• Shopping Cart
    There are no items in your cart

IEC 60502-1:2004+AMD1:2009 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-12-2018

Language(s)

English - French

Published date

25-11-2009

€400.27
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
   3.1 Definitions of dimensional values (thicknesses,
        cross-sections, etc.)
   3.2 Definitions concerning the tests
4 Voltage designations and materials
   4.1 Rated voltages
   4.2 Insulating compounds
   4.3 Sheathing compounds
5 Conductors
6 Insulation
   6.1 Material
   6.2 Insulation thickness
7 Assembly of multicore cables, inner coverings and fillers
   7.1 Inner coverings and fillers
   7.2 Cables with rated voltage 0,6/1 (1,2) kV
   7.3 Cables with rated voltage 1,8/3 (3,6) kV
8 Metallic layers for single-core and multicore cables
9 Metallic screen
   9.1 Construction
   9.2 Requirements
10 Concentric conductor
   10.1 Construction
   10.2 Requirements
   10.3 Application
11 Metallic sheath
   11.1 Lead sheath
   11.2 Other metallic sheaths
12 Metallic armour
   12.1 Types of metallic armour
   12.2 Materials
   12.3 Application of armour
   12.4 Dimensions of the armour wires and armour tapes
   12.5 Correlation between cable diameters and armour
        dimensions
   12.6 Round or flat wire armour
   12.7 Double tape armour
13 Oversheath
   13.1 General
   13.2 Material
   13.3 Thickness
14 Test conditions
   14.1 Ambient temperature
   14.2 Frequency and waveform of power frequency test
        voltages
   14.3 Waveform of impulse test voltages
15 Routine tests
   15.1 General
   15.2 Electrical resistance of conductors
   15.3 Voltage test
16 Sample tests
   16.1 General
   16.2 Frequency of sample tests
   16.3 Repetition of tests
   16.4 Conductor examination
   16.5 Measurement of thickness of insulation and of
        non-metallic sheaths (including extruded separation
        sheaths, but excluding inner extruded coverings)
   16.6 Measurement of thickness of lead sheath
   16.7 Measurement of armour wires and tapes
   16.8 Measurement of external diameter
   16.9 Hot set test for EPR, HEPR and XLPE insulations and
        elastomeric sheaths
17 Type tests, electrical
   17.1 Insulation resistance measurement at ambient temperature
   17.2 Insulation resistance measurement at maximum conductor
        temperature
   17.3 Voltage test for 4 h
   17.4 Impulse test for cables of rated voltage 1,8/3 (3,6) kV
18 Type tests, non-electrical
   18.1 Measurement of thickness of insulation
   18.2 Measurement of thickness of non-metallic sheaths
        (including extruded separation sheaths, but excluding
        inner coverings)
   18.3 Tests for determining the mechanical properties of
        insulation before and after ageing
   18.4 Tests for determining the mechanical properties of
        non-metallic sheaths before and after ageing
   18.5 Additional ageing test on pieces of completed cables
   18.6 Loss of mass test on PVC sheaths of type ST[2]
   18.7 Pressure test at high temperature on insulations and
        non-metallic sheaths
   18.8 Test on PVC insulation and sheaths and halogen free
        sheaths at low temperatures
   18.9 Test for resistance of PVC insulation and sheaths to
        cracking (heat shock test)
   18.10 Ozone resistance test for EPR and HEPR insulations
   18.11 Hot set test for EPR, HEPR and XLPE insulations and
         elastomeric sheaths
   18.12 Oil immersion test for elastomeric sheaths
   18.13 Water absorption test on insulation
   18.14 Fire tests
   18.15 Measurement of carbon black content of black PE
         oversheaths
   18.16 Shrinkage test for XLPE insulation
   18.17 Special bending test
   18.18 Determination of hardness of HEPR insulation
   18.19 Determination of the elastic modulus of HEPR insulation
   18.20 Shrinkage test for PE oversheaths
   18.21 Additional mechanical tests on halogen free oversheaths
   18.22 Water absorption test for halogen free oversheaths
19 Electrical tests after installation
Annex A (normative) - Fictitious calculation method for
        determination of dimensions of protective coverings
   A.1 General
   A.2 Method
Annex B (normative) - Rounding of numbers
   B.1 Rounding of numbers for the purpose of the fictitious
        calculation method
   B.2 Rounding of numbers for other purposes
Annex C (normative) - Determination of hardness of HEPR
        insulations
   C.1 Test piece
   C.2 Test procedure

IEC 60502-1:2004+A1:2009 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) for fixed installations such as distribution networks or industrial installations. This standard includes cables which exhibit properties of reduced flame spread, low levels of smoke emission and halogen-free gas emission when exposed to fire. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area), submarine use or shipboard application. This consolidated version consists of the second edition (2004) and its amendment 1 (2009). Therefore, no need to order amendment in addition to this publication.

Committee
TC 20
DevelopmentNote
Supersedes IEC 60502 (03/2001) Stability Date: 2018. (09/2017)
DocumentType
Standard
ISBN
9782889102006
Pages
110
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

05/30128938 DC : DRAFT FEB 2005 IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
BS 8450:2006 Code of practice for installation of electrical and electronic equipment in ships
BS 7889:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations
CEI EN 50525-2-51 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN ISO 12696:2016 Cathodic protection of steel in concrete
CEI EN 61138 : 2009 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
05/30136422 DC : DRAFT JULY 2005
EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
ISO/IEC 14543-3-5:2007 Information technology Home electronic system (HES) architecture Part 3-5: Media and media dependent layers Power line for network based control of HES Class 1
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
I.S. HD 603:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
CEI EN 60684-3-247 : 2012 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL
IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60684-3-247:2011+AMD1:2016 CSV Flexible insulating sleeving - Part 3 Specifications for individual types of sleeving - Sheet 247: Heatshrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
EN 61138:2007 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
EN 50525-2-51:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
CEI 18-64 : 2008 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES
EN 10257-1:2011 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables
HD 22.13 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
EN ISO 12696:2016 Cathodic protection of steel in concrete (ISO 12696:2016)
BS 7856:2017 Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)
HD 22.12 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
HD 22.16 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
15/30301501 DC : 0 BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION
I.S. EN 61138:2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
12/30244462 DC : 0 BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE
I.S. EN 50628:2016 ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
PREN 10257-1 : DRAFT 2008 ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES
BS IEC 60287-1-1 : 2006 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
IEC TR 61200-52:2013 Electrical installation guide - Part 52: Selection and erection of electrical equipment - Wiring systems
HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
I.S. HD 604:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
IEEE 45-7 : 2012 RECOMMENDED PRACTICE FOR ELECTRICAL INSTALLATIONS ON SHIPBOARD - AC SWITCHBOARDS
I.S. EN 10257-1:2011 ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES
VDE 0266 : 2000 COR 1 2006 POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES Uo/U 0,6/1 KV
DIN VDE 0266 : 2000 COR 1 2006 POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES U(INDEX)0/U 0,6/1 KV
PREN 50620 : DRAFT 2014 CHARGING CABLES FOR ELECTRIC VEHICLES
CEI EN 60811-100 : 2014 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 100: GENERAL
UNE-EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
14/30316181 DC : 0 BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
04/30111859 DC : 0 IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS
07/30127452 DC : DRAFT AUG 2007 BS ISO 13628-5 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
BS EN 60811-100:2012 Electric and optical fibre cables. Test methods for non-metallic materials General
13/30281948 DC : 0 BS 7856 - CODE OF PRACTICE FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY (MID ACCURACY CLASSES A AND B) FOR USE IN THE UK
API SPEC 17E : 2017 SPECIFICATION FOR SUBSEA UMBILICALS
I.S. HD 627:2003 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
IEC 61892-4:2007 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
04/30109460 DC : DRAFT FEB 2004 HD 22.16 S2 - WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
IEC 60092-352:2005 Electrical installations in ships - Part 352: Choice and installation of electrical cables
API 17E REDLINE : 2010 SPECIFICATION FOR SUBSEA UMBILICALS
I.S. HD 22.12:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
CEI 20-21/1-1 : 2007 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
NFC 32 902 : 1998 INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS
I.S. EN 61439-1:2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011)
BIS IS/IEC 62271-1 : 2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS
IEC 60227-6:2001 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections
BS EN 60684-3-247 : 2011 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011)
IEC TS 62100:2004 Cables for aeronautical ground lighting primary circuits
IEC 60092-351:2004 Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables
04/30123347 DC : DRAFT OCT 2004 IEC 61439-1 - LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
EEMUA 133 : 2011 SPECIFICATION FOR UNDERGROUND ARMOURED CABLE PROTECTED AGAINST SOLVENT PENETRATION AND CORROSIVE ATTACK
UNI EN 10257-1 : 2011 ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES
UNE 21123-1:2017 Industrial cables of rated voltage 0,6/1 kV. Part 1: PVC insulated and sheathed cables.
UNE-EN ISO 12696:2017 Cathodic protection of steel in concrete (ISO 12696:2016)
UNE 21123-5:2017 Electric cables for industrial use of rated voltage 0,6/1 kV. Part 5: EPR insulated and polyolefin sheathed cables.
UNI EN ISO 13628-5 : 2010 PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
15/30301443 DC : 0 BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
IEC 62677-3-101:2018 Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications
11/30214057 DC : 0 BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST
BS EN 50525-2-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation
PREN 50525-2-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-2-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
PREN 50525-2-51 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
BS EN 50525-2-51:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation
BS ISO 13628-5:2002 Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
UNE 211025:2017 Cables with intrinsic resistance to fire and intended for use in emergency circuits.
UNE 21031:2017 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Cables for general applications - Flexible cables having more than 5 conductors with polyvinyl chloride sheath.
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
ISO 14990-1:2016 Earth-moving machinery — Electrical safety of machines utilizing electric drives and related components and systems — Part 1: General requirements
I.S. EN 60684-3-247:2011 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL
I.S. EN 60811-100:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 100: GENERAL (IEC 60811-100:2012 (EQV))
API STD 17F : 2017 SUBSEA PRODUCTION CONTROL SYSTEMS
PREN 50628 : DRAFT 2014 ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
I.S. HD 22.16:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General
I.S. EN 50525-2-51:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
09/30204029 DC : 0 BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
BS EN 10257-1:2011 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables Land cables
ISO 12696:2016 Cathodic protection of steel in concrete
ISO 13628-5:2009 Petroleum and natural gas industries Design and operation of subsea production systems Part 5: Subsea umbilicals
BS ISO 14990-1:2016 Earth-moving machinery. Electrical safety of machines utilizing electric drives and related components and systems General requirements
IEC 61439-1:2020 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
16/30301661 DC : 0 BS EN 61439-1 ED3.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
UNE-EN 10257-1:2012 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables
UNE-IEC 61892-4:2016 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
EN ISO 13628-5:2009 Petroleum and natural gas industries - Design and operation of subsea production systems - Part 5: Subsea umbilicals (ISO 13628-5:2009)
UNE 21161:2017 Cables for AGL constant current series circuits.
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN ISO 13628-5:2009 PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
BS EN IEC 62677-3-101:2018 Heat-shrinkable low and medium voltage moulded shapes Specification for individual materials. Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
14/30288755 DC : 0 BS EN 50620 - CHARGING CABLES FOR ELECTRIC VEHICLES
08/30188783 DC : 0 BS EN 50525-2-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
12/30244369 DC : 0 BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS
BS 8573:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire
UNE 21123-3:2017 Industrial cables of rated voltage 0,6/1 kV. Part 3: EPR insulated and PVC sheathed cables.
08/30189625 DC : 0 BS EN 10257-1 - ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES
BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
16/30348626 DC : 0 BS 7856:2017 - SPECIFICATION FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY FOR USE IN THE UK (ACCURACY CLASSES A AND B)
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
IEEE 1511.1 : 2010 GUIDE FOR INVESTIGATING AND ANALYZING SHIELDED POWER CABLE FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV
15/30324018 DC : 0 BS EN 62677-3-101 ED. 1.0 - HEAT SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: MATERIAL REQUIREMENTS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS
EN IEC 62677-3-101:2018 Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications
03/318201 DC : DRAFT NOV 2003 IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV)
04/30109444 DC : DRAFT FEB 2004 HD 22.13 S2 - HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
BS EN ISO 13628-5:2009 Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals
BS EN 61138:1998 Cables for portable earthing and short-circuiting equipment
UNE 21123-4:2017 Industrial cables of rated voltage 0,6/1kV. Part 4: XLPE insulated and polyolefin sheathed cables.
08/30188804 DC : 0 BS EN 50525-2-51 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
UNE 21123-2:2017 Industrial cables of rated voltage 0,6/1 kV. Part 2: XLPE insulated and PVC Sheathed cables.
DIN EN ISO 12696:2016-07 (Draft) CATHODIC PROTECTION OF STEEL IN CONCRETE (ISO 12696:2016)
I.S. EN IEC 62677-3-101:2018 HEAT-SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: SPECIFICATION FOR INDIVIDUAL MATERIALS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS
I.S. HD 22.13:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
UNE-EN 50525-2-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
UNE 21144-1-1:2012 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General
I.S. EN ISO 12696:2016 CATHODIC PROTECTION OF STEEL IN CONCRETE (ISO 12696:2016)
UNE-IEC 60092-352:2015 Electrical installations in ships - Part 352: Choice and installation of electrical cables
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50525-2-51:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
DIN EN 10257-1:2012-02 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables
I.S. EN 50525-2-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
IEC 61138:2007 Cables for portable earthing and short-circuiting equipment
EN 60684-3-247:2011/A1:2017 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011/A1:2016)
UNE-EN 61439-1:2012 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
BS EN 50628:2016 Erection of electrical installations in underground mines
BS EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies General rules
BS 7856:2013 Code of practice for special design and other features of alternating current watthour meters for active energy (MID accuracy classes A and B) for use in the UK
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
BS 6004:2000 Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
EN 50628:2016 Erection of electrical installations in underground mines
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 50525-2-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CSA ISO/IEC 14543-3-5 : 2008 INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1
CSA ISO/IEC 14543-3-5 : 2008 : R2013 INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1

IEC 60038:2009 IEC standard voltages
IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60228:2004 Conductors of insulated cables
IEC 60986:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
IEC 60754-1:2011 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
IEC 60230:1966 Impulse tests on cables and their accessories
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 60754-2:2011 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
ISO 48:2010 Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD)
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
IEC 60811-3-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.