BS EN 60947-1 : 2007
Current
The latest, up-to-date edition.
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
Hardcopy , PDF
English
01-01-2007
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) - Harmonisation of utilization
categories for low-voltage switchgear and
controlgear
Annex B (informative) - Suitability of the equipment when
conditions for operation in service differ from the
normal conditions
Annex C (normative) - Degrees of protection of enclosed
equipment
Annex D (informative) - Examples of clamping units and
relationship between clamping unit and
connecting device
Annex E (informative) - Description of a method for adjusting
the load circuit
Annex F (informative) - Determination of short-circuit power-
factor or time-constant
Annex G (informative) - Measurement of creepage distances
and clearances
Annex H (informative) - Correlation between the nominal
voltage of the supply system and the rated impulse
withstand voltage of equipment
Annex J (informative) - Items subject to agreement between
manufacturer and user
Annex K (normative) - Procedure to determine reliability
data for electromechanicald devices use in functional
safety applications
Annex L (normative) - Terminal marking and distinctive
number
Annex M (normative) - Flammability test
Annex N (normative) - Requirements and tests for equipment with
protective separation
Annex O (informative) - Environmentally-conscious design
Annex P (informative) - Terminal lugs for low voltage
switchgear and controlgear connected to copper
conductors
Annex Q (normative) - Special tests - Damp heat, salt mist,
vibration and shock
Annex R (normative) - Application of the metal foil for
dielectric testing on accessible parts during operation
or adjustment
Annex S (normative) - Digital inputs and outputs
Annex T (normative) - Extended functions within electronic
overload relays
Annex U (informative) - Examples of control circuit
configurations
Annex V (informative) - Power management with switchgear
and controlgear for electrical energy efficiency
Annex W (normative) - Procedure to establish material
declaration
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
Annex ZZ (informative) Coverage of Essential Requirements
of EU Directives
Bibliography
Applicable to, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as 'equipment' and intended to be connected to circuits, the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.
Committee |
PEL/17/2
|
DevelopmentNote |
Supersedes 96/206168 DC, 96/207792 DC and 99/202934 DC (06/2002) Supersedes 02/206413 DC and 91/03179 DC (09/2004) Supersedes 98/203571 DC. (05/2005) Supersedes 08/30176293 DC.(05/2011) 2007 Edition Re-Issued in December 2014 & incorporates AMD 2 2014. Supersedes 11/30249097 DC. (01/2015)
|
DocumentType |
Standard
|
Pages |
268
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
|
Standards | Relationship |
I.S. EN 60947-1:2007 | Identical |
DIN EN 60947-1 : 2015 | Identical |
NBN EN 60947-1 : 2007 AMD 2 2015 | Identical |
UNE-EN 60947-1:2008 | Identical |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Identical |
NEN EN 60947-1 : AMD 11 95 | Identical |
NF EN 60947-1 : 2007 AMD 2 2015 | Identical |
EN 60947-1:2007/A2:2014 | Identical |
SN EN 60947-1 : 1999 AMD 1 2000 | Identical |
BS EN 147000:1995 | Harmonized system of quality assessment for electronic components. Generic specification. Sockets for use with electrical relays of assessed quality |
BS 7856:2017 | Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B) |
BS 6440:1999 | Powered lifting platforms for use by disabled persons. Code of practice |
BS 6440:2011 | Powered vertical lifting platforms having non-enclosed or partially enclosed liftways intended for use by persons with impaired mobility. Specification |
09/30181298 DC : 0 | BS 7657 - SPECIFICATION FOR FUSES (CUT-OUTS), ANCILLARY TERMINAL BLOCKS AND INTERCONNECTING UNITS UP TO 100 A RATING, FOR POWER SUPPLIES TO BUILDINGS |
09/30181290 DC : 0 | BS 7654 - SPECIFICATION FOR SINGLE-PHASE STREET LIGHTING FUSES (CUT-OUTS) FOR LOW-VOLTAGE PUBLIC ELECTRICITY DISTRIBUTION SYSTEMS - 25 A RATING FOR HIGHWAY POWER SUPPLIES AND STREET FURNITURE |
DEFSTAN 02-122/1(2002) : INTERIM | REQUIREMENTS FOR CATERING EQUIPMENT |
BS 7657:1993 | Specification for fuses (cut-outs), ancillary terminal blocks and interconnecting units up to 100 A rating, for power supplies to buildings |
93/210506 DC : DRAFT AUG 1993 | EN 50156 ELECTRICAL EQUIPMENT FOR FURNACES - PART 1 RULES FOR INSTALLATION (PREN 50156-1) |
BS 5900:2012 | Powered homelifts with partially enclosed carriers and no liftway enclosures. Specification |
BS 7654:1997 | Specification for single phase street lighting fuses (cut-outs) for low-voltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture |
BS 7654:2010 | Specification for single-phase street lighting cut-out assemblies for low-voltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture |
BS 6423:2014 | Code of practice for maintenance of low-voltage switchgear and controlgear |
13/30283398 DC : 0 | BS 7656+A1 - SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 315 ARATING |
ENA ER G81-2 : ISSUE 2 2016 | FRAMEWORK FOR NEW LOW VOLTAGE HOUSING DEVELOPMENT INSTALLATIONS - PART 2: MATERIALS SPECIFICATION |
DD ENV 1954:1997 | Internal and external fault behaviour of safety related electronic parts of gas appliances |
BS 7656(1993) : 1993 | SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 400 A RATING |
11/30194294 DC : 0 | BS 6440 - POWERED LIFTING PLATFORMS WITH NON-ENCLOSED LIFTWAYS FOR USE BY PERSONS WITH LIMITED MOBILITY - SPECIFICATION |
BS EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
14/30295814 DC : 0 | BS 8489-1 - FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
BS 7657:2010 | Specification for cut-out assemblies up to 100 A rating, for power supply to buildings |
BS DD8489-1(2011) : 2011 | FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
11/30194292 DC : 0 | BS 5900 - POWERED HOME LIFTS WITH FULLY OR PARTIALLY ENCLOSED CARS AND NO LIFT-WELL ENCLOSURES - SPECIFICATION |
ENA ER G81-5 : ISSUE 2 2016 | FRAMEWORK FOR NEW INDUSTRIAL AND COMMERCIAL UNDERGROUND CONNECTIONS - PART 5: MATERIALS SPECIFICATION |
16/30348626 DC : 0 | BS 7856:2017 - SPECIFICATION FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY FOR USE IN THE UK (ACCURACY CLASSES A AND B) |
BS EN 116000-3:1996 | Harmonized system of quality assessment for electronic components. Generic specification: electromechanical all-or-nothing relays Test and measurement procedures |
BS 8489-1:2016 | Fixed fire protection systems. Industrial and commercial watermist systems Code of practice for design and installation |
BS 4163:2007 | HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 4163:2000 | HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included) |
IEC TR 61912-1:2007 | Low-voltage switchgear and controlgear - Overcurrent protective devices - Part 1: Application of short-circuit ratings |
IEC 60947-6-2:2002+AMD1:2007 CSV | Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS) |
EN 60947-8:2003/A2:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 8: CONTROL UNITS FOR BUILT-IN THERMAL PROTECTION (PTC) FOR ROTATING ELECTRICAL MACHINES (IEC 60947-8:2003/A2:2011) |
IEC 60947-8:2003+AMD1:2006+AMD2:2011 CSV | Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines |
IEC 60228:2004 | Conductors of insulated cables |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
EN 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 61649:2008 | Weibull analysis |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
EN 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 60269-2:2013+AMD1:2016 CSV | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
IEC 62430:2009 | Environmentally conscious design for electrical and electronic products |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60092-504:2016 | Electrical installations in ships - Part 504: Automation, control and instrumentation |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
ISO 50001:2011 | Energy management systems Requirements with guidance for use |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
EN 61649:2008 | Weibull analysis |
EN 60216 : 1990 | |
WC 8:1988 | ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEC TR 62380:2004 | Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60050-603:1986 | International Electrotechnical Vocabulary (IEV) - Part 603: Generation, transmission and distribution of electricity - Power systems planning and management |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC TR 60344:2007 | Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 62430:2009 | Environmentally conscious design for electrical and electronic products |
IEC 60947-4-2:2011 | Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters |
EN 62061:2005/A2:2015 | SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 60269-2:1995/A2:2002 | LOW-VOLTAGE FUSES - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 61095:2009 | Electromechanical contactors for household and similar purposes |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 62474:2012 | Material declaration for products of and for the electrotechnical industry |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN ISO 13849-1:2015 | Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2015) |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60947-4-3:2014 | Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 62474:2012 | Material declaration for products of and for the electrotechnical industry |
EN 60695-2-2:1994/A1:1995 | FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
IEC 60981:2004 | Extra heavy-duty electrical rigid steel conduits |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.