Pipe threads where pressure tight joints are made on the threads - Part 2: Taper external threads and taper internal threads - Dimensions, tolerances and designation
17-08-2005
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and explanations
5 Dimensions
6 Designation
7 Thread design
7.1 Thread form
7.2 Thread lengths
8 Gauging
Bibliography
This document specifies the requirements for thread form, dimensions, tolerances and designation for jointing pipe threads, sizes 1/16 to 6 inclusive, for joints made pressure-tight by the mating of the threads. These threads are taper external and taper internal and are intended for use with pipes suitable for threading and for valves, fittings or other pipeline equipment interconnected by threaded joints.An appropriate thread sealant or jointing compound should be used on the thread to ensure pressure-tight joints.NOTE 1 Threaded joints using taper external threads and parallel internal threads are detailed in EN 10226-1.NOTE 2 The requirements for taper external threads are identical in EN 10226-1 and EN 10226-2.NOTE 3 For pipe threads where pressure-tight joints are not made on the threads see EN ISO 228-1.NOTE 4 EN 10226-3 gives details of recommended gauging systems for the verification of thread dimensions and thread form.
Committee |
CEN/TC 459/SC 10
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
BS EN 10226-2:2005 | Identical |
PN EN 10226-2 : 2007 | Identical |
UNE-EN 10226-2:2005 | Identical |
UNI EN 10226-2 : 2006 | Identical |
I.S. EN 10226-2:2005 | Identical |
NBN EN 10226-2 : 2005 | Identical |
NEN EN 10226-2 : 2005 | Identical |
NF EN 10226-2 : 2005 | Identical |
NS EN 10226-2 : 1ED 2005 | Identical |
DIN EN 10226-2:2005-11 | Identical |
PREN 498 : DRAFT 2009 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - BARBECUES FOR OUTDOOR USE CONTACT GRILLS INCLUDED |
BS EN 16678:2015 | Safety and control devices for gas burners and gas burning appliances. Automatic shut-off valves for operating pressure of above 500 kPa up to and including 6 300 kPa |
11/30238482 DC : 0 | BS EN 1458-1 - DOMESTIC DIRECT GAS-FIRED TUMBLE DRYERS OF TYPES B22D AND B23D, OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW - PART 1: SAFETY |
12/30259203 DC : 0 | BS EN 12007-5 - GAS INFRASTRUCTURE - PIPELINES FOR MAXIMUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES, SPECIFIC FUNCTIONAL REQUIREMENTS |
10/30227098 DC : 0 | BS EN 16125 - LPG EQUIPMENT AND ACCESSORIES - PIPEWORK SYSTEMS AND SUPPORTS - LPG LIQUID PHASE AND VAPOUR PRESSURE PHASE |
PREN 624 : DRAFT 2009 | SPECIFICATION FOR DEDICATED LPG APPLIANCES - ROOM SEALED LPG SPACE HEATING EQUIPMENT FOR INSTALLATION IN VEHICLES AND BOATS |
I.S. EN 12007-5:2014 | GAS INFRASTRUCTURE - PIPELINES FOR MAXIMUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES - SPECIFIC FUNCTIONAL REQUIREMENTS |
17/30363956 DC : 0 | BS EN 419 - GAS-FIRED OVERHEAD LUMINOUS RADIANT HEATERS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
I.S. EN 15502-1:2012 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 16678:2016 | Safety and control devices for gas burners and gas burning appliances - Automatic shut-off valves for operating pressure of above 500 kPa up to and including 6 300 kPa |
17/30332894 DC : 0 | BS EN 17082 - DOMESTIC AND NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
16/30334287 DC : 0 | BS EN 334 - GAS PRESSURE REGULATORS FOR INLET PRESSURE UP TO 100 BAR |
DIN EN 334:2016-05 (Draft) | GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR |
I.S. EN 14382:2005 | SAFETY DEVICES FOR GAS PRESSURE REGULATING STATIONS AND INSTALLATIONS - GAS SAFETY SHUT-OFF DEVICES FOR INLET PRESSURES UP TO 100 BAR |
DIN EN 416-1:2009-09 | SINGLE BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATERS FOR NON-DOMESTIC USE - PART 1: SAFETY |
DIN EN 777-1:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 1: SYSTEM D - SAFETY |
DIN EN ISO 23553-1:2014-09 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014); German version EN ISO 23553-1:2014 |
DIN EN 777-3:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
UNE-EN 525:2010 | Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW |
BS EN 624:2011 | Specification for dedicated LPG appliances. Room sealed LPG space heating equipment for installation in vehicles and boats |
BS EN 416-1:2009 | Single burner gas-fired overhead radiant tube heaters for non-domestic use Safety |
BS EN 14382 : 2005 | SAFETY DEVICES FOR GAS PRESSURE REGULATING STATIONS AND INSTALLATIONS - GAS SAFETY SHUT-OFF DEVICES FOR INLET PRESSURES UP TO 100 BAR |
BS EN 419-1:2009 | Non-domestic gas-fired overhead luminous radiant heaters Safety |
BS EN 1458-1:2011 | Domestic direct gas-fired tumble dryers of types B22D and B23D, of nominal heat input not exceeding 6 kW Safety |
EN 16129:2013 | Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixtures |
EN 12007-5:2014 | Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 5: Service lines - Specific functional requirements |
DIN EN 14543:2017-10 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - PARASOL PATIO HEATERS - FLUELESS RADIANT HEATERS FOR OUTDOOR OR AMPLY VENTILATED AREA USE |
EN 30-1-1:2008+A3:2013 | Domestic cooking appliances burning gas - Part 1-1: Safety - General |
EN 1319:2009 | Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW |
PREN 416 : DRAFT 2017 | GAS-FIRED OVERHEAD RADIANT TUBE HEATERS AND RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
09/30202316 DC : 0 | BS EN 12514-4 - PARTS FOR SUPPLY SYSTEMS FOR CONSUMING UNITS WITH LIQUID FUELS - PART 4: SAFETY REQUIREMENTS AND TESTS - PIPINGS AND PARTS WITHIN PIPELINES |
BS EN 12007-5:2014 | Gas infrastructure. Pipelines for maximum operating pressure up to and including 16 bar Service lines. Specific functional requirements |
BS EN 16129:2013 | Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixtures |
13/30286091 DC : 0 | BS EN 16678 - SAFETY AND CONTROL DEVICES FOR GAS BURNERS AND GAS BURNING APPLIANCES - AUTOMATIC SHUT-OFF VALVES FOR OPERATING PRESSURE OF ABOVE 500 KPA UP TO AND INCLUDING 6300 KPA |
17/30356713 DC | BS EN 88-3. Safety and control devices for gas burners and gas burning appliances. Part 3. Pressure and/or flow rate regulators for inlet pressures up to and including 500 kPa, electronic types |
PREN 16129 : DRAFT 2010 | PRESSURE REGULATORS, AUTOMATIC CHANGE-OVER DEVICES, HAVING A MAXIMUM REGULATED PRESSURE OF 4 BAR, WITH A MAXIMUM CAPACITY OF 100 KG/H, ASSOCIATED SAFETY DEVICES AND ADAPTORS FOR BUTANE, PROPANE, AND THEIR MIXTURES |
PREN 17175 : DRAFT 2017 | GAS-FIRED OVERHEAD RADIANT STRIP HEATERS AND MULTI-BURNER CONTINUOUS RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
UNI EN 12007-5 : 2014 | GAS INFRASTRUCTURE - PIPELINES FOR MAXIMUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES - SPECIFIC FUNCTIONAL REQUIREMENTS |
PREN 88-3 : DRAFT 2017 | SAFETY AND CONTROL DEVICES FOR GAS BURNERS AND GAS BURNING APPLIANCES - PART 3: PRESSURE AND/OR FLOW RATE REGULATORS FOR INLET PRESSURES UP TO AND INCLUDING 500 KPA, ELECTRONIC TYPES |
BS EN 50465:2015 | European product standard for combined heating power systems using gas fuel |
ONORM EN 334 : JUN 2009 | GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR |
I.S. EN 334:2005 | GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR |
PREN 30-1-1 : DRAFT 2017 | DOMESTIC COOKING APPLIANCES BURNING GAS - PART 1-1: SAFETY - GENERAL |
EN 50465 : 2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
I.S. EN 50465:2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
DIN EN 203-1:2014-07 | Gas heated catering equipment - Part 1: General safety rules |
DIN EN 1020:2010-05 | NON-DOMESTIC FORCED CONVECTION GAS-FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
DIN EN 1319:2010-06 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN-ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
DIN EN 14382:2016-05 (Draft) | SAFETY DEVICES FOR GAS PRESSURE REGULATING STATIONS AND INSTALLATIONS - GAS SAFETY SHUT-OFF DEVICES FOR INLET PRESSURES UP TO 100 BAR |
UNE-EN 1458-1:2012 | Domestic direct gas-fired tumble dryers of types B22D and B23D, of nominal heat input not exceeding 6 kW - Part 1: Safety |
BS EN 334 : 2005 | GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR |
BS EN 498:2012 | Specification for dedicated liquefied petroleum gas appliances. Barbecues for outdoor use contact grills included |
BS EN 1555-3 : 2010 | PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 3: FITTINGS |
I.S. EN 624:2011 | SPECIFICATION FOR DEDICATED LPG APPLIANCES - ROOM SEALED LPG SPACE HEATING EQUIPMENT FOR INSTALLATION IN VEHICLES AND BOATS |
DIN EN 1775:2007-10 | Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations |
I.S. EN 30-1-1:2008 | DOMESTIC COOKING APPLIANCES BURNING GAS - PART 1-1: SAFETY - GENERAL |
I.S. EN 1555-3:2010 | PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 3: FITTINGS |
I.S. EN 498:2012 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - BARBECUES FOR OUTDOOR USE CONTACT GRILLS INCLUDED |
DIN EN 13611:2019-06 | Safety and control devices for burners and appliances burning gaseous and/or liquid fuels - General requirements |
I.S. EN 14543:2017 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - PARASOL PATIO HEATERS - FLUELESS RADIANT HEATERS FOR OUTDOOR OR AMPLY VENTILATED AREA USE |
I.S. EN 203-1:2014 | GAS HEATED CATERING EQUIPMENT - PART 1: GENERAL SAFETY RULES |
I.S. EN 88-1:2011 | PRESSURE REGULATORS AND ASSOCIATED SAFETY DEVICES FOR GAS APPLIANCES - PART 1: PRESSURE REGULATORS FOR INLET PRESSURES UP TO AND INCLUDING 50 KPA |
I.S. EN 1458-1:2011 | DOMESTIC DIRECT GAS-FIRED TUMBLE DRYERS OF TYPES B22D AND B23D, OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW - PART 1: SAFETY |
I.S. EN 10255:2004 | NON-ALLOY STEEL TUBES SUITABLE FOR WELDING AND THREADING - TECHNICAL DELIVERY CONDITIONS |
I.S. EN 1775:2007 | GAS SUPPLY - GAS PIPEWORK FOR BUILDINGS - MAXIMUM OPERATING PRESSURE LESS THAN OR EQUAL TO 5 BAR - FUNCTIONAL RECOMMENDATIONS |
10/30228056 DC : 0 | |
11/30240282 DC : DRAFT MAR 2011 | BS EN 12828 - HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS |
09/30207446 DC : 0 | BS EN 498 - SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - BARBECUES FOR OUTDOOR USE CONTACT GRILLS INCLUDED |
DIN EN 12007-5:2014-07 | GAS INFRASTRUCTURE - PIPELINES FOR MAXIMIUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES - SPECIFIC FUNCTIONAL REQUIREMENTS |
15/30325369 DC : 0 | BS EN 484 - SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - INDEPENDENT STOVES, INCLUDING THOSE INCORPORATING A GRILL FOR OUTDOOR USE |
UNE-EN 16129:2014 | Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixtures |
12/30258147 DC : 0 | BS EN 203-1 - GAS HEATED CATERING EQUIPMENT - PART 1: GENERAL SAFETY RULES |
EN 1555-3:2010+A1:2012 | Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 3: Fittings |
PREN 10255 : DRAFT 2010 | NON-ALLOY STEEL TUBES SUITABLE FOR WELDING AND THREADING - TECHNICAL DELIVERY CONDITIONS |
UNI EN 1555-3 : 2013 | PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 3: FITTINGS |
I.S. EN 13611:2015 | SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS AND/OR LIQUID FUELS - GENERAL REQUIREMENTS |
DIN EN 1555-3:2013-01 | Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 3: Fittings (includes Amendment A1:2012) |
DIN EN 14543:2013-11 (Draft) | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - PARASOL PATIO HEATERS - FLUELESS RADIANT HEATERS FOR OUTDOOR OR AMPLY VENTILATED AREA USE |
BS EN 525:2009 | Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW |
BS EN 1020:2009 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
UNE-EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014) |
I.S. EN 777-4:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
I.S. EN 525:2009 | NON-DOMESTIC DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
I.S. EN 777-2:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
I.S. EN 416-1:2009 | SINGLE BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATERS FOR NON-DOMESTIC USE - PART 1: SAFETY |
I.S. EN 777-3:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
I.S. EN 1319:2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN-ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
I.S. EN 419-1:2009 | NON-DOMESTIC GAS-FIRED OVERHEAD LUMINOUS RADIANT HEATERS - PART 1: SAFETY |
I.S. EN 621:2009 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
UNE-EN 16125:2016 | LPG Equipment and Accessories - Pipework systems and supports - LPG in liquid phase and vapour pressure phase |
I.S. EN 778:2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
I.S. EN 1020:2009 | NON-DOMESTIC FORCED CONVECTION GAS-FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
I.S. EN 777-1:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 1: SYSTEM D - SAFETY |
UNI EN 416-1 : 2009 | SINGLE BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATERS FOR NON-DOMESTIC USE - PART 1: SAFETY |
UNI EN 1458-1 : 2012 | DOMESTIC DIRECT GAS-FIRED TUMBLE DRYERS OF TYPES B22D AND B23D, OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW - PART 1: SAFETY |
UNI EN 498 : 2012 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - BARBECUES FOR OUTDOOR USE CONTACT GRILLS INCLUDED |
EN 50465:2015 | Gas appliances - Combined heat and power appliance of nominal heat input inferior or equal to 70 kW |
UNI EN 778 : 2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
UNI EN 10255 : 2007 | NON-ALLOY STEEL TUBES SUITABLE FOR WELDING AND THREADING - TECHNICAL DELIVERY CONDITIONS |
UNI EN 777-4 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
UNI EN 624 : 2011 | SPECIFICATION FOR DEDICATED LPG APPLIANCES - ROOM SEALED LPG SPACE HEATING EQUIPMENT FOR INSTALLATION IN VEHICLES AND BOATS |
UNI EN 1020 : 2009 | NON-DOMESTIC FORCED CONVECTION GAS- FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
UNI EN 1775 : 2007 | GAS SUPPLY - GAS PIPEWORK FOR BUILDINGS - MAXIMUM OPERATING PRESSURE LESS THAN OR EQUAL TO 5 BAR - FUNCTIONAL RECOMMENDATIONS |
UNI EN 14382 : 2009 | SAFETY DEVICES FOR GAS PRESSURE REGULATING STATIONS AND INSTALLATIONS - GAS SAFETY SHUT-OFF DEVICES FOR INLET PRESSURES UP TO 100 BAR |
UNI EN ISO 23553-1 : 2014 | SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL-BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES |
UNI EN 1319 : 2010 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN- ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
UNI EN 621 : 2010 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
UNI EN 525 : 2009 | NON-DOMESTIC DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
UNI EN 777-1 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 1: SYSTEM D - SAFETY |
UNI EN 777-2 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
UNI EN 419-1 : 2009 | NON DOMESTIC GAS-FIRED OVERHEAD LUMINOUS RADIANT HEATERS - PART 1: SAFETY |
UNI EN 777-3 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
08/30191150 DC : 0 | BS EN 1555-3 - PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 3: FITTINGS |
UNI EN 16129 : 2013 | PRESSURE REGULATORS, AUTOMATIC CHANGE-OVER DEVICES, HAVING A MAXIMUM REGULATED PRESSURE OF 4 BAR, WITH A MAXIMUM CAPACITY OF 150 KG/H, ASSOCIATED SAFETY DEVICES AND ADAPTORS FOR BUTANE, PROPANE, AND THEIR MIXTURES |
PREN 484 : DRAFT 2015 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - INDEPENDENT STOVES, INCLUDING THOSE INCORPORATING A GRILL FOR OUTDOOR USE |
17/30363953 DC : 0 | BS EN 416 - GAS-FIRED OVERHEAD RADIANT TUBE HEATERS AND RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
PREN 203-1 : DRAFT 2012 | GAS HEATED CATERING EQUIPMENT - PART 1: GENERAL SAFETY RULES |
PREN 419 : DRAFT 2017 | GAS-FIRED OVERHEAD LUMINOUS RADIANT HEATERS FOR NONDOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
13/30276940 DC : 0 | BS EN 16125 - LPG EQUIPMENT AND ACCESSORIES - PIPEWORK SYSTEMS AND SUPPORTS - LPG LIQUID PHASE AND VAPOUR PRESSURE PHASE |
07/30163045 DC : DRAFT AUG 2007 | BS EN 525 - NON-DOMESTIC DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
09/30204183 DC : 0 | BS EN 88-1 - PRESSURE REGULATORS AND ASSOCIATED SAFETY DEVICES FOR GAS APPLIANCES - PART 1: PRESSURE REGULATORS FOR INLET PRESSURES UP TO AND INCLUDING 500 MBAR |
DIN EN 15502-1:2015-10 | Gas-fired heating boilers - Part 1: General requirements and tests (includes Amendment A1:2015) |
DIN EN 16125:2016-03 | LPG EQUIPMENT AND ACCESSORIES - PIPEWORK SYSTEMS AND SUPPORTS - LPG LIQUID PHASE AND VAPOUR PRESSURE PHASE |
I.S. EN 16125:2015 | LPG EQUIPMENT AND ACCESSORIES - PIPEWORK SYSTEMS AND SUPPORTS - LPG IN LIQUID PHASE AND VAPOUR PRESSURE PHASE |
I.S. EN ISO 23553-1:2014 | SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL-BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES (ISO 23553-1:2014) |
BS EN 16125:2015 | LPG Equipment and Accessories. Pipework systems and supports. LPG in liquid phase and vapour pressure phase |
17/30360051 DC : 0 | BS EN 13611 - SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS AND/OR LIQUID FUELS - GENERAL REQUIREMENTS |
UNE-EN 13611:2016 | Safety and control devices for burners and appliances burning gaseous and/or liquid fuels - General requirements |
DIN EN 13611:2016-09 | SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS AND/OR LIQUID FUELS - GENERAL REQUIREMENTS |
17/30363959 DC : 0 | BS EN 17175 - GAS-FIRED OVERHEAD RADIANT STRIP HEATERS AND MULTI-BURNER CONTINUOUS RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
DIN EN 525:2009-11 | NON-DOMESTIC DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
DIN EN 778:2010-03 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
DIN EN 88-1:2016-06 | Pressure regulators and associated safety devices for gas appliances - Part 1: Pressure regulators for inlet pressures up to and including 50 kPa (includes Amendment A1:2016) |
BS EN 778:2009 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
BS EN 621:2009 | Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products |
UNE-EN 498:2012 | Specification for dedicated liquefied petroleum gas appliances - Barbecues for outdoor use contact grills included |
BS EN 10255:2004 | Non-alloy steel tubes suitable for welding and threading. Technical delivery conditions |
BS EN 777-2:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System E. Safety |
BS EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances. Particular requirements Automatic and semi-automatic valves |
BS EN 88-1 : 2011 | PRESSURE REGULATORS AND ASSOCIATED SAFETY DEVICES FOR GAS APPLIANCES - PART 1: PRESSURE REGULATORS FOR INLET PRESSURES UP TO AND INCLUDING 50 KPA |
ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances Particular requirements Part 1: Automatic and semi-automatic valves |
12/30250105 DC : 0 | BS ISO 23553-1 - SAFETY AND CONTROL DEVICES FOR OIL BURNERS AND OIL BURNING APPLIANCES - PARTICULAR REQUIREMENTS - PART 1: AUTOMATIC AND SEMI-AUTOMATIC VALVES (ISO/DIS 23553-1:2012) |
BS EN 777-4:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System H. Safety |
BS EN 777-1:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System D. Safety |
UNE-EN 1020:2010 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
BS EN 203-1:2014 | Gas heated catering equipment General safety rules |
UNE-EN 30-1-1:2009 | Domestic cooking appliances burning gas - Part 1-1: Safety - General |
UNE-EN 14543:2006 | Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use |
UNE-EN 778:2010 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
UNE-EN 624:2011 | Specification for dedicated LPG appliances - Room sealed LPG space heating equipment for installation in vehicles and boats |
EN 1458-1:2011 | Domestic direct gas-fired tumble dryers of types B22D and B23D, of nominal heat input not exceeding 6 kW - Part 1: Safety |
EN 1775:2007 | Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations |
EN 14543:2017 | Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use |
EN 621:2009 | Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products |
EN 777-2:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 2: System E - Safety |
EN 16678:2015 | Safety and control devices for gas burners and gas burning appliances - Automatic shut-off valves for operating pressure of above 500 kPa up to and including 6 300 kPa |
EN 525:2009 | Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW |
EN 778:2009 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
EN 16125:2015 | LPG Equipment and Accessories - Pipework systems and supports - LPG in liquid phase and vapour pressure phase |
EN 416-1:2009 | Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 1: Safety |
EN 419-1:2009 | Non-domestic gas-fired overhead luminous radiant heaters - Part 1: Safety |
EN 498:2012 | Specification for dedicated liquefied petroleum gas appliances - Barbecues for outdoor use contact grills included |
EN 777-1:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 1: System D - Safety |
EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances - Particular requirements - Part 1: Automatic and semi-automatic valves (ISO 23553-1:2014) |
EN 334:2005+A1:2009 | Gas pressure regulators for inlet pressures up to 100 bar |
EN 777-3:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non domestic use - Part 3: System F - Safety |
EN 777-4:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 4: System H - Safety |
EN 624:2011 | Specification for dedicated LPG appliances - Room sealed LPG space heating equipment for installation in vehicles and boats |
UNI EN 203-1 : 2014 | GAS HEATED CATERING EQUIPMENT - PART 1: GENERAL SAFETY RULES |
12/30257022 DC : 0 | BS EN 13611 - SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS - GENERAL REQUIREMENTS |
09/30201902 DC : 0 | BS EN 624 - SPECIFICATION FOR DEDICATED LPG APPLIANCES - ROOM SEALED LPG SPACE HEATING EQUIPMENT FOR INSTALLATION IN VEHICLES AND BOATS |
DIN EN 16129:2013-08 | Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150kg/h, associated safety devices and adaptors for butane, propane, and their mixtures |
DIN EN 12007-5 E : 2014 | GAS INFRASTRUCTURE - PIPELINES FOR MAXIMUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES - SPECIFIC FUNCTIONAL REQUIREMENTS |
S.R. 12007-5:2016 | GUIDANCE ON THE APPLICATION OF I.S. EN 12007-5:2014, GAS INFRASTRUCTURE - PIPELINES FOR MAXIMUM OPERATING PRESSURE UP TO AND INCLUDING 16 BAR - PART 5: SERVICE LINES - SPECIFIC FUNCTIONAL REQUIREMENTS |
10/30233309 DC : 0 | BS EN 10255 - NON-ALLOY STEEL TUBES SUITABLE FOR WELDING AND THREADING - TECHNICAL DELIVERY CONDITIONS |
06/19977015 DC : DRAFT JULY 2006 | BS EN 10344 - MALLEABLE CAST IRON FITTINGS WITH COMPRESSION ENDS FOR STEEL PIPES |
DIN EN 16678:2016-02 | Safety and control devices for gas burners and gas burning appliances - Automatic shut-off valves for operating pressure of above 500 kPa up to and including 6 300 kPa |
BS EN 15502-1 : 2012 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 16129:2013 | PRESSURE REGULATORS, AUTOMATIC CHANGEOVER DEVICES, HAVING A MAXIMUM REGULATED PRESSURE OF 4 BAR, WITH A MAXIMUM CAPACITY OF 150 KG/H, ASSOCIATED SAFETY DEVICES AND ADAPTORS FOR BUTANE, PROPANE, AND THEIR MIXTURES |
UNI EN 334 : 2009 | GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR |
BS EN 13611:2015 | Safety and control devices for burners and appliances burning gaseous and/or liquid fuels. General requirements |
I.S. EN 16678:2015 | SAFETY AND CONTROL DEVICES FOR GAS BURNERS AND GAS BURNING APPLIANCES - AUTOMATIC SHUT-OFF VALVES FOR OPERATING PRESSURE OF ABOVE 500 KPA UP TO AND INCLUDING 6300 KPA |
PREN 13611 : DRAFT 2017 | SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS AND/OR LIQUID FUELS - GENERAL REQUIREMENTS |
DIN EN 498:2012-04 | Specification for dedicated liquefied petroleum gas appliances - Barbecues for outdoor use contact grills included |
DIN EN 624:2011-10 | Specification for dedicated LPG appliances - Room sealed LPG space heating equipment for installation in vehicles and boats |
DIN EN 777-4:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
DIN EN 777-2:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
DIN EN 419-1:2009-07 | NON-DOMESTIC GAS-FIRED OVERHEAD LUMINOUS RADIANT HEATERS - PART 1: SAFETY |
DIN EN 10255:2015-05 (Draft) | Non-Alloy steel tubes suitable for welding, threading and other joining methods - Requirements and test methods; German and English version prEN 10255:2015 |
DIN EN 30-1-1:2013-06 | Domestic cooking appliances burning gas - Part 1-1: Safety - General (includes Amendment 1:2013) |
BS EN 1775:2007 | Gas supply. Gas pipework for buildings. Maximum operating pressure less than or equal to 5 bar. Functional recommendations |
BS EN 14543:2017 | Specification for dedicated liquefied petroleum gas appliances. Parasol patio heaters. Flueless radiant heaters for outdoor or amply ventilated area use |
BS EN 1319:2009 | Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW |
BS EN 777-3:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System F. Safety |
BS EN 30-1-1 : 2008 | DOMESTIC COOKING APPLIANCES BURNING GAS - PART 1-1: SAFETY - GENERAL |
EN 88-1:2011+A1:2016 | Pressure regulators and associated safety devices for gas appliances - Part 1: Pressure regulators for inlet pressures up to and including 50 kPa |
DIN EN 621:2010-04 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
EN 1020:2009 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
DIN EN 10255:2007-07 | Non-alloy steel tubes suitable for welding and threading - Technical delivery conditions (includes Amendment A1:2007) |
I.S. EN 13611:2015/AC:2016 | SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS AND/OR LIQUID FUELS - GENERAL REQUIREMENTS |
EN 15502-1:2012+A1:2015 | Gas-fired heating boilers - Part 1: General requirements and tests |
DIN EN 1458-1:2012-02 | DOMESTIC DIRECT GAS-FIRED TUBLE DRYERS OF TYPES B22D AND B23D, OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW - PART 1: SAFETY |
UNI EN 30-1-1 : 2013 | DOMESTIC COOKING APPLIANCES BURNING GAS - PART 1-1: SAFETY - GENERAL |
EN 10255:2004+A1:2007 | Non-Alloy steel tubes suitable for welding and threading - Technical delivery conditions |
UNE-EN 16125:2020 | LPG Equipment and Accessories - Pipework systems and supports - LPG in liquid phase and vapour pressure phase |
UNE-EN 88-1:2012 | Pressure regulators and associated safety devices for gas appliances - Part 1: Pressure regulators for inlet pressures up to and including 50 kPa |
UNE-EN 1555-3:2011 | Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 3: Fittings |
NS-EN 88-1:2022+A1:2023 | Safety and control devices for gas burners and gas burning appliances - Part 1: Pressure regulators for inlet pressures up to and including 50 kPa |
UNE-EN 15502-1:2013 | Gas-fired heating boilers - Part 1: General requirements and tests |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
ISO 7-1:1994 | Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation |
EN 10226-3:2005 | Pipes threads where pressure tight joint are made on the threads - Part 3: Verification by means of limit gauges |
EN 10226-1:2004 | Pipe threads where pressure tight joints are made on the threads - Part 1: Taper external threads and parallel internal threads - Dimensions, tolerances and designation |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.