CSA C22.2 No. 60079-7 : 2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
Hardcopy , PDF
13-10-2021
English - French
01-10-2016
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Constructional requirements
5 Supplementary requirements for specific electrical equipment
6 Type verifications and type tests
7 Routine verifications and routine tests
8 Ex Component certificates
9 Marking and instructions
10 Documentation
Annex A (normative) - Temperature determination of electrical
machines - Methods of test and of calculation
Annex B (normative) - Type tests for specific forms of resistance
heating devices or resistance heating units (other than
trace heater)
Annex C (informative) - Cage motors - Thermal protection in
service
Annex D (informative) - Resistance heating devices and
units - Additional electrical protection
Annex E (informative) - Combinations of terminals and
conductors for general purpose connection and
junction boxes
Annex F (normative) - Dimensions of copper conductors
Annex G (normative) - Test procedure for T5 (only 8 W),T8,
T10 and T12 lamps
Annex H (normative) - Alternative separation distances for
Level of Protection ?ec
controlled environments
Annex I (informative) - Application, installation, and testing
considerations for Level of Protection ?ec
asynchronous machines
Annex J (informative) - Luminaires incorporating LEDs
Bibliography
This part of IEC 60079 specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety e intended for use in explosive gas atmospheres.
DevelopmentNote |
Supersedes CSA E60079.7. (04/2012)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0442-2
|
Pages |
269
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 60079-7:2015 | Identical |
CSA C22.2 No. 60079.1 : 2016 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
CSA CE CODE SAFETY PACKAGE : 2012 | CE CODE SAFETY PACKAGE |
CSA C22.2 No. 60079.1 : 2016 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
CSA C22.2 No. 60079-18 : 2016 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' |
CSA C22.2 No. 60079-11 : 2014 | EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I' |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60947-7-2:2009 | Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors |
CAN/CSA-C22.2 NO. 60079-30-1:17 | Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements (Adopted IEC/IEEE 60079-30-1:2015, first edition, 2015-09, with Canadian deviations) |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60317-3:2004+AMD1:2010 CSV | Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155 |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60079-30-2:2007 | Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance |
IEC 61347-2-13:2014+AMD1:2016 CSV | Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules |
IEC 60998-2-4:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-4: Particular requirements for twist-on connecting devices |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60050-411:1996 | International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
IEC 60317-8:2010 | Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180 |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
CSA C22.2 No. 60079.1 : 2016 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
IEC 62013-1:2005 | Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
IEC 61347-2-4:2000 | Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
CSA C22.2 No. 60529 : 2016 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) |
IEC 60044-6:1992 | Instrument transformers - Part 6: Requirements for protective current transformers for transient performance |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) | Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE) |
IEC TS 60034-25:2014 | Rotating electrical machines - Part 25: AC electrical machines used in power drive systems - Application guide |
IEC 60317-13:2010 | Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200 |
IEC 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 60079-35-1:2011 | Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion |
IEC TS 60034-17:2006 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
IEC 60034-18-41:2014 | Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests |
IEC 60079-29-2:2015 RLV | Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEC 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
IEEE 1349-2011 REDLINE | IEEE Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 954-1 : 1996 | SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 1: GENERAL PRINCIPLES FOR DESIGN |
IEC 60317-46:2013 | Specifications for particular types of winding wires - Part 46: Aromatic polyimide enamelled round copper wire, class 240 |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
IEC 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC 60432-3:2012 | Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle) |
ISO 178:2010 | Plastics Determination of flexural properties |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
IEC 61184:2017 | Bayonet lampholders |
IEC 60947-7-4:2013 | Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
IEC 60095-1:2006 | Lead-acid starter batteries - Part 1: General requirements and methods of test |
IEC 60622:2002 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.