IEC 60502-1:2004+AMD1:2009 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-12-2018
English - French
25-11-2009
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
3.1 Definitions of dimensional values (thicknesses,
cross-sections, etc.)
3.2 Definitions concerning the tests
4 Voltage designations and materials
4.1 Rated voltages
4.2 Insulating compounds
4.3 Sheathing compounds
5 Conductors
6 Insulation
6.1 Material
6.2 Insulation thickness
7 Assembly of multicore cables, inner coverings and fillers
7.1 Inner coverings and fillers
7.2 Cables with rated voltage 0,6/1 (1,2) kV
7.3 Cables with rated voltage 1,8/3 (3,6) kV
8 Metallic layers for single-core and multicore cables
9 Metallic screen
9.1 Construction
9.2 Requirements
10 Concentric conductor
10.1 Construction
10.2 Requirements
10.3 Application
11 Metallic sheath
11.1 Lead sheath
11.2 Other metallic sheaths
12 Metallic armour
12.1 Types of metallic armour
12.2 Materials
12.3 Application of armour
12.4 Dimensions of the armour wires and armour tapes
12.5 Correlation between cable diameters and armour
dimensions
12.6 Round or flat wire armour
12.7 Double tape armour
13 Oversheath
13.1 General
13.2 Material
13.3 Thickness
14 Test conditions
14.1 Ambient temperature
14.2 Frequency and waveform of power frequency test
voltages
14.3 Waveform of impulse test voltages
15 Routine tests
15.1 General
15.2 Electrical resistance of conductors
15.3 Voltage test
16 Sample tests
16.1 General
16.2 Frequency of sample tests
16.3 Repetition of tests
16.4 Conductor examination
16.5 Measurement of thickness of insulation and of
non-metallic sheaths (including extruded separation
sheaths, but excluding inner extruded coverings)
16.6 Measurement of thickness of lead sheath
16.7 Measurement of armour wires and tapes
16.8 Measurement of external diameter
16.9 Hot set test for EPR, HEPR and XLPE insulations and
elastomeric sheaths
17 Type tests, electrical
17.1 Insulation resistance measurement at ambient temperature
17.2 Insulation resistance measurement at maximum conductor
temperature
17.3 Voltage test for 4 h
17.4 Impulse test for cables of rated voltage 1,8/3 (3,6) kV
18 Type tests, non-electrical
18.1 Measurement of thickness of insulation
18.2 Measurement of thickness of non-metallic sheaths
(including extruded separation sheaths, but excluding
inner coverings)
18.3 Tests for determining the mechanical properties of
insulation before and after ageing
18.4 Tests for determining the mechanical properties of
non-metallic sheaths before and after ageing
18.5 Additional ageing test on pieces of completed cables
18.6 Loss of mass test on PVC sheaths of type ST[2]
18.7 Pressure test at high temperature on insulations and
non-metallic sheaths
18.8 Test on PVC insulation and sheaths and halogen free
sheaths at low temperatures
18.9 Test for resistance of PVC insulation and sheaths to
cracking (heat shock test)
18.10 Ozone resistance test for EPR and HEPR insulations
18.11 Hot set test for EPR, HEPR and XLPE insulations and
elastomeric sheaths
18.12 Oil immersion test for elastomeric sheaths
18.13 Water absorption test on insulation
18.14 Fire tests
18.15 Measurement of carbon black content of black PE
oversheaths
18.16 Shrinkage test for XLPE insulation
18.17 Special bending test
18.18 Determination of hardness of HEPR insulation
18.19 Determination of the elastic modulus of HEPR insulation
18.20 Shrinkage test for PE oversheaths
18.21 Additional mechanical tests on halogen free oversheaths
18.22 Water absorption test for halogen free oversheaths
19 Electrical tests after installation
Annex A (normative) - Fictitious calculation method for
determination of dimensions of protective coverings
A.1 General
A.2 Method
Annex B (normative) - Rounding of numbers
B.1 Rounding of numbers for the purpose of the fictitious
calculation method
B.2 Rounding of numbers for other purposes
Annex C (normative) - Determination of hardness of HEPR
insulations
C.1 Test piece
C.2 Test procedure
IEC 60502-1:2004+A1:2009 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) for fixed installations such as distribution networks or industrial installations. This standard includes cables which exhibit properties of reduced flame spread, low levels of smoke emission and halogen-free gas emission when exposed to fire. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area), submarine use or shipboard application. This consolidated version consists of the second edition (2004) and its amendment 1 (2009). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 20
|
DevelopmentNote |
Supersedes IEC 60502 (03/2001) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
ISBN |
9782889102006
|
Pages |
110
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
05/30128938 DC : DRAFT FEB 2005 | IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
CEI EN 50525-2-51 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION |
BS EN ISO 12696:2016 | Cathodic protection of steel in concrete |
CEI EN 61138 : 2009 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
NF EN 61138 : 2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
05/30136422 DC : DRAFT JULY 2005 | |
EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
ISO/IEC 14543-3-5:2007 | Information technology Home electronic system (HES) architecture Part 3-5: Media and media dependent layers Power line for network based control of HES Class 1 |
I.S. EN 60694:1999 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
I.S. HD 603:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
CEI EN 60684-3-247 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60684-3-247:2011+AMD1:2016 CSV | Flexible insulating sleeving - Part 3 Specifications for individual types of sleeving - Sheet 247: Heatshrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 61138:2007 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
EN 50525-2-51:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
CEI 18-64 : 2008 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES |
EN 10257-1:2011 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
HD 22.13 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
EN ISO 12696:2016 | Cathodic protection of steel in concrete (ISO 12696:2016) |
BS 7856:2017 | Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B) |
HD 22.12 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES |
HD 22.16 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
I.S. EN 61138:2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
PREN 10257-1 : DRAFT 2008 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
BS IEC 60287-1-1 : 2006 | ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL |
IEC TR 61200-52:2013 | Electrical installation guide - Part 52: Selection and erection of electrical equipment - Wiring systems |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
UNE-EN 50525-3-21:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
I.S. HD 604:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
IEEE 45-7 : 2012 | RECOMMENDED PRACTICE FOR ELECTRICAL INSTALLATIONS ON SHIPBOARD - AC SWITCHBOARDS |
I.S. EN 10257-1:2011 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
VDE 0266 : 2000 COR 1 2006 | POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES Uo/U 0,6/1 KV |
DIN VDE 0266 : 2000 COR 1 2006 | POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES U(INDEX)0/U 0,6/1 KV |
PREN 50620 : DRAFT 2014 | CHARGING CABLES FOR ELECTRIC VEHICLES |
CEI EN 60811-100 : 2014 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 100: GENERAL |
UNE-EN 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
14/30316181 DC : 0 | BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
BS EN 50525-3-21:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
04/30111859 DC : 0 | IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS |
07/30127452 DC : DRAFT AUG 2007 | BS ISO 13628-5 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
BS EN 60811-100:2012 | Electric and optical fibre cables. Test methods for non-metallic materials General |
13/30281948 DC : 0 | BS 7856 - CODE OF PRACTICE FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY (MID ACCURACY CLASSES A AND B) FOR USE IN THE UK |
API SPEC 17E : 2017 | SPECIFICATION FOR SUBSEA UMBILICALS |
I.S. HD 627:2003 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
04/30109460 DC : DRAFT FEB 2004 | HD 22.16 S2 - WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
API 17E REDLINE : 2010 | SPECIFICATION FOR SUBSEA UMBILICALS |
I.S. HD 22.12:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES |
CEI 20-21/1-1 : 2007 | ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL |
NFC 32 902 : 1998 | INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS |
I.S. EN 61439-1:2011 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011) |
BIS IS/IEC 62271-1 : 2007 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS |
IEC 60227-6:2001 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections |
BS EN 60684-3-247 : 2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011) |
IEC TS 62100:2004 | Cables for aeronautical ground lighting primary circuits |
IEC 60092-351:2004 | Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables |
04/30123347 DC : DRAFT OCT 2004 | IEC 61439-1 - LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
EEMUA 133 : 2011 | SPECIFICATION FOR UNDERGROUND ARMOURED CABLE PROTECTED AGAINST SOLVENT PENETRATION AND CORROSIVE ATTACK |
UNI EN 10257-1 : 2011 | ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
UNE 21123-1:2017 | Industrial cables of rated voltage 0,6/1 kV. Part 1: PVC insulated and sheathed cables. |
UNE-EN ISO 12696:2017 | Cathodic protection of steel in concrete (ISO 12696:2016) |
UNE 21123-5:2017 | Electric cables for industrial use of rated voltage 0,6/1 kV. Part 5: EPR insulated and polyolefin sheathed cables. |
UNI EN ISO 13628-5 : 2010 | PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
11/30214057 DC : 0 | BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST |
BS EN 50525-2-21:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation |
PREN 50525-2-21 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
CEI EN 50525-2-21 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
PREN 50525-2-51 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
BS EN 50525-2-51:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation |
BS ISO 13628-5:2002 | Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals |
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors |
UNE 211025:2017 | Cables with intrinsic resistance to fire and intended for use in emergency circuits. |
UNE 21031:2017 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Cables for general applications - Flexible cables having more than 5 conductors with polyvinyl chloride sheath. |
CEI EN 50525-3-21 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
ISO 14990-1:2016 | Earth-moving machinery — Electrical safety of machines utilizing electric drives and related components and systems — Part 1: General requirements |
I.S. EN 60684-3-247:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
I.S. EN 60811-100:2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 100: GENERAL (IEC 60811-100:2012 (EQV)) |
API STD 17F : 2017 | SUBSEA PRODUCTION CONTROL SYSTEMS |
PREN 50628 : DRAFT 2014 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
I.S. HD 22.16:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES |
IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |
I.S. EN 50525-2-51:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION |
IEC 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
09/30204029 DC : 0 | BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
BS EN 10257-1:2011 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables Land cables |
ISO 12696:2016 | Cathodic protection of steel in concrete |
ISO 13628-5:2009 | Petroleum and natural gas industries Design and operation of subsea production systems Part 5: Subsea umbilicals |
BS ISO 14990-1:2016 | Earth-moving machinery. Electrical safety of machines utilizing electric drives and related components and systems General requirements |
IEC 61439-1:2020 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
16/30301661 DC : 0 | BS EN 61439-1 ED3.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
UNE-EN 10257-1:2012 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
UNE-IEC 61892-4:2016 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
EN ISO 13628-5:2009 | Petroleum and natural gas industries - Design and operation of subsea production systems - Part 5: Subsea umbilicals (ISO 13628-5:2009) |
UNE 21161:2017 | Cables for AGL constant current series circuits. |
08/30188836 DC : 0 | BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE |
I.S. EN ISO 13628-5:2009 | PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS |
BS EN IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes Specification for individual materials. Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
I.S. EN 50525-3-21:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
14/30288755 DC : 0 | BS EN 50620 - CHARGING CABLES FOR ELECTRIC VEHICLES |
08/30188783 DC : 0 | BS EN 50525-2-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
UNE 21123-3:2017 | Industrial cables of rated voltage 0,6/1 kV. Part 3: EPR insulated and PVC sheathed cables. |
08/30189625 DC : 0 | BS EN 10257-1 - ZINC OR ZINC ALLOY COATED NON-ALLOY STEEL WIRE FOR ARMOURING EITHER POWER CABLES OR TELECOMMUNICATION CABLES - PART 1: LAND CABLES |
BS EN 60694:1997 | Common specifications for high-voltage switchgear and controlgear standards |
16/30348626 DC : 0 | BS 7856:2017 - SPECIFICATION FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY FOR USE IN THE UK (ACCURACY CLASSES A AND B) |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
IEEE 1511.1 : 2010 | GUIDE FOR INVESTIGATING AND ANALYZING SHIELDED POWER CABLE FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV |
15/30324018 DC : 0 | BS EN 62677-3-101 ED. 1.0 - HEAT SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: MATERIAL REQUIREMENTS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS |
EN IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
03/318201 DC : DRAFT NOV 2003 | IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV) |
04/30109444 DC : DRAFT FEB 2004 | HD 22.13 S2 - HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
BS EN ISO 13628-5:2009 | Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals |
BS EN 61138:1998 | Cables for portable earthing and short-circuiting equipment |
UNE 21123-4:2017 | Industrial cables of rated voltage 0,6/1kV. Part 4: XLPE insulated and polyolefin sheathed cables. |
08/30188804 DC : 0 | BS EN 50525-2-51 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION |
UNE 21123-2:2017 | Industrial cables of rated voltage 0,6/1 kV. Part 2: XLPE insulated and PVC Sheathed cables. |
DIN EN ISO 12696:2016-07 (Draft) | CATHODIC PROTECTION OF STEEL IN CONCRETE (ISO 12696:2016) |
I.S. EN IEC 62677-3-101:2018 | HEAT-SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: SPECIFICATION FOR INDIVIDUAL MATERIALS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS |
I.S. HD 22.13:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
UNE-EN 50525-2-21:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation |
UNE 21144-1-1:2012 | Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General |
I.S. EN ISO 12696:2016 | CATHODIC PROTECTION OF STEEL IN CONCRETE (ISO 12696:2016) |
UNE-IEC 60092-352:2015 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
PREN 50525-3-21 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
UNE-EN 50525-2-51:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation |
DIN EN 10257-1:2012-02 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
I.S. EN 50525-2-21:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
IEC 61138:2007 | Cables for portable earthing and short-circuiting equipment |
EN 60684-3-247:2011/A1:2017 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011/A1:2016) |
UNE-EN 61439-1:2012 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
BS EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies General rules |
BS 7856:2013 | Code of practice for special design and other features of alternating current watthour meters for active energy (MID accuracy classes A and B) for use in the UK |
EN 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
BS 6004:2000 | Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 50628:2016 | Erection of electrical installations in underground mines |
EN 50525-3-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
EN 50525-2-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
CSA ISO/IEC 14543-3-5 : 2008 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1 |
CSA ISO/IEC 14543-3-5 : 2008 : R2013 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1 |
IEC 60038:2009 | IEC standard voltages |
IEC 60811-3-1:1985 | Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60811-4-1:2004 | Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
IEC 60811-1-3:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
ISO 48:2010 | Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
IEC 60811-2-1:1998+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 60811-3-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.