Code of practice for health and safety in tunnelling in the construction industry |
11/30218915 DC : DRAFT JAN 2011 | BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY |
BS 6164:2001 | Code of practice for safety in tunnelling in the construction industry |
IEC 60076-15:2015 | Power transformers - Part 15: Gas-filled power transformers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC TR 60616:1978 | Terminal and tapping markings for power transformers |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 62032:2012 | Guide for the Application, Specification and Testing of Phase-Shifting Transformers |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
IEEE C57.142 : 2010 | GUIDE TO DESCRIBE THE OCCURRENCE AND MITIGATION OF SWITCHING TRANSIENTS INDUCED BY TRANSFORMERS, SWITCHING DEVICE, AND SYSTEM INTERACTION |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC TS 60076-14:2009 | Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
IEC 60076-10-1:2016 | Power transformers - Part 10-1: Determination of sound levels - Application guide |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.