EN IEC 61058-1:2018
Current
The latest, up-to-date edition.
Switches for appliances - Part 1: General requirements
25-05-2018
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General information on tests
6 Rating
7 Classification
8 Marking and documentation
9 Protection against electric shock
10 Provision for earthing
11 Terminals and terminations
12 Construction
13 Mechanism
14 Protection against ingress of solid foreign objects,
ingress of water and humid conditions
15 Insulation resistance and dielectric strength
16 Heating
17 Endurance
18 Mechanical strength
19 Screws, current-carrying parts and connections
20 Clearances, creepage distances, solid insulation
and coatings of rigid printed board assemblies
21 Fire hazard
22 Resistance to rusting
23 Abnormal operation and fault conditions for switches
24 Components for switches
25 EMC requirements
Annex A (normative) - Measurement of clearances and
creepage distances
Annex B (informative) - Diagram for the dimensioning of
clearances and creepage distances
Annex C (normative) - Proof tracking test
Annex D (informative) - Switch application guide
Annex E (normative) - Relation between rated impulse
withstand voltage, rated voltage and overvoltage
category
Annex F (normative) - Pollution degree
Annex G (normative) - Impulse voltage test
Annex H (normative) - Altitude correction factors
Annex I (normative) - Types of coatings for rigid printed
board assemblies
Annex J (normative) - Measuring the insulation distance of
a coated printed board with type 1 coating
Annex K (normative) - Routine tests
Annex L (informative) - Sampling tests
Annex M (normative) - Switch families
Annex N (informative) - Dimensions of tabs forming part
of a switch
Annex O (informative) - Common end product standards
Bibliography
Annex ZZA (informative) - Relationship between this
European Standard and the essential requirements
of Directive 2014/30/EU [2014 OJ L96] aimed to be
covered
Annex ZZB (informative) - Relationship between this
European standard and the safety objectives of
Directive 2014/35/EU [2014 OJ L96] aimed to be
covered
IEC 61058-1:2016 is available as IEC 61058-1:2016
RLV which contains the International Standard and its Redline
version, showing all changes of the technical content compared to
the previous edition.
IEC 61058-1:2016 applies to switches for appliances. The switches are intended to control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. This fourth edition cancels and replaces the third edition published in 2000, Amendment 1:2001 and Amendment 2:2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) requirements for mechanical switches are now given in IEC 61058-1-1;
b) requirements for electronic switches are now given in IEC 61058-1-2.
Committee |
CLC/SR 23J
|
DevelopmentNote |
Supersedes & Redesignates EN 61058-1. (06/2018)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
I.S. EN IEC 61058-1:2018 | Identical |
CEI EN IEC 61058-1 : 2019 | Identical |
CEI EN IEC 61058-1:2018 | Identical |
VDE 0630-1:2018-08 | Identical |
DIN EN IEC 61058-1 : 2018-08 | Identical |
UNE-EN IEC 61058-1:2019 | Identical |
IEC 61058-1:2016 | Identical |
BS EN IEC 61058-1:2018 | Identical |
PN EN IEC 61058-1 | Identical |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60730:1982 | Automatic controls for electrical household appliances |
IEC 60730-2-9:2015 RLV | Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60050-411:1996 | International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 60730-2-9:2010 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61058-1-1:2016 | Switches for appliances - Part 1-1: Requirements for mechanical switches |
EN 60738-1:2006/A1:2009 | THERMISTORS - DIRECTLY HEATED POSITIVE TEMPERATURE COEFFICIENT - PART 1: GENERIC SPECIFICATION |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60893-1:2004 | Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements |
EN 61058-1-2:2016 | Switches for appliances - Part 1-2: Requirements for electronic switches |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 60691:2016 | Thermal-links - Requirements and application guide |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 61058-1-1:2016 | Switches for appliances - Part 1-1: Requirements for mechanical switches |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61058-1-2:2016 | Switches for appliances - Part 1-2: Requirements for electronic switches |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 60038:2011 | CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.