IEC 61513:2011
Current
The latest, up-to-date edition.
Nuclear power plants - Instrumentation and control important to safety - General requirements for systems
Hardcopy , PDF
English - French
25-08-2011
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Overall I&C safety life cycle
6 System safety life cycle
7 Overall integration and commissioning
8 Overall operation and maintenance
Annex A (informative) - Basic safety issues in the NPP
Annex B (informative) - Categorisation of functions and
classification of systems
Annex C (informative) - Qualitative defence approach
against CCF
Annex D (informative) - Relations of IEC 61508 with
IEC 61513 and standards of the nuclear
application sector
Annex E (informative) - Changes to be performed in later
revisions of SC 45A standards to adapt to this
version of IEC 61513
Bibliography
Instrumentation and control (I&C) systems important to safety may be implemented using conventional hard-wired equipment, computer-based (CB) equipment or by using a combination of both types of equipment (see Note 1). IEC 61513:2011 provides requirements and recommendations for the overall I&C architecture which may contain either or both technologies. The main technical changes with regard to the previous edition are as follows:
- alignment with the latest revisions of IAEA documents;
- alignment with new editions of IEC 60880, IEC 61226, IEC 62138, IEC 62340 and IEC 60987;
- alignment with significant advances of software engineering techniques;
- integration of requirements for staff training.
Committee |
TC 45/SC 45A
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
205
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 61513:2013 | Identical |
NEN EN IEC 61513 : 2013 | Identical |
NF EN 61513 : 2013 | Identical |
CEI EN 61513 : 2013 | Identical |
BS EN 61513:2013 | Identical |
DIN EN 61513 : 2013 | Identical |
VDE 0491-2 : 2013 | Identical |
PN EN 61513 : 2013 | Identical |
GOST R IEC 61513 : 2011 | Identical |
NEN IEC 61513 : 2001 | Identical |
DIN IEC 61513 : 2002 AMD 100 2005 | Identical |
UNE-EN 61513:2013 | Identical |
BS IEC 61513:2011 | Identical |
PNE-prEN 61513 | Identical |
CSA N290.0 & N290.1 PACKAGE : 2013 | CONSISTS OF N290.0-11, GENERAL REQUIREMENTS FOR SAFETY SYSTEMS OF NUCLEAR POWER PLANTS AND N290.1-13, REQUIREMENTS FOR THE SHUTDOWN SYSTEMS OF NUCLEAR POWER PLANTS |
CSA N290.8 : 2015 | TECHNICAL SPECIFICATION REQUIREMENTS FOR NUCLEAR POWER PLANT COMPONENTS |
IEEE 730-2014 | IEEE Standard for Software Quality Assurance Processes |
I.S. EN 60987:2015 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - HARDWARE DESIGN REQUIREMENTS FOR COMPUTER-BASED SYSTEMS |
IEC TR 63123:2017 | Nuclear power plants - Instrumentation, control and electrical power systems - Guidance for the application of IEC 63147:2017/IEEE Std 497™ -2016 in the IAEA / IEC framework |
BS IEC 60880-2:2000 | Software for computers important to safety for nuclear power plants Software aspects of defence against common cause failures, use of software tools and of pre-developed software |
IEC TR 62918:2014 | Nuclear power plants - Instrumentation and control important to safety - Use and selection of wireless devices to be integrated in systems important to safety |
IEC TR 62096:2009 | Nuclear power plants - Instrumentation and control important to safety - Guidance for the decision on modernization |
IEC 62808:2015+AMD1:2018 CSV | Nuclear power plants - Instrumentation and control systems important to safety - Design and qualification of isolation devices |
IEC 60671:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Surveillance testing |
BS IEC 62646:2016 | Nuclear power plants. Control rooms. Computer-based procedures |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEC TR 62987:2015 | Nuclear power plants - Instrumentation and control systems important to safety - Use of Failure Mode and Effects Analysis (FMEA) and related methods to support the justification of systems |
BS EN 61800-5-2:2017 | Adjustable speed electrical power drive systems Safety requirements. Functional |
EN 60671:2011 | Nuclear power plants - Instrumentation and control systems important to safety - Surveillance testing |
EN 62138:2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT FOR SAFETY - SOFTWARE ASPECTS FOR COMPUTER-BASED SYSTEMS PERFORMING CATEGORY B OR C FUNCTIONS |
EN 62566:2014 | Nuclear power plants - Instrumentation and control important to safety - Development of HDL-programmed integrated circuits for systems performing category A functions |
IEC 60737:2010 | Nuclear power plants - Instrumentation important to safety - Temperature sensors (in-core and primary coolant circuit) - Characteristics and test methods |
IEC 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
IEC 60860:2014 | Radiation protection instrumentation - Warning equipment for criticality accidents |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEC 62646:2016 | Nuclear power plants - Control rooms - Computer-based procedures |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
BS IEC 60988:2009 | Nuclear power plants. Instrumentation important to safety. Acoustic monitoring systems for detection of loose parts: Characteristics, design criteria and operational procedures |
IEC 60988:2009 | Nuclear power plants - Instrumentation important to safety - Acoustic monitoring systems for detection of loose parts: characteristics, design criteria and operational procedures |
IEC TR 62247:2003 | Nuclear power plants - Main control room design - A review of the application of IEC 60964 (1989) |
EN 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
EN 62765-1:2017 | Nuclear powers plants - Instrumentation and control important to safety - Management of ageing of sensors and transmitters - Part 1: Pressure transmitters |
NF EN 60709 : 2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
PD IEC/TR 62918:2014 | Nuclear power plants. Instrumentation and control important to safety. Use and selection of wireless devices to be integrated in systems important to safety |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
ISO 12749-5:2018 | Nuclear energy, nuclear technologies, and radiological protection — Vocabulary — Part 5: Nuclear reactors |
EN 61800-5-2:2017 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
BS EN 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes. Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
BS IEC 60568:2006 | Nuclear power plants. Instrumentation important to safety. In-core instrumentation for neutron fluence rate (flux) measurements in power reactors |
EN 60880:2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SOFTWARE ASPECTS FOR COMPUTER-BASED SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
BS EN 61226:2010 | Nuclear power plants. Instrumentation and control important to safety. Classification of instrumentation and control functions |
BS EN 60965:2016 | Nuclear power plants. Control rooms. Supplementary control room for reactor shutdown without access to the main control room |
EN 62808:2016 | Nuclear power plants - Instrumentation and control systems important to safety - Design and qualification of isolation devices |
EN 62340:2010 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for coping with Common Cause Failure (CCF) |
BS EN 62340:2010 | Nuclear power plants. Instrumentation and control systems important to safety. Requirements for coping with common cause failure (CCF) |
PD IEC/TR 61838:2009 | Nuclear power plants. Instrumentation and control important to safety. Use of probabilistic safety assessment for the classification of functions |
BS EN 62566:2014 | Nuclear power plants. Instrumentation and control important to safety. Development of HDL-programmed integrated circuits for systems performing category A functions |
BS EN 61772:2013 | Nuclear power plants. Control rooms. Application of visual display units (VDUs) |
IEC 61468:2000 | Nuclear power plants - In-core instrumentation - Characteristics and test methods of self-powered neutron detectors |
CSA N290.14 : 2015 | QUALIFICATION OF DIGITAL HARDWARE AND SOFTWARE FOR USE IN INSTRUMENTATION AND CONTROL APPLICATIONS FOR NUCLEAR POWER PLANTS |
EN 61226:2010 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
I.S. EN 61226:2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - CLASSIFICATION OF INSTRUMENTATION AND CONTROL FUNCTIONS |
EN 60987:2015 | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
BS EN 60880:2009 | Nuclear power plants. Instrumentation and control systems important to safety. Software aspects for computer-based systems performing category A functions |
BS IEC 60532:2010 | Radiation protection instrumentation. Installed dose rate meters, warning assemblies and monitors. X and gamma radiation of energy between 50 keV and 7 MeV |
BS IEC 62855:2016 | Nuclear power plants. Electrical power systems. Electrical power systems analysis |
BS EN 60709:2010 | Nuclear power plants. Instrumentation and control systems important to safety. Separation |
BS IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity General requirements |
BS IEC 61888:2002 | Nuclear power plants. Instrumentation important to safety. Determination and maintenance of trip setpoints |
BS IEC 60880:2006 | Nuclear power plants. Instrumentation and control systems important to safety. Software aspects for computer-based systems performing category A functions |
BS IEC 62342:2007 | Nuclear power plants. Instrumentation and control systems important to safety. Management of ageing |
PD IEC/TR 62987:2015 | Nuclear power plants. Instrumentation and control systems important to safety. Use of Failure Mode and Effects Analysis (FMEA) and related methods to support the justification of systems |
BS EN 60671:2011 | Nuclear power plants. Instrumentation and control systems important to safety. Surveillance testing |
BS EN 62138:2009 | Nuclear power plants. Instrumentation and control important for safety. Software aspects for computer-based systems performing category B or C functions |
BS EN 60964:2010 | Nuclear power plants. Control rooms. Design |
BS IEC 61504:2017 | Nuclear facilities. Instrumentation and control systems important to safety. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
DIN IEC 60880-2 : 2001 | NUCLEAR POWER PLANTS - SOFTWARE FOR COMPUTERS IMPORTANT TO SAFETY - PART 2: SOFTWARE ASPECTS OF DEFENCE AGAINST COMMON CAUSE FAILURES, USE OF SOFTWARE TOOLS AND OF PRE-DEVELOPED SOFTWARE |
BS IEC 60860:2014 | Radiation protection instrumentation. Warning equipment for criticality accidents |
BS EN 61500:2011 | Nuclear power plants. Instrumentation and control important to safety. Data communication in systems performing category A functions |
BS EN 62765-1:2017 | Nuclear powers plants. Instrumentation and control important to safety. Management of ageing of sensors and transmitters Pressure transmitters |
PD IEC/TR 62096:2009 | Nuclear power plants. Instrumentation and control important to safety. Guidance for the decision on modernization |
VDI/VDE 3528 Blatt 1:2017-06 | Requirements of commercial grade products and criteria for their use in the instrumentation and control systems important to safety in nuclear power plants - General part |
BS IEC 61772:2009 | Nuclear power plants. Control rooms. Application of visual display units (VDUs) |
I.S. EN 62808:2016 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - DESIGN AND QUALIFICATION OF ISOLATION DEVICES |
BS EN 60987:2015 | Nuclear power plants. Instrumentation and control important to safety. Hardware design requirements for computer-based systems |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
03/301759 DC : DRAFT JAN 2003 | IEC 60709 ED.2 - NUCLEAR POWER PLANTS - SEPARATION OF I&C SYSTEMS IMPORTANT TO SAFETY |
CSA C22.2 NO. 60947-4-1:14 (R2019) | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1) |
CAN/CSA-IEC/TS 62443-1-1:17 | Industrial communication networks — Network and system security — Part 1-1: Terminology, concepts and models (Adopted IEC technical specification 62443-1-1:2009, first edition, 2009-07) |
IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC 61800-5-2:2016 RLV | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
UNE-EN 60947-4-1:2011 | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
BS IEC 60737:2010 | Nuclear power plants. Instrumentation important to safety Temperature sensors (in-core and primary coolant circuit). Characteristics and test methods |
EN 61500:2011 | Nuclear power plants - Instrumentation and control important to safety - Data communication in systems performing category A functions |
IEC TR 63084:2017 | Nuclear power plants - Instrumentation and control important to safety - Platform qualification for systems important to safety |
IEC 60880-2:2000 | Software for computers important to safety for nuclear power plants - Part 2: Software aspects of defence against common cause failures, use of software tools and of pre-developed software |
BS EN 60947-4-1 : 2010 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
IEC TR 62235:2005 | Nuclear facilities - Instrumentation and control systems important to safety - Systems of interim storage and final repository of nuclear fuel and waste |
IEC 61772:2009 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
EN 60964:2010 | Nuclear power plants - Control rooms - Design |
EN 61772:2013 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
BS IEC 61468:2000 | Nuclear power plants. In-core instrumentation. Characteristics and test methods of self-powered neutron detectors |
BS IEC 62651:2013 | Nuclear power plants. Instrumentation important to safety.Thermocouples: characteristics and test methods |
NF EN 62138 : 2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT FOR SAFETY - SOFTWARE ASPECTS FOR COMPUTER-BASED SYSTEMS PERFORMING CATEGORY B OR C FUNCTIONS |
NF EN 61500 : 2011 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - DATA COMMUNICATION IN SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
BS EN 62808:2016 | Nuclear power plants. Instrumentation and control systems important to safety. Design and qualification of isolation devices |
BS IEC 60768:2009 | Nuclear power plants. Instrumentation important to safety. Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
PD IEC/TR 63084:2017 | Nuclear power plants. Instrumentation and control important to safety. Platform qualification for systems important to safety |
IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 1: General requirements |
IEC 62651:2013 | Nuclear power plants - Instrumentation important to safety - Thermocouples: characteristics and test methods |
IEC 62765-1:2015 | Nuclear powers plants - Instrumentation and control important to safety - Management of ageing of sensors and transmitters - Part 1: Pressure transmitters |
BS IEC 61225:2005 | Nuclear power plants. Instrumentation and control systems important to safety. Requirements for electrical supplies |
IEC 62566:2012 | Nuclear power plants - Instrumentation and control important to safety - Development of HDL-programmed integrated circuits for systems performing category A functions |
BS IEC 62671:2013 | Nuclear power plants. Instrumentation and control important to safety. Selection and use of industrial digital devices of limited functionality |
IEC 60568:2006 | Nuclear power plants - Instrumentation important to safety - In-core instrumentation for neutron fluence rate (flux) measurements in power reactors |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
BS IEC 60987:2007 | Nuclear power plants. Instrumentation and control important to safety. Hardware design requirements for computer-based systems |
EN 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
BS IEC/IEEE 62582-5:2015 | Nuclear power plants. Instrumentation and control important to safety. Electrical equipment condition monitoring methods Optical time domain reflectometry |
IEC 60964:2009 | Nuclear power plants - Control rooms - Design |
IEC TS 62443-1-1:2009 | Industrial communication networks - Network and system security - Part 1-1: Terminology, concepts and models |
IEC 60768:2009 | Nuclear power plants - Instrumentation important to safety - Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
IEC 62340:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for coping with common cause failure (CCF) |
IEC 62342:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Management of ageing |
IEC 61888:2002 | Nuclear power plants - Instrumentation important to safety - Determination and maintenance of trip setpoints |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
EN 60709:2010 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC TR 61838:2009 | Nuclear power plants - Instrumentation and control important to safety - Use of probabilistic safety assessment for the classification of functions |
IEC 62855:2016 | Nuclear power plants - Electrical power systems - Electrical power systems analysis |
IEC 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
BS IEC 61226 : 2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - CLASSIFICATION OF INSTRUMENTATION AND CONTROL FUNCTIONS |
I.S. EN 61800-5-2:2017 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-2: SAFETY REQUIREMENTS - FUNCTIONAL |
I.S. EN 60965:2016 | NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
I.S. EN 60947-4-1:2010 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009 (EQV)) |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 60671:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Surveillance testing |
IEC 62342:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Management of ageing |
IEEE 610 : 1991 | COMPUTER DICTIONARY - A COMPILATION OF IEEE STANDARD COMPUTER GLOSSARIES |
IEEE 828-2012 | IEEE Standard for Configuration Management in Systems and Software Engineering |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 61500:2009 | Nuclear power plants - Instrumentation and control important to safety - Data communication in systems performing category A functions |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 61069-1:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 1: Terminology and basic concepts |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
IEC 62381:2012 | Automation systems in the process industry - Factory acceptance test (FAT), site acceptance test (SAT), and site integration test (SIT) |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 62340:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for coping with common cause failure (CCF) |
IEC 60980:1989 | Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
ISO 8402:1994 | Quality management and quality assurance — Vocabulary |
IEC 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
ISO/IEC 12207:2008 | Systems and software engineering — Software life cycle processes |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60709:2004 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC 60964:2009 | Nuclear power plants - Control rooms - Design |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
ISO 10007:2017 | Quality management — Guidelines for configuration management |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.