IEEE 400-2012 REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
17-11-2023
English
05-06-2012
1. Overview
2. Normative references
3. Definitions, acronyms, and abbreviations
4. Safety awareness
5. General considerations for field-testing of cable
systems
6. Field testing methods
7. Applicability of testing methods
Annex A (informative) - Bibliography
Annex B (informative) - Test voltage levels and durations
Annex C (informative) - Information on applicability of
field testing methods from CDFI
Presents an overview of the various test methods available for evaluating the insulation of shielded cable systems in the field, and to assist cable owners in selecting one or more appropriate tests for a specific application.
Committee |
Insulated Conductors
|
DevelopmentNote |
Supersedes IEEE DRAFT 400. (09/2004) Also included in IEEE 400 Set (CD-ROM) dated 28/11/2012 with IEEE 400.1, IEEE 400.2 and IEEE 400.3. Also included in IEEE 400 Series dated 05/10//2013 with IEEE 400.1, IEEE 400.2 and IEEE 400.3. (10/2013)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-7266-8
|
Pages |
54
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) |
IEEE 844-2000 | IEEE Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and Vessels |
IEEE 1242-1999 | IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants |
IEEE DRAFT 1511 : D6.0 MAY 2000 | DRAFT GUIDE FOR INVESTIGATING AND ANALYZING POWER CABLE, JOINT, AND TERMINATION FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV |
IEEE 1234-2007 | IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
UFC 3-550-07 : 2017 | UNIFIED FACILITIES CRITERIA - OPERATION AND MAINTENANCE (O&M;): EXTERIOR POWER DISTRIBUTION SYSTEMS |
TM 5-811-1 : V19950228 | ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION |
NFPA 70B:2023 | Standard for Electrical Equipment Maintenance |
CSA C68.10 : 2014 | SHIELDED POWER CABLE FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS, 5-46 KV |
NETA ATS : 2017 | ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS |
IEEE DRAFT 525 : D15 2006 | DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS |
CSA M421 : 2011 | USE OF ELECTRICITY IN MINES |
IEEE DRAFT 1215 : D13 2001 | DRAFT GUIDE FOR THE APPLICATION OF SEPARABLE INSULATED CONNECTORS |
API SPEC 17E : 2017 | SPECIFICATION FOR SUBSEA UMBILICALS |
IEEE DRAFT 400.2 : D5 MAR 2000 | DRAFT GUIDE FOR FIELD TESTING OF SHIELDED POWER CABLE SYSTEMS USING VERY LOW FREQUENCY (VLF) |
IEEE 3007.2 : 2010 | This recommended practice covers the maintenance of industrial and commercial power systems. |
IEEE 1017-2013 | IEEE Recommended Practice for Field Testing Electric Submersible Pump Cable |
IEEE 3001.5-2013 | IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems |
CSA M421 : 2011 : R2016 | USE OF ELECTRICITY IN MINES |
IEEE 3001.2:2017 | IEEE Recommended Practice for Evaluating the Electrical Service Requirements of Industrial and Commercial Power Systems |
IEEE 422-2012 | IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities |
IEEE 690-2004 | IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations |
IEEE 1205-2014 | IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities |
IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
IEEE 1185-2010 | IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEEE 400.4-2015 | IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
IEEE 400.2-2013 REDLINE | IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) |
IEEE 1215-2013 REDLINE | IEEE Guide for the Application of Separable Insulated Connectors |
IEEE 1234-2019 | IEEE Guide for Fault-Locating Techniques on Shielded Power Cable Systems |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEEE 1366-2012 REDLINE | IEEE Guide for Electric Power Distribution Reliability Indices |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
NEMA WC 74 : 2012 | 5-46 KV SHIELDED POWER CABLE FOR USE IN THE TRANSMISSION AND DISTRIBUTION OF ELECTRIC ENERGY |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEEE 4-1995 | IEEE Standard Techniques for High-Voltage Testing |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
IEEE 400.1-2007 | IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage |
NETA ATS : 2017 | ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
IEEE 400.2-2013 REDLINE | IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) |
IEEE 1234-2007 | IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems |
IEEE 510-1983 | IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE 1617:2007 | DETECTION, MITIGATION, AND CONTROL OF CONCENTRIC NEUTRAL CORROSION IN MEDIUM-VOLTAGE UNDERGROUND CABLES |
ICEA S 94 649 : 2013 | CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV |
NFPA 70E : 2018 | ELECTRICAL SAFETY IN THE WORKPLACE |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
IEEE 404-2012 | IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60885-2:1987 | Electrical test methods for electric cables. Part 2: Partial discharge tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.