    Current The latest, up-to-date edition.

    HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)

    Available format(s): 

    Language(s): 

    Published date:  26-09-2014

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 General
    2 Normal and special service
       conditions
    3 Terms and definitions
    4 Ratings
    5 Design and construction
    6 Type tests
    7 Routine tests
    8 Guide to the selection of
       prefabricated substation
    9 Information to be given with
       enquiries, tenders and orders
    10 Transport, storage, installation,
       operation, maintenance
    11 Safety
    12 Influence of the product on the
       environment
    Annex AA (normative) - Internal arc
             fault - Method to verify the
             internal arc classification (IAC)
    Annex BB (normative) - Test to verify
             the sound level of a
             prefabricated substation
    Annex CC (normative) - Mechanical
             impact test
    Annex DD (informative) - Rating of
             transformers in an enclosure
    Annex EE (informative) - Examples of
             earthing circuits
    Annex FF (informative) - Characteristics of
             enclosure materials
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Defines the service conditions, rated characteristics, general structural requirements and test methods of high voltage/low voltage or low voltage/high voltage prefabricated substations, which are cable-connected, to be operated from inside (walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above 1 kV and up to and including 52 kV on the high voltage side, and for one or more transformers for service frequencies up to and including 60 Hz for outdoor installation at locations with public accessibility and where protection of personnel is provided.

    General Product Information - (Show below) - (Hide below)

    Committee TC 17AC
    Development Note Supersedes EN 61330. (02/2007)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 50541-1:2012 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    PD CLC/TR 62271-208:2010 High-voltage switchgear and controlgear Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
    I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
    UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    EN 62271-3:2015 High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
    EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    BS EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements
    EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
    VDI 2050 Blatt 5:2010-10 Requirements at technical equipment rooms - Electrical engineering
    BS EN 62271-3:2015 High-voltage switchgear and controlgear Digital interfaces based on IEC 61850
    NF EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    CLC/TR 62271-208 : 2010 High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
    CEI CLC/TR 62271-208 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 208: METHODS TO QUANTIFY THE STEADY STATE, POWER-FREQUENCY ELECTROMAGNETIC FIELDS GENERATED BY HV SWITCHGEAR ASSEMBLIES AND HV/LV PREFABRICATED SUBSTATIONS
    CEI EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    S.R. CLC/TR 62271-208:2010 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 208: METHODS TO QUANTIFY THE STEADY STATE, POWER-FREQUENCY ELECTROMAGNETIC FIELDS GENERATED BY HV SWITCHGEAR ASSEMBLIES AND HV/LV PREFABRICATED SUBSTATIONS
    PREN 50541-1 : DRAFT 2009 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
    09/30211604 DC : 0 BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    I.S. EN 50541-1:2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
    BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
    BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
    09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
    BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
    UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
    BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
    EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
    IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV Classification of environmental conditions - Part 1: Environmental parameters and their severities
    IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
    EN ISO 6508-1:2016 Metallic materials - Rockwell hardness test - Part 1: Test method (ISO 6508-1:2016)
    IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    ISO 11408:1999 Chemical conversion coatings Black oxide coating on iron and steel Specification and test methods
    ISO 1716:2010 Reaction to fire tests for products Determination of the gross heat of combustion (calorific value)
    EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    EN ISO 3231:1997 Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993)
    EN ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009)
    ISO 13732-1:2006 Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces
    IEC GUIDE 117:2010 Electrotechnical equipment - Temperatures of touchable hot surfaces
    CLC/TR 62271-208 : 2010 High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
    IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
    EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    ISO 6508-1:2016 Metallic materials — Rockwell hardness test — Part 1: Test method
    EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
    EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    EN 60076-13 : 2006 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
    EN ISO 1182:2010 Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010)
    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    EN ISO 2409:2013 Paints and varnishes - Cross-cut test (ISO 2409:2013)
    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods
    IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
    EN ISO 9227:2017 Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2017)
    IEC TR 62655:2013 Tutorial and application guide for high-voltage fuses
    ISO 1052:1982 Steels for general engineering purposes
    EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
    ISO 2081:2008 Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel
    ISO 1182:2010 Reaction to fire tests for products Non-combustibility test
    EN ISO 13732-1:2008 Ergonomics of the thermal environment - Methods for the assessment of human responses to contact with surfaces - Part 1: Hot surfaces (ISO 13732-1:2006)
    EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
    IEC TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions
    ISO 10546:1993 Chemical conversion coatings Rinsed and non-rinsed chromate conversion coatings on aluminium and aluminium alloys
    IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
    EN 60076-10:2016 Power transformers - Part 10: Determination of sound levels
    IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
    ISO/IEC Guide 51:2014 Safety aspects Guidelines for their inclusion in standards
    EN ISO 1460 : 1994 METALLIC COATINGS - HOT DIP GALVANIZED COATINGS ON FERROUS MATERIALS - GRAVIMETRIC DETERMINATION OF THE MASS PER UNIT AREA
    HD 478.2.4 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - SOLAR RADIATION AND TEMPERATURE
    EN 60721-2-2 : 2013 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    EN 61439-2 : 2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: POWER SWITCHGEAR AND CONTROLGEAR ASSEMBLIES (IEC 61439-2:2011)
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC TR 61641:2014 Enclosed low-voltage switchgear and controlgear assemblies - Guide for testing under conditions of arcing due to internal fault
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    ISO 1920-4:2005 Testing of concrete Part 4: Strength of hardened concrete
    EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
    CLC/TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    EN 60243-1:2013 ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013)
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    EN 206-1:2000/A2:2005 CONCRETE - PART 1: SPECIFICATION, PERFORMANCE, PRODUCTION AND CONFORMITY
    ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests
    IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC TR 62271-208:2009 High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
    EN 60059:1999/A1:2009
    IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
    ISO 1460:1992 Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area
    EN 60721-1:1995/A2:1995 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES
    IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
    IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
    IEC 60076-13:2006 Power transformers - Part 13: Self-protected liquid-filled transformers
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    ISO 2409:2013 Paints and varnishes Cross-cut test
    EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    EN ISO 1716:2010 Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010)
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
    EN 61180-1:1994 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
    EN 62271-4 : 2013 High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures
    ISO 3231:1993 Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide
    IEC 61439-2:2011 Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective