CSA E60079.0 : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - GENERAL REQUIREMENTS
Hardcopy , PDF
01-03-2007
English
01-01-2002
Clause
1 Scope
2 Normative references
3 Definitions and symbols
4 Apparatus grouping and temperature classification
5 Temperatures
6 Requirements for all electrical apparatus
7 Non-metallic enclosures and non-metallic parts of
enclosures
8 Enclosures containing light metals
9 Fasteners
10 Interlocking devices
11 Bushings
12 Materials used for cementing
13 Ex components
14 Connection facilities and terminal compartments
15 Connection facilities for earthing or bonding
conductors
16 Cable and conduit entries
17 Supplementary requirements for rotating electrical
machines
18 Supplementary requirements for switchgear
19 Supplementary requirements for fuses
20 Supplementary requirements for plugs and sockets
21 Supplementary requirements for luminaires
22 Supplementary requirements for caplights, caplamps
and handlamps
23 Type verifications and tests
24 Routine verifications and tests
25 Manufacturer's responsibility
26 Verifications and tests on modified or repaired
electrical apparatus
27 Marking
Annex A (informative) Subdivision of gases and vapours
according to their maximum experimental safe
gaps and minimum ignition currents
Annex B (normative) Ex cable entries
Annex C (normative) Clauses with which Ex components
shall comply
Annex D (informative) Example of rig for resistance to
impact test
Figures and Tables
Covers the protection techniques with respect to explosion hazard only, the CAN/CSAE60079 series of CSA Standards (based on the corresponding IEC Standards) must be used in conjunction with other applicable standards containing the appropriate electrical safety requirements for general use equipment.
DocumentType |
Standard
|
Pages |
128
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
Standards | Relationship |
IEC 60079-0:2011 | Similar to |
IEEE 303-2004 | IEEE Recommended Practice for Auxiliary Devices for Rotating Electrical Machines in Class I, Division 2 and Zone 2 Locations |
CSA PLUS 2203 : 2001 | HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES |
CSA C22.3 No. 61936-1 : 2008 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CSA C22.3 No. 61936-1 : 2008 : R2015 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
IEC TR 60079-20:1996 | Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
ISO 965-2:1998 | ISO general purpose metric screw threads — Tolerances — Part 2: Limits of sizes for general purpose external and internal screw threads — Medium quality |
ISO 4017:2014 | Fasteners Hexagon head screws Product grades A and B |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
ISO 4032:2012 | Hexagon regular nuts (style 1) — Product grades A and B |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
ISO 4762:2004 | Hexagon socket head cap screws |
ISO 262:1998 | ISO general purpose metric screw threads — Selected sizes for screws, bolts and nuts |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-3:1990 | Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits |
ISO 4027:2003 | Hexagon socket set screws with cone point |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
ISO 4029:2003 | Hexagon socket set screws with cup point |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
ISO 4026:2003 | Hexagon socket set screws with flat point |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
ISO 273:1979 | Fasteners — Clearance holes for bolts and screws |
ISO 965-1:2013 | ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data |
ISO 179:1993 | Plastics Determination of Charpy impact strength |
ISO 4028:2003 | Hexagon socket set screws with dog point |
ISO 48:2010 | Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
ISO 178:2010 | Plastics Determination of flexural properties |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
ISO 1817:2015 | Rubber, vulcanized or thermoplastic Determination of the effect of liquids |
ISO 4014:2011 | Hexagon head bolts Product grades A and B |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.