1 Overview
2 Normative references
3 Definitions
4 Service conditions
5 Ratings
6 Functional components
7 Temperature limitations and classification
of insulating materials
8 Test procedures
Annex A (informative) - Application guide
Annex B (informative) - Bibliography
This standard covers the following types and preferred ratings for enclosed low-voltage ac power circuit breakers: a) Stationary or drawout type of two-, three-, or four-pole construction with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V respectively b) Unfused or fused type c) Manually operated or power operated, with or without a trip system d) Fused drawout assemblies consisting of current-limiting fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit b...
| Committee |
Switchgear
|
| DevelopmentNote |
Supersedes IEEE C37.13A. (02/2016)
|
| DocumentType |
Standard
|
| ISBN |
978-1-5044-0592-8
|
| Pages |
94
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
| IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) (Color Book® Series) |
| IEEE C37.16-2009 | IEEE Standard for Preferred Ratings,Related Requirements, and Application Recommendations for Low-Voltage AC (635 V and below)and DC (3200 V and below) Power Circuit Breakers |
| IEEE 3004.8-2016 | IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems |
| NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
| IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
| IEEE C37.96-2012 | IEEE Guide for AC Motor Protection |
| MIL-G-19826 Revision F:1984 | Generator Set, Diesel Engine, Alternating Current , for Facilities Construction; 10 KW Through 1000 KW (Not Stocked) (S/S By CC-G-2745) |
| TM 5-811-1 : V19950228 | ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION |
| IEEE C37.17-2022 | IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers |
| IEEE C37.27-2015 | IEEE Guide for Low-Voltage AC (635 V and below) Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses |
| IEEE 421.3-2016 REDLINE | IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines |
| CC-G-2745 Base Document:1984 | GENERATOR SETS, DIESEL ENGINE, ALTERNATING CURRENT, FOR FACILITIES CONSTRUCTION; 10 KW THROUGH 1000 KW (NOT STOCKED) (NO S/S DOCUMENT) |
| IEEE DRAFT C37.108 : D6 98 | DRAFT GUIDE FOR THE PROTECTION OF NETWORK TRANSFORMERS |
| IEEE DRAFT C37.123 : D2 FEB 96 | DRAFT GUIDE TO SPECIFICATIONS FOR GAS-INSULATED ELECTRIC POWER SUBSTATION EQUIPMENT |
| IEEE 3004.5-2014 | IEEE Recommended Practice for the Application of Low-Voltage Circuit Breakers in Industrial and Commercial Power Systems |
| IEEE 45-7 : 2012 | RECOMMENDED PRACTICE FOR ELECTRICAL INSTALLATIONS ON SHIPBOARD - AC SWITCHBOARDS |
| ANSI C37.51 : 1989 | SWITCHGEAR - METAL-ENCLOSED LOW-VOLTAGE AC POWER - CIRCUIT BREAKER SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
| ANSI C37.50 : 1989 | SWITCHGEAR - LOW VOLTAGE AC POWER CIRCUIT BREAKERS USED IN ENCLOSURES - TEST PROCEDURES |
| NEMA PB 2:2011 | Deadfront Distribution Switchboards |
| IEEE 387-1995 | IEEE Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations |
| IEEE 421.3-1997 | IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines |
| IEEE C37.59-2007 | IEEE Standard Requirements for Conversion of Power Switchgear Equipment |
| API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) (Color Book® Series) |
| IEEE 3001.5-2013 | IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems |
| IEEE C37.20 : 69(R1981) | SWITCH GEAR ASSEMBLIES AND METAL-ENCLOSED BUS |
| IEEE C37.13.1-2006 | IEEE Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear |
| IEEE C37.10-2011 REDLINE | IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures |
| API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
| IEEE C37.82-1987 | IEEE Standard for the Qualification of Switchgear Assemblies for Class 1E Applications in Nuclear Power Generating Stations |
| IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
| IEEE C37.27-2008 REDLINE | IEEE Application Guide for Low-Voltage AC Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses |
| IEEE C37.17-2012 | IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers |
| IEEE C37.17-2012 | TRIP DEVICES FOR AC AND GENERAL PURPOSE DC LOW VOLTAGE POWER CIRCUIT BREAKERS |
| IEEE DRAFT C37.96 : D5 99 | DRAFT GUIDE FOR AC MOTOR PROTECTION |
| IEEE 551 : 2006 | CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
| API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
| API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| ASHRAE 90.4 : 2016 | ENERGY STANDARD FOR DATA CENTERS |
| IEEE C37.20.1-2015 REDLINE | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
| PIP ELEGL03 : 2016 | GUIDELINES FOR POWER SYSTEMS ANALYSIS |
| PIP ELSSG01 : 2010 | DESIGN AND FABRICATION OF LOW-VOLTAGE METAL-ENCLOSED AC POWER CIRCUIT BREAKER SWITCHGEAR |
| IEEE C37.13.1-2016 | IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker Switchgear |
| IEEE 3002.3-2018 | IEEE Recommended Practice for Conducting Short-Circuit Studies and Analysis of Industrial and Commercial Power Systems |
| IEEE C37.82-2017 | IEEE Standard for the Qualification of Switchgear Assemblies for Class 1E Applications in Nuclear Power Generating Stations |
| IEEE C37.14-2015 REDLINE | IEEE Standard for DC (3200 V and below) Power Circuit Breakers Used in Enclosures |
| IEEE C37.20.1-2015 REDLINE | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
| IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
| IEEE 1-2000 | IEEE Recommended Practice - General Principles for Temperature Limits in the Rating of Electrical Equipment and for the Evaluation of Electrical Insulation |
| IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
| IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
| ANSI C37.50 : 1989 | SWITCHGEAR - LOW VOLTAGE AC POWER CIRCUIT BREAKERS USED IN ENCLOSURES - TEST PROCEDURES |
| UL 248-8:3ED 2011-05-13 | Low-Voltage Fuses - Part 8: Class J Fuses |
| NEMA CP 1:2000 (R2008) | SHUNT CAPACITORS |
| IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) (Color Book® Series) |
| IEEE C37.20.10-2016 | IEEE Standard Definitions for AC (52 kV and below)and DC (3.2 kV and below) Switchgear Assemblies |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| UL 248-10:3ED 2011-05-13 | Low-Voltage Fuses - Part 10: Class L Fuses |
| UL 746A:6ED 2012-09-06 | Polymeric Materials - Short Term Property Evaluations |
| IEEE C37.24-2003 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
| IEEE C37.27-2008 REDLINE | IEEE Application Guide for Low-Voltage AC Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses |
| IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
| IEEE C37.17-2012 | IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers |
| IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
Access your standards online with a subscription
-