• Shopping Cart
    There are no items in your cart

IEC 61034-2:2005+AMD1:2013 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

26-11-2019

Language(s)

English - French

Published date

27-06-2013

€119.56
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Test assembly
6 Test procedure
7 Evaluation of test results
8 Retest procedure
9 Test report
Annex A (informative) - Guidance on the principles
        and use of smoke measurements
Annex B (informative) - Recommended performance
        requirement
Bibliography

IEC 61034-2:2005+A1:2013 Provides details of the test procedure to be employed for the measurement of the density of smoke emitted from cables burning under defined conditions. It describes the means of preparing and assembling cables for test, the method of burning the cables, and gives recommended requirements for evaluating test results. The principal changes with respect to the previous edition are as follows:
a) inclusion of cables down to 1 mm diameter;
b) inclusion of non-circular cables;
c) addition of guidance on testing cables above 80 mm diameter;
d) delineation of elements of the test report;
e) addition of guidance on the calculation for other parameters for fire safety engineering purposes;
f) removal of minor differences with equivalent CENELEC work to allow parallel voting with that body. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the third edition (2005) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication.

Committee
TC 20
DevelopmentNote
Stability Date: 2018. (10/2012)
DocumentType
Standard
Pages
32
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
BS EN 50411-3-8:2016 Fibre organizers and closures to be used in optical fibre communication systems. Product specifications Fibre management system, terminal equipment box type 1 for category C
IEC 62930:2017 Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
12/30211334 DC : 0 BS ISO 15791-1 - PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO/DIS 15791-1:2012)
UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
07/30164222 DC : 0 BS EN 60794-2-20 - OPTICAL FIBRE CABLES - PART 2-20: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR MULTI-FIBRE OPTICAL DISTRIBUTION CABLES
CEI EN 50143 : 2012 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
I.S. EN 62012-1:2002 MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENTS - PART 1: GENERIC SPECIFICATION
BS EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V
08/30188833 DC : 0 BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
06/30151267 DC : 0 BS ISO CD 10840 - PLASTICS - GUIDANCE FOR THE USE OF STANDARD FIRE TESTS
08/30188839 DC : 0 BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
17/30309558 DC : 0 BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES
09/30166429 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
08/30188842 DC : 0 BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
KTA 2101.3 : 2015(R2017) FIRE PROTECTION IN NUCLEAR POWER PLANTS - PART 3: FIRE PROTECTION OF MECHANICAL AND ELECTRICAL PLANT COMPONENTS
IEC 60092-376:2017 Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
S.R. HD 60364-4-42:2011 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
S.R. CLC/TS 50576:2016 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
IEC 60092-352:2005 Electrical installations in ships - Part 352: Choice and installation of electrical cables
BS EN 50575 : 2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
NFC 32 102-13 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
NF EN 50143 : 2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
03/318326 DC : DRAFT NOV 2003
BS EN ISO 15791-1:2013 Plastics. Development and use of intermediate-scale fire tests for plastics products General guidance
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 50411-3-5:2015 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-5: Wall outlet
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
EN 187103:2003 Family specification - Optical fibre cables for indoor applications
EN 50575:2014/A1:2016 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 50411-3-8:2016 Fibre organizers and closures to be used in optical fibre communication systems - Product specifications - Part 3-8: Fibre management system, terminal equipment box type 1 for category C
HD 60364-4-42 : 2011 AMD 1 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014)
EN 60702-1:2002/A1:2015 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015)
CEI 18-64 : 2008 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50525-3-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
HD 22.13 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
BS IEC 61196-9:2014 Coaxial communication cables Sectional specification for RF flexible cables
I.S. EN 60702-1:2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
I.S. EN 50575:2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
BS EN 50525-3-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
ISO 10840:2008 Plastics — Guidance for the use of standard fire tests
BS EN 50525-3-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
IEC 61196-9:2014 Coaxial communication cables - Part 9: Sectional specification for RF flexible cables
BS ISO 10840:2008 Plastics. Guidance for the use of standard fire tests
07/30164159 DC : 0 BS EN 60794-2-30 - OPTICAL FIBRE CABLES - PART 2-30: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR OPTICAL FIBRE RIBBON CABLES
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
CEI EN 50551-2 : 2014 SIMPLEX AND DUPLEX CABLES TO BE USED FOR CORDS - PART 2: DETAILED SPECIFICATION AND MINIMUM REQUIREMENTS FOR A 3,0 MM SIMPLEX RUGGEDISED SINGLE MODE FIBRE CABLE TO BE USED FOR PATCHCORDS/CORDS CATEGORY U
CEI EN 50525-3-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. HD 60364-4-42:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
I.S. EN 50411-3-5:2015 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-5: WALL OUTLET
I.S. HD 22.9:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI CLC/TS 50576 : 2015 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
IEC TS 60695-6-2:2005 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
UNE-IEC 60092-350:2015 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
BS EN 60695-6-1 : 2005 FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE
I.S. EN 50525-3-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50525-3-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 13501-6:2014 Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables
UNE-CLC/TS 50576:2017 Electric cables - Extended application of test results for reaction to fire
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50575 : DRAFT 2012 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
NF EN 60794-1-1 : 2002 OPTICAL FIBER CABLES - PART 1-1: GENERIC SPECIFICATION - GENERAL
S.R. CEN/TS 45545-2:2009 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
EN 60695-6-1:2005/A1:2010 FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE
IEC 60092-354:2014 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
IEC 60092-353:2016 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
IEC PAS 60794-2-50:2004 Optical fibre cables - Part 2-50: Indoor optical fibre cables - Family specification for simplex and duplex cables for use in patch cords
CEI EN 60695-6-2 : 2013 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS
IEC 60092-376:2017 RLV Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
PD IEC/TR 62222:2012 Fire performance of communication cables installed in buildings
I.S. EN ISO 15791-1:2013 PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO 15791-1:2014)
12/30273098 DC : 0 BS EN 60702-1:2002+A1 - MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
PREN 50525-3-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50618:2015 Electric cables for photovoltaic systems
10/30216687 DC : 0 BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
BS EN 50618:2014 Electric cables for photovoltaic systems (BT(DE/NOT)258)
17/30348256 DC : 0 BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
IEC 62821-1:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements
BS IEC 61892-3:2012 Mobile and fixed offshore units. Electrical installations Equipment
BS ISO/TR 11696-2:1999 Uses of reaction to fire test results Fire hazard assessment of construction products
BS EN 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments Generic specification
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50525-3-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
NF EN 187103 : 2003 FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS
UNE-IEC 60092-353:2017 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30131385 DC : DRAFT MAR 2005 IEC 61156-1 ED 3 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 1: GENERIC SPECIFICATION
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
NFC 32 102-9 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
I.S. EN 50551-2:2013 SIMPLEX AND DUPLEX CABLES TO BE USED FOR CORDS - PART 2: DETAILED SPECIFICATION AND MINIMUM REQUIREMENTS FOR A 3,0 MM SIMPLEX RUGGEDISED SINGLE MODE FIBRE CABLE TO BE USED FOR PATCHCORDS/CORDS CATEGORY U
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 13501-6:2014 Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables
IEC TR 60092-370:2009 Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables
BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
PREN 13501-6 : DRAFT 2017 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
UNI EN 13501-6 : 2014 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 13501-6:2014 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
I.S. EN 60695-6-2:2011 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011)
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
ISO/TR 10840:1993 Plastics Burning behaviour Guidance for development and use of fire tests
IEC 61196-4:2015 Coaxial communication cables - Part 4: Sectional specification for radiating cables
IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
IEC 60695-6-2:2011 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
IEC 60092-353:2016 RLV Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
UNE-HD 620-9E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5).
EN ISO 15791-1:2013 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)
UNI EN ISO 15791-1 : 2014 PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
EA 0052:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
CEI EN 62012-1 : 2003 MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENT - PART 1: GENERIC SPECIFICATION
UNI CEI CEN/TS 45545-2 : 2009 RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
12/30259025 DC : 0 BS EN 50575 - POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS ISO 15791-1 : 2002 AMD 15256 PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE
I.S. EN 60695-6-1:2005 FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE
DD CEN/TS 45545-2:2009 Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50525-3-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 187103:2003 FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS
UNE-EN 60695-6-2:2012 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
UNE-IEC 60092-376:2017 Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60092-350:2014 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
IEC 61196-11:2016 Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric
IEC 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification
DD IEC TS 60695-6-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS
UNE-EN ISO 15791-1:2014 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)
IEC 60695-6-1:2005+AMD1:2010 CSV Fire hazard testing - Part 6-1: Smoke obscuration - General guidance
IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
IEC TR 62222:2012 Fire performance of communication cables installed in buildings
10/30230568 DC : 0 BS EN 61892-3 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT
ISO 15791-1:2014 Plastics — Development and use of intermediate-scale fire tests for plastics products — Part 1: General guidance
UNE-IEC 61892-4:2016 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
PREN 50525-3-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
BS EN 187103:2003 Harmonized system of quality assessment for electronic components. Family specification. Optical fibre cables for indoor applications
04/30114758 DC : 0 IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
BIS IS/IEC 60794-1-1 : 2001 OPTICAL FIBRE CABLES - PART 1: GENERIC SPECIFICATION - SECTION 1: GENERAL
CEI EN 187103 : 2003 FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS
BS EN 50551-2:2013 Simplex and duplex cables to be used for cords Detailed specification and minimum requirements for a 3,0 mm simplex ruggedised single mode fibre cable to be used for patchcords/cords category U
UNE-EN 50525-3-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
BS 8492:2009 Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection
DIN EN 13501-6:2014-07 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
PREN 50525-3-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
BS EN 50411-3-5:2015 Fibre organisers and closures to be used in optical fibre communication systems. Product specifications Wall outlet
12/30265027 DC : 0 BS EN 61196-9 ED.1 - COAXIAL COMMUNICATION CABLES - PART 9: SECTIONAL SPECIFICATION FOR FLEXIBLE RF COAXIAL CABLES
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
NFC 32 201-15 : 2006 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
UNE-EN 50575:2015 Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements
05/30139161 DC : DRAFT SEP 2005 IEC 60794-2-42 - OPTICAL FIBRE CABLES - PART 2-42: INDOOR OPTICAL FIBRE CABLES - PRODUCT SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES WITH A4 FIBRES
IEC 62821-3:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
IEC 61892-4:2007 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50411-3-8:2016 FIBRE ORGANIZERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-8: FIBRE MANAGEMENT SYSTEM, TERMINAL EQUIPMENT BOX TYPE 1 FOR CATEGORY C
I.S. HD 22.13:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
UNE-IEC 60092-354:2015 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
UNE-EN 50143:2010 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
UNE-IEC 60092-352:2015 Electrical installations in ships - Part 352: Choice and installation of electrical cables
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
TS 105 175-1 : 2.0.0 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); PLASTIC OPTICAL FIBRE SYSTEM SPECIFICATIONS FOR 100 MBIT/S AND 1 GBIT/S
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
I.S. EN 50143:2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
ISO/TR 11696-2:1999 Uses of reaction to fire test results Part 2: Fire hazard assessment of construction products
DIN EN ISO 15791-1:2014-05 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)
BS EN 60695-6-2:2011 Fire hazard testing Smoke obscuration. Summary and relevance of test methods
HD 22-9 : 200S3 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
CEN/TS 45545-2:2009 Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50551-2:2013 Simplex and duplex cables to be used for cords - Part 2: Detailed specification and minimum requirements for a 3,0 mm simplex ruggedised single mode fibre cable to be used for patchcords/cords category U
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 60695-6-2:2011 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011)
EN 50525-3-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
CEI 18-58 : 2013 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT
EN 50618:2014 Electric cables for photovoltaic systems
UNE-HD 60364-4-42:2014 Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects

IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
AS/NZS IEC 60092.376:2020 Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60695-6-1:2005+AMD1:2010 CSV Fire hazard testing - Part 6-1: Smoke obscuration - General guidance
ISO 13943:2017 Fire safety — Vocabulary
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
AS/NZS 60092.354:2020 Electrical installations in ships Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60092-354:2014 (ED.3.0) MOD)
AS/NZS IEC 60092.353:2020 Electrical installations in ships Power cables for rated voltages 1 kV and 3 kV
IEC 61034-1:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.