BS EN 61058-1 : 2002
Current
The latest, up-to-date edition.
SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
Hardcopy , PDF
English
01-01-2008
1 Scope
2 Normative references
3 Definitions
3.1 General terms
3.2 Definitions relating to voltages, currents and
wattage
3.3 Definitions relating to the different types of
switches
3.4 Definitions relating to the operation of the
switch
3.5 Definitions relating to connections to the switch
3.6 Definitions relating to terminals and terminations
3.7 Definitions relating to insulation
3.8 Definitions relating to pollution
3.9 Definitions relating to manufacturers' tests
4 General requirements
5 General notes on tests
6 Rating
7 Classification
7.1 Classification of switches
7.2 Classification of terminals
8 Marking and documentation
9 Protection against electric shock
10 Provision for earthing
11 Terminals and terminations
11.1 Terminals for unprepared copper conductors
12 Construction
12.1 Constructional requirements relating to
protection against electric shock
12.2 Constructional requirements relating to
safety during mounting and normal operation
of the switch
12.3 Constructional requirements relating to the
mounting of switches and to the attachment of
cords
13 Mechanism
14 Protection against solid foreign objects, ingress of
water and humid conditions
14.1 Protection against ingress of solid foreign objects
14.2 Protection against ingress of dust
14.3 Protection against ingress of water
15 Insulation resistance and dielectric strength
16 Heating
16.1 General requirements
16.2 Contacts and terminals
16.3 Other parts
17 Endurance
17.1 General requirements
17.2 Electrical endurance tests
18 Mechanical strength
19 Screws, current-carrying parts and connections
19.1 General requirements for electrical connections
19.2 Screwed connections
19.3 Current-carrying parts
20 Clearances, creepage distances, solid insulation and
coatings of rigid printed board assemblies
20.1 Clearances
20.2 Creepage distances
20.3 Solid insulation
20.4 Coatings of rigid printed board assemblies
21 Fire hazard
21.1 Resistance to heat
21.2 Resistance to abnormal heat
22 Resistance to rusting
23 Abnormal operation and fault conditions for electronic
switches
24 Components for electronic switches
24.1 Protective devices
24.2 Capacitors
24.3 Resistors
25 EMC requirements
25.1 Immunity
25.2 Emission
Annex A (normative) - Measurement of clearances and creepage
distances
Annex B (informative) - Diagram for the dimensioning of
clearances and creepage distances
Annex D (normative) - Proof tracking test
Annex F (informative) - Switch application guide
Annex H (informative) - Flat quick-connect terminations,
method for selection of female
connectors
Annex K (normative) - Relation between rated impulse
withstand voltage, rated voltage
and overvoltage category
Annex L (normative) - Pollution degree
Annex M (normative) - Impulse voltage test
Annex N (normative) - Altitude correction factors
Annex P (normative) - Types of coatings for rigid printed
board assemblies
Annex Q (normative) - Measuring the insulation distance of
a coated printed board with type A
coating
Annex R (normative) - Routine tests
Annex S (informative) - Sampling tests
Annex T (informative) - Switch families
Annex U (normative) - Dimensions of tabs forming part of a
switch
Annex V (informative) - Requirements and tests for resistance
to abnormal heat for unattended
appliances
Annex ZA (informative) - Compliance checks to be carried out
for switches for appliances complying
with EN 61058-1:1992 + A1:1993
Annex ZB (normative) - Normative references to international
publications with their corresponding
European publications
Bibliography
Pertains to switches (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A.
Committee |
EPL/23
|
DevelopmentNote |
Partially supersedes BS 3955(1986). Supersedes 84/28029 DC. (02/2002) Supersedes 98/230650 DC. (10/2002) 2002 Edition Re-issued in June 2008 & incorporates AMD 2 2008. Supersedes 05/30136330 DC. (06/2008)
|
DocumentType |
Standard
|
Pages |
174
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 61058-1 : 2002 AMD 2 2008 | Identical |
SN EN 61058-1 : 1992 AMD 1 1993 | Identical |
DIN EN 61058-1 : 2008 COR 2 2011 | Identical |
EN 61058-1:2002/A2:2008 | Identical |
I.S. EN 61058-1:2002 | Identical |
NBN EN 61058-1 : 2002 AMD 1 2008 | Identical |
UNE-EN 61058-1:2004 | Identical |
BS 3535-1(1996) : 1996 | ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS |
BS EN 60742:1996 | Isolating transformers and safety isolating transformers. Requirements |
EN 60742:1995 | Isolating transformers and safety isolating transformers - Requirements |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60730-2-9:2015 RLV | Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60228:2004 | Conductors of insulated cables |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
IEC 61058-2-1:2010 | Switches for appliances - Part 2-1: Particular requirements for cord switches |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
HD 384.2 : 200S2 | INTERNATIONAL ELECTROTECHNICAL VOCABULARY - ELECTRICAL INSTALLATIONS OF BUILDINGS |
EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60050-411:1996 | International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 60730-2-9:2010 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 60738-1:2006/A1:2009 | THERMISTORS - DIRECTLY HEATED POSITIVE TEMPERATURE COEFFICIENT - PART 1: GENERIC SPECIFICATION |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60893-1:2004 | Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 60691:2016 | Thermal-links - Requirements and application guide |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
ISO 2081:2008 | Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel |
HD 630.3.1 S3:2002 | LOW-VOLTAGE FUSES - PART 3-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 4 |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC 61058-2-5:2010 | Switches for appliances - Part 2-5: Particular requirements for change-over selectors |
EN 61058-2-5:2011 | Switches for appliances - Part 2-5: Particular requirements for change-over selectors |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
ISO 1456:2009 | Metallic and other inorganic coatings — Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
HD 383 : S2 AMD 2 | CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS |
HD 566 : 200S1 | THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 61058-2-4:1995+AMD1:2003 CSV | Switches for appliances - Part 2-4: Particular requirements for independently mounted switches |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 2093:1986 | Electroplated coatings of tin — Specification and test methods |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
HD 625.3 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATINGS TO ACHIEVE INSULATION COORDINATION OF PRINTED BOARD ASSEMBLIES |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60617-2:1996 | Graphical symbols for diagrams - Partie 2: Symbol elements, qualifying symbols and other symbols having general application |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
EN 60893-1:2004 | Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements |
IEC 60269-3-1:2004 | Low-voltage fuses - Part 3-1: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.