IEC 60730-2-19:1997+AMD1:2000+AMD2:2007 CSV
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Automatic electrical controls for household and similar use - Part 2-19: Particular requirements for electrically operated oil valves, including mechanical requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English - French
21-11-2007
FOREWORD
1 Scope and normative references
2 Definitions
3 General requirements
4 General notes on tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Endurance
18 Mechanical strength
19 Threaded parts and connection
20 Creepage distances, clearances and distances through
solid insulation
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements - emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements - immunity
27 Abnormal operation
28 Guidance on the use of electronic disconnection
Figures
Annexes
This part 2 of IEC 60730 applies to electrically operated oil valves for use in, on or in association with equipment for household and similar use that use electricity, in combination with fuel in the liquid state such as distillates, residual fuels, etc. This part 2 also applies to electrically operated oil valves using NTC or PTC thermistors, requirements for which are contained in annex J. This consolidated version consists of the first edition (1997), its amendment 1 (2000) and its amendment 2 (2007). Therefore, no need to order amendments in addition to this publication.
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
NF EN 60730-2-19 : 2002 AMD 2 2008 | Identical |
GOST IEC 60730-2-19 : 2012 | Identical |
NEN EN IEC 60730-2-19 : 2002 AMD 2 2008 | Identical |
I.S. EN 60730-2-19:2002 | Identical |
VDE 0631-2-19 : 2009-01 | Identical |
DIN EN 60730-2-19 : 2009-01 | Identical |
BS EN 60730-2-19 : 2002 | Identical |
EN 60730-2-19:2002/A2:2008 | Identical |
UNE-EN 60730-2-19:2003 | Identical |
BS ISO 16110-1:2007 | Hydrogen generators using fuel processing technologies Safety |
BS EN 62282-3-1:2007 | Fuel cell technologies Stationary fuel cell power systems. Safety |
13/30279579 DC : 0 | BS ISO 19372 - MICROTURBINES APPLICATIONS - SAFETY |
NF ISO 16110-1 : 2009 | HYDROGEN GENERATORS USING FUEL PROCESSING TECHNOLOGIES - PART 1: SAFETY |
DIN EN ISO 23553-1:2014-09 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014); German version EN ISO 23553-1:2014 |
05/30060689 DC : DRAFT JUN 2005 | IEC 62282-3-1 - FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER PLANTS - SAFETY |
EN 62282-3-1 : 2007 | FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
I.S. EN 62282-3-1:2007 | FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
I.S. EN ISO 23553-1:2014 | SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL-BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES (ISO 23553-1:2014) |
ISO 16110-1:2007 | Hydrogen generators using fuel processing technologies Part 1: Safety |
UNE-EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014) |
UNI EN ISO 23553-1 : 2014 | SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL-BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES |
UNE-EN 62282-3-1:2011 | Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety |
BS EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances. Particular requirements Automatic and semi-automatic valves |
ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances Particular requirements Part 1: Automatic and semi-automatic valves |
12/30250105 DC : 0 | BS ISO 23553-1 - SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES (ISO/DIS 23553-1:2012) |
BS ISO 19372:2015 | Microturbines applications. Safety |
UNE-ISO 16110-1:2015 | Hydrogen generators using fuel processing technologies -- Part 1: Safety |
EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014) |
ISO 19372:2015 | Microturbines applications — Safety |
IEC 62282-3-1:2007 | Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
ISO 4400:1994 | Fluid power systems and components — Three-pin electrical plug connectors with earth contact — Characteristics and requirements |
IEC 60038:2009 | IEC standard voltages |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
ISO 274:1975 | Copper tubes of circular section — Dimensions |
IEC 60539:1976 | Directly heated negative temperature coefficient thermistors |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60730-2-14:2017 | Automatic electrical controls - Part 2-14: Particular requirements for electric actuators |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
ISO 7-1:1994 | Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60738-1-1:2008 | Thermistors - Directly heated positive step-function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application - Assessment level EZ |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60423:2007 | Conduit systems for cable management - Outside diameters of conduits for electrical installations and threads for conduits and fittings |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
ISO 7005-1:2011 | Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems |
ISO 301:2006 | Zinc alloy ingots intended for castings |
ISO 6952:1994 | Fluid power systems and components Two-pin electrical plug connectors with earth contact Characteristics and requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.