FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
25-10-2006
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 General requirements
5 General requirements for indications
5.1 Display of functional conditions
5.2 Display of indications
5.3 Indications on alphanumeric displays
5.4 Indication of the supply of power
5.5 Audible indications
5.6 Additional indications
6 The quiescent condition
7 The fire alarm condition
7.1 Reception and processing of fire signals
7.2 Indication of the fire alarm condition
7.3 Indication of the zones in alarm
7.4 Audible indication
7.5 Other indications during the fire alarm condition
7.6 Reset from the fire alarm condition
7.7 Output of the fire alarm condition
7.8 Output to fire alarm devices (option with
requirements)
7.9 Control of fire alarm routing equipment (options
with requirements)
7.10 Outputs to fire protection equipment (option with
requirements)
7.11 Delays to outputs (option with requirements)
7.12 Dependencies on more than one alarm signal
(options with requirement)
7.13 Alarm counter (option with requirements)
8 Fault warning condition
8.1 Reception and processing of fault signals
8.2 Indication of faults
8.3 Fault signals from points (option with
requirements)
8.4 Total loss of the power supply (option with
requirements)
8.5 System fault
8.6 Audible indication
8.7 Reset of fault indications
8.8 Fault output
8.9 Output to fault warning routing equipment
(option with requirements)
9 Disabled condition
9.1 General requirements
9.2 Indication of the disabled condition
9.3 Indication of specific disablements
9.4 Disablements and their indication
9.5 Disablement of addressable points (option with
requirements)
10 Test condition (option with requirements)
10.1 General requirements
10.2 Indication of the test condition
10.3 Indication of zones in the test state
11 Standardized input/output interface
(option with requirements)
12 Design requirements
12.1 General requirements and manufacturer's
declarations
12.2 Documentation
12.3 Mechanical design requirements
12.4 Electrical and other design requirements
12.5 Integrity of transmission paths
12.6 Accessibility of indications and controls
12.7 Indications by means of light emitting indicators
12.8 Indications on alphanumeric displays
12.9 Colours of indications
12.10 Audible indications
12.11 Testing of indicators
13 Additional design requirements for software controlled
control and indicating equipments
13.1 General requirements and manufacturer's
declarations
13.2 Software documentation
13.3 Software design
13.4 Program monitoring
13.5 The storage of programs and data
13.6 The monitoring of memory contents
13.7 Operation of the c.i.e. in the event of a
system fault
14 Marking
15 Tests
15.1 General
15.2 Functional test
15.3 Environmental tests
15.4 Cold (operational)
15.5 Damp heat, steady state (operational)
15.6 Impact (operational)
15.7 Vibration, sinusoidal (operational)
15.8 Electromagnetic Compatibility (EMC),
Immunity tests
15.13 Supply voltage variation (operational)
15.14 Damp heat, steady state (endurance)
15.15 Vibration, sinusoidal (endurance)
Annexes
A (informative) Explanation of access levels
B (informative) Optional functions with requirements
and alternatives
C (informative) Processing of signals from fire detectors
D (informative) Explanation of zones and the zonal indication
of fire alarms
E (informative) Delays to outputs
F (informative) Fault recognition and indication
G (informative) Standardized input/output interface
for the connection of ancillary equipment
(e.g. a fire brigade panel)
H (informative) Integrity of transmission paths
I (informative) Design requirements for software
controlled control and indicating equipments
ZA (informative) Clauses addressing the provisions of the EU
Construction Products Directive (89/106/EEC)
Bibliography
Defines requirements, test procedures and performance criteria for control and indicating equipment to be used in fire detecting and fire alarm systems installed in buildings.
Committee |
CEN/TC 72
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE 23007-2:1998 | Identical |
BS EN 54-2 : 1998 | Identical |
NEN EN 54-2 : 1999 AMD 1 2006 | Identical |
SN EN 54-2 : 1998 AMD 1 2006 | Identical |
NF EN 54-2 : 1997 AMD 1 2007 | Identical |
DIN EN 54-2:1997-12 | Identical |
I.S. EN 54-2:1999 | Identical |
PN EN 54-2 : 2002 AMD 1 2007 | Identical |
NS EN 54-2 : 1997 AMD 1 2006 | Identical |
BS EN 54-2 : 1997 | Identical |
UNI EN 54-2 : 2007 | Identical |
NBN EN 54-2 : 1998 AMD 1 2007 | Identical |
BS EN 54-2:1997+A1:2006 | Identical |
UNE-EN 54-22:2016 | Fire detection and fire alarm system - Part 22 : Resettable line-type heat detectors |
BS EN 54-16:2008 | Fire detection and fire alarm systems Voice alarm control and indicating equipment |
BS EN 54-31 : 2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
UNI CEN/TS 81-76 : 2013 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGERS AND GOODS PASSENGER LIFTS - PART 76: EVACUATION OF DISABLED PERSONS USING LIFTS |
PREN 54-20 : DRAFT 2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
PD CEN/TS 54-32:2015 | Fire detection and fire alarm systems Planning, design, installation, commissioning, use and maintenance of voice alarm systems |
DD CEN/TS 54-14:2004 | Fire detection and fire alarm systems Guidelines for planning, design, installation, commissioning, use and maintenance |
I.S. CEN TR 14568:2003 | EN 54 - FIRE DETECTION AND FIRE ALARM SYSTEMS - INTERPRETATION OF SPECIFIC CLAUSES OF EN 54-2:1997 |
PREN 54-12 : DRAFT 2009 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM |
UNE-EN 15089:2010 | Explosion isolation systems |
14/30274689 DC : 0 | BS EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
S.R. CEN/TS 81-76:2011 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGERS AND GOODS PASSENGER LIFTS - PART 76: EVACUATION OF DISABLED PERSONS USING LIFTS |
BS EN 54-13:2017 | Fire detection and fire alarm systems Compatibility and connectability assessment of system components |
CEN/TS 81-76:2011 | Safety rules for the construction and installation of lifts - Particular applications for passengers and goods passenger lifts - Part 76: Evacuation of disabled persons using lifts |
MIL-DTL-32525 Base Document:2016 | MAGAZINE, PORTABLE (SHIPBOARD) |
PREN 54-13 : DRAFT 2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
PREN 81-73 : DRAFT 2014 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGER AND GOODS PASSENGER LIFTS - PART 73: BEHAVIOUR OF LIFTS IN THE EVENT OF FIRE |
I.S. EN CLC TS 50398:2003 | ALARM SYSTEMS - COMBINED AND INTEGRATED ALARM SYSTEMS - GENERAL REQUIREMENTS |
14/30296469 DC : 0 | BS EN 81-73 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGER AND GOODS PASSENGER LIFTS - PART 73: BEHAVIOUR OF LIFTS IN THE EVENT OF FIRE |
DD CEN/TS 14816:2008 | Fixed firefighting systems. Water spray systems. Design and installation |
I.S. EN 54-29:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS |
05/30117311 DC : 0 | EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS AND SYSTEM REQUIREMENTS |
11/30240275 DC : 0 | BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS |
04/30104415 DC : DRAFT AUG 2004 | EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
DIN EN 54-29:2015-06 | Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
11/30241966 DC : 0 | DD CEN/TS 81 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGERS AND GOODS PASSENGER LIFTS - PART 76: EVACUATION OF DISABLED PERSONS USING LIFTS |
03/102595 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE |
PRCEN/TS 81-76 : DRAFT 2011 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGERS AND GOODS PASSENGER LIFTS - PART 76: EVACUATION OF DISABLED PERSONS USING LIFTS |
04/30119106 DC : DRAFT AUG 2004 | EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATERMIST SYSTEMS - DESIGN AND INSTALLATION |
ISA TR84.00.07 : 2010 | GUIDANCE ON THE EVALUATION OF FIRE AND GAS SYSTEM EFFECTIVENESS |
S.R. CEN/TS 54-32:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 32: PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE OF VOICE ALARM SYSTEMS |
UNE-CEN/TS 81-76:2012 | Safety rules for the construction and installation of lifts - Particular applications for passengers and goods passenger lifts - Part 76: Evacuation of disabled persons using lifts |
I.S. EN 54-22:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
IEC TR 61831:2011 | On-line analyser systems - Guide to design and installation |
EN 54-22:2015 | Fire detection and fire alarm systems - Part 22: Resettable line-type heat detectors |
UNE-EN 81-73:2016 | Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 73: Behaviour of lifts in the event of fire |
VDI 6010:2005-09 | Technical safety installations - System-overlapping functions |
VDI 6010 Blatt 2:2011-05 | Technical safety installations - Automation and control of fire protective services |
12/30256417 DC : 0 | BS EN 54-31 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
BS EN 54-22:2015 | Fire detection and fire alarm systems Resettable line-type heat detectors |
PD IEC/TR 61831:2011 | On-line analyser systems. Guide to design and installation |
DIN EN 15089:2009-07 | EXPLOSION ISOLATION SYSTEMS |
DIN EN 54-22:2015-07 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS |
BS EN 15089:2009 | Explosion isolation systems |
BS EN 54-25:2008 | Fire detection and fire alarm systems Components using radio links |
UNI EN 15089 : 2009 | EXPLOSION ISOLATION SYSTEMS |
CEN/TS 54-32:2015 | Fire detection and fire alarm systems - Part 32: Planning, design, installation, commissioning, use and maintenance of voice alarm systems |
EN 54-13:2017 | Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components |
UNI EN 54-16 : 2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 16: VOICE ALARM CONTROL AND INDICATING EQUIPMENT |
I.S. EN 54-13:2017 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
DIN EN 81-73:2016-06 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGER AND GOODS PASSENGER LIFTS - PART 73: BEHAVIOUR OF LIFTS IN THE EVENT OF FIRE |
BS EN 54-21:2006 | Fire detection and fire alarm systems Alarm transmission and fault warning routing equipment |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
I.S. EN 81-73:2016 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PARTICULAR APPLICATIONS FOR PASSENGER AND GOODS PASSENGER LIFTS - PART 73: BEHAVIOUR OF LIFTS IN THE EVENT OF FIRE |
EN 81-73:2016 | Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 73: Behaviour of lifts in the event of fire |
UNI EN 54-20 : 2006 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
UNE-EN 54-16:2010 | Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment |
07/30164493 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATIONS AND MAINTENANCE |
11/30240441 DC : 0 | BS EN 54-28 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESET TABLE LINE TYPE HEAT DETECTORS |
07/30158994 DC : 0 | BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: LINE TYPE HEAT DETECTORS |
09/30170243 DC : 0 | BS EN 54-12 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM |
04/30125922 DC : 0 | EN 15089 - EXPLOSION ISOLATION SYSTEMS |
14/30290848 DC : 0 | BS EN 54-13 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
97/541589 DC : DRAFT MAY 1997 | PREN 12845 - FIXED FIREFIGHTING SYSTEMS - AUTOMATIC SPRINKLER SYSTEMS - DESIGN AND INSTALLATION |
96/542173 DC : DRAFT AUG 1996 | PREN 54-13 - FIRE DETECTION AND ALARM SYSTEMS - SPECIFICATION FOR SYSTEM REQUIREMENTS |
PD CEN/TR 14568:2003 | EN 54. Fire detection and fire alarm systems. Interpretation of specific clauses of EN 54-2:1997 |
UNI EN 54-25 : 2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
I.S. CEN TS 54-14:2004 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 14: GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
PREN 54-4 : DRAFT 2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT |
PREN 54-22 : DRAFT 2011 | FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS |
15/30290856 DC : 0 | BS EN 54-4 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4 : POWER SUPPLY EQUIPMENT |
I.S. EN 54-16:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 16: VOICE ALARM CONTROL AND INDICATING EQUIPMENT |
DIN EN 54-13:2014-09 (Draft) | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
I.S. EN 54-25:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
EN 54-4:1997/A2:2006 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT |
BS EN 54-11:2001 | Fire detection and fire alarm systems Manual call points |
BS EN 12094-1:2003 | Fixed firefighting systems. Components for gas extinguishing systems Requirements and test methods for electrical automatic control and delay devices |
BS EN 54-20:2006 | Fire detection and fire alarm systems Aspirating smoke detectors |
DIN EN 54-20:2009-02 | Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors (includes Amendment AC:2008) |
BS EN 81-73:2016 | Safety rules for the construction and installation of lifts. Particular applications for passenger and goods passenger lifts Behaviour of lifts in the event of fire |
EN 54-29 : 2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS |
EN 54-21:2006 | Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment |
EN 14637:2007 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 54-16:2008 | Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment |
EN 15089:2009 | Explosion isolation systems |
EN 54-20:2006/AC:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
EN 54-11:2001/A1:2005 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS |
EN 54-31:2014+A1:2016 | Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors |
UNI CEN/TS 14816 : 2009 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
02/540287 DC : DRAFT MAR 2002 | BS EN 14373 - EXPLOSION SUPPRESSION SYSTEMS |
BS EN 54-29:2015 | Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of smoke and heat sensors |
04/30105620 DC : DRAFT OCT 2004 | EN 54-21 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 21: ALARM TRANSMISSION AND FAULT WARNING ROUTING EQUIPMENT |
00/104442 DC : DRAFT JUNE 2000 | PREN 13916 - FIRE RESISTING DOORSETS - REQUIREMENTS AND CLASSIFICATION |
03/117188 DC : DRAFT OCT 2003 | BS EN 12101-10 - SMOKE AND HEAT CONTROL SYSTEMS - PART 10: POWER SUPPLIES |
DD CEN/TS 81-76:2011 | Safety rules for the construction and installation of lifts. Particular applications for passengers and goods passenger lifts Evacuation of disabled persons using lifts |
03/317852 DC : 0 | BS EN 14816 - FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN AND INSTALLATION |
I.S. EN 15089:2009 | EXPLOSION ISOLATION SYSTEMS |
I.S. EN 54-31:2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
DIN EN 54-25:2015-10 (Draft) | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
S.R. CEN TS 14816:2008 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
BS EN 54-4:1998 | Fire detection and fire alarm systems Power supply equipment |
CEN/TR 14568:2003 | EN 54 - Fire detection and fire alarm systems - Interpretation of specific clauses of EN 54-2:1997 |
CEN/TS 14816:2008 | Fixed firefighting systems - Water spray systems - Design, installation and maintenance |
DIN EN 54-21:2006-08 | Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment |
EN 12094-1:2003 | Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices |
DIN EN 14637:2008-01 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
DIN EN 54-16:2008-06 | Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment |
EN 54-25:2008/AC:2012 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 54-7:2000/A2:2006 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 54-4:1997/A2:2006 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.