IEC 61058-2-4:1995+AMD1:2003 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Switches for appliances - Part 2-4: Particular requirements for independently mounted switches
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French, English, French, Spanish, Castilian
18-03-2003
FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirement
5 General notes on tests
6 Rating
7 Classification
8 Marking and documentation
9 Protection against electric shock
10 Provision for earthing
11 Terminals an terminations
12 Construction
13 Mechanism
14 Protection against solid foreign objects, ingress of dust,
water, and humid conditions
15 Insulation resistance and dielectric strength
16 Heating
17 Endurance
18 Mechanical strength
19 Screws, current-carrying parts and connections
20 Clearances, creepage distances, solid insulation and coatings
of rigid printed board assemblies
21 Resistance to heat and fire
22 Resistance to rusting
23 Abnormal operation and fault conditions for electronic
switches
24 Components
25 EMC requirements
Annex R (normative) Routine tests
Annex S (informative) Sampling tests
Annex T (informative) Switch families
Figures
Tables
Applies to independently mounted switches for appliances actuatedby hand, by foot or by other human activity for use withappliances and other equipment for household and similar purposes,with a rated voltage not exceeding 440 V and a rated current notexceeding 63 A.This consolidated version consists of the first edition (1995) and its amendment 1 (2003). Therefore, no need to order amendment inaddition to this publication.
DevelopmentNote |
To be used in conjunction with IEC 61058-1. (03/2003) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
45
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
OVE/ONORM EN 61058-2-4 : 2006 | Identical |
NF EN 61058-2-4 : 2005 | Identical |
GOST IEC 61058-2-4 : 2012 | Identical |
NEN EN IEC 61058-2-4 : 2006 | Identical |
I.S. EN 61058-2-4:2005 | Identical |
PN EN 61058-2-4 : 2010 | Identical |
VDE 0630-2-4 : 2006 | Identical |
DIN EN 61058-2-4 : 2006 | Identical |
BS EN 61058-2-4:2005 | Identical |
UNE-EN 61058-2-4:2006 | Identical |
CEI EN 61058-2-4 : 2006 | Identical |
EN 61058-2-4:2005 | Identical |
13/30294866 DC : 0 | BS EN 61058-1 - SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61058-1:2002 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
BS EN 61058-1 : 2002 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61058.1 : 2009 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61058.1 : 2009 : R2014 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61058.1 : 2009 : INC : UPD 1 : 2013 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60730-2-9:2015 RLV | Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60417-1:2002 | Graphical symbols for use on equipment - Part 1: Overview and application |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60050-411:1996 | International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60364-4-442:1993+AMD1:1995+AMD2:1999 CSV | Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 442: Protection of low-voltage installations against temporary overvoltages and faults between high-voltage systems and earth |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60227-3:1993+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring |
IEC 60893-1:2004 | Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
ISO 2081:2008 | Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
ISO 1456:2009 | Metallic and other inorganic coatings — Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 2093:1986 | Electroplated coatings of tin — Specification and test methods |
IEC 60228A:1982 | First supplement - Conductors of insulated cables - Guide to the dimensional limits of circular conductors |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
IEC 60364-4-443:1995+AMD1:1998 CSV | Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60617-2:1996 | Graphical symbols for diagrams - Partie 2: Symbol elements, qualifying symbols and other symbols having general application |
IEC 60269-3-1:2004 | Low-voltage fuses - Part 3-1: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.