• Shopping Cart
    There are no items in your cart

DIN EN 50014 : 2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS

Superseded date

01-12-2004

Superseded by

DIN EN 60079-0 : 2014

Published date

12-01-2013

Sorry this product is not available in your region.

Vorwort
ALLGEMEINES
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen und Symbole
ANFORDERUNGEN FÜR ALLE ELEKTRISCHEN BETRIEBSMITTEL
4 Einteilung der elektrischen Betriebsmittel in
   Gruppen und Temperaturklassen
5 Temperaturen
6 Allgemeines
7 Nichtmetallische Gehäuse und nichtmetallische
   Gehäuseteile
8 Gehäuse aus Leichtmetall
9 Verschlüsse
10 Verriegelungen
11 Durchführungen
12 Werkstoffe zum Verkleben
13 Ex-Bauteile
14 Anschlussteile und Anschlussräume
15 Anschlussteile für Schutzleiter oder
   Potentialausgleichsleiter
16 Einführungen für Kabel, Leitungen und Rohrleitungen
ERGÄNZENDE ANFORDERUNGEN FÜR BESTIMMTE
ELEKTRISCHE BETRIEBSMITTEL
17 Drehende elektrische Maschinen
18 Schaltgeräte
19 Sicherungen
20 Steckvorrichtungen und Steckverbinder
21 Leuchten
22 Kopfleuchten, Handleuchten und Batterien
PRÜFUNGEN
23 Typprüfungen
24 Stückprüfungen
25 Verantwortlichkeit des Herstellers
26 Prüfungen elektrischer Betriebsmittel nach Änderung
   oder Instandsetzung
KENNZEICHNUNG
27 Kennzeichnung
BETRIEBSANLEITUNG
28 Betriebsanleitung
Anhang A (informativ) Unterteilung der Gase und Dämpfe
         nach ihrer Grenzspaltweite und nach ihrem
         Mindestzündstrom
Anhang B (normativ) Ex-Kabel- und Leitungseinführungen
         (KLE)
Anhang C (normativ) Abschnitte, denen Ex-Bauteile
         entsprechen müssen
Anhang D (informativ) Beispiel einer Vorrichtung für die
         mechanische Stossprüfung
Anhang E (gestrichen durch Änderung 1)

Specifies the general requirements for construction, marking and testing of: electrical apparatus, Ex components and Ex cable entries. Coverage includes: definitions and symbols; apparatus grouping and temperature classification; temperatures. Also includes annexes.

DocumentType
Standard
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

VDE 0101 : 2000 POWER INSTALLATIONS EXCEEDING 1 KV
DIN 33962:1997-03 MEASUREMENT OF GASEOUS EMISSIONS; AUTOMATIC MEASUREMENT SYSTEMS FOR SINGLE MEASUREMENTS OF NITROGEN MONOXIDE AND NITROGEN DIOXIDE
DIN 57166 : 1981 ELECTRICAL INSTALLATIONS AND EQUIPMENT FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL
DIN EN 50015 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - OIL IMMERSION 'O'
BWB TL 6230-0074 : 2ED 2003 SPOTLIGHT, PORTABLE, FLASH AND LONG-DISTANCE, EXPLOSION-PROOF
VDE 0400-40-1 : 2000 AMD 1 2004 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
VDE 0400-6 : 2000 GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES
VDE 0170/0171-3 : 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - PRESSURIZED APPARATUS "P"
DIN VDE 0170/0171-14 : 1992 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES; CAP LIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP
VDE 0165-10 : 1999 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
BWB TL 4440-0002 : 5ED 1998 AIR DRIER, ROOM, ELECTRIC, EXPLOSION PROOF, FOR ROOMS UP TO 250 CBM
DIN 40012-1:1984-05 PROTECTION AGAINST EXPLOSION - MARKING OF ELECTRICAL EQUIPMENT - SIGNS AND PLATES
VDE 0170/0171-14 : 1992 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP
DIN EN 61779-1 : 2001 AMD 11 2004 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
DIN EN 50073 : 2000 GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES OR OXYGEN
BWB TL 6230-0050 : 3ED 1989 FLASHLIGHT, EXPLOSION-PROOF, 24 V, 25 W
DIN 42673-2:1983-04 TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE TYPE IM B 3, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATINGS FOR TYPE OF PROTECTION INCREASED SAFETY "E"
DIN V ENV 50269 : 1998 ASSESSMENT AND REPRESENTATIVE TESTING OF HIGH-VOLTAGE MACHINES
DIN 8960:1998-11 REFRIGERANTS - REQUIREMENTS AND SYMBOLS
VDI/VDE 2189 Blatt 3:1994-10 Three-level stepping controllers - Methods of evaluation the performance
VDI/VDE 2189 Blatt 4:1997-09 Digital acting compact controllers - Methods of evaluating the performance
VDI/VDE 3546 Blatt 1:1987-08 Design of process control rooms; general considerations
VDI/VDE 2184:2008-06 Reliable operation and maintenance of field bus systems
VDI/VDE 3515:2007-12 Multi-contact plug system for electrodes used in process analysis technology
VDE 0804 : 1989 AMD 1 1992 TELECOMMUNICATIONS; ADDITIONAL REQUIREMENTS FOR CONSTRUCTION AND TESTING OF APPARATUS
VDE 0170-15-1-1 : 1999 AMD 1 2002 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1-1: CONSTRUCTION AND TESTING
VDE 0620 : 1992 PLUGS AND SOCKET-OUTLETS UP TO 400 V, 25 A
DIN EN 50241-1 : 2000 AMD 1 2004 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
DIN VDE 0848-5 : 2001 SAFETY IN ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS - PROTECTION AGAINST EXPLOSION
DIN 57606-1 : 1984 CONNECTING MATERIAL UP TO 660 V; INSTALLATION BOXES FOR ACCOMMODATION OF EQUIPMENT AND/OR CONNECTING TERMINALS
VDE 0170-12-2 : 2001-05 GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST
DIN EN 50303 : 2001-05 GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST
VDE 0118-1 : 2010 ERRICHTEN ELEKTRISCHER ANLAGEN IM BERGBAU UNTER TAGE - TEIL 1: ALLGEMEINE FESTLEGUNGEN
VDE 0166 : 81 AMD 1 87 ELECTRICAL INSTALLATIONS AND APPARATUS THEREOF FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL
DIN VDE 0891-5 : 1985 USE OF CABLES AND INSULATED WIRES FOR TELECOMMUNICATION SYSTEMS AND DATA PROCESSING SYSTEMS - SPECIAL DIRECTION FOR WIRING CABLES ACCORDING TO DIN VDE 0815
VDE 0118 SUPP 1 : 1998 ERECTION OF ELECTRICAL INSTALLATIONS IN MINES - GUIDE FOR THE PREPARATION OF A TECHNICAL DOCUMENTATION IN THE SENSE OF THE MACHINE DIRECTIVE
DIN VDE 0620 : 1992 PLUGS AND SOCKET-OUTLETS UP TO 400 V 25 A
DIN VDE 0606-1 : 2000 CONNECTING MATERIALS UP TO 690 V - PART 1: INSTALLATION BOXES FOR ACCOMMODATION OF EQUIPMENT AND/OR CONNECTING TERMINALS
DIN 42677-2:1983-04 TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE, TYPE IM B 5, IM B 10, IM B 14, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATINGS FOR TYPE OF PROTECTION INCREASED SAFETY "E"
DIN 42673-3:1983-04 TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE, TYPE IM B 3, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATING FOR TYPE OF PROTECTION FLAMEPROOF ENCLOSURE "D"
VDE 0891-5 : 1985 USE OF CABLES AND INSULATED WIRES FOR TELECOMMUNICATION SYSTEMS AND DATA PROCESSING SYSTEMS; SPECIAL DIRECTION FOR WIRING CABLES
DIN 42677-3:1983-04 TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE, TYPE IM B 5, IM B 10, IM B 14, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATINGS FOR TYPE OF PROTECTION FLAMEPROOF ENCLOSURE "D"
DIN EN 50284 : 2000 SPECIAL REQUIREMENTS FOR CONSTRUCTION, TEST AND MARKING OF ELECTRICAL APPARATUS OF EQUIPMENT GROUP II, CATEGORY 1 G
DIN EN 50021 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - TYPE OF PROTECTION "N"
VDE 0848-5 : 2001 SAFETY IN ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS - PART 3: PROTECTION AGAINST EXPLOSION
DIN EN 50017 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - POWDER FILLING 'Q'
VDE V 0170/0171-60 : 1998 ASSESSMENT AND REPRESENTATION TESTING OF HIGH-VOLTAGE MACHINES
DIN EN 50018 : 2001 AMD 1 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"

DIN 53519-1:1972-05 TESTING OF ELASTOMERS; DETERMINATION OF INDENTATION HARDNESS OF SOFT RUBBER (IRHD); HARDNESS TESTING ON STANDARD SPECIMENS
EN 50033 : 1991 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP
ISO 4892-1:2016 Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance
IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
DIN IEC 60216-2 : 1996 GUIDE FOR THE DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - PART 2: CHOICE OF TEST CRITERIA
EN 60192:2001 Low pressure sodium vapour lamps - Performance specifications
EN 50281-1-1 : 98 AMD 1 2002 ELECTRICAL APPARATUS PROTECTED BY ENCLOSURES - CONSTRUCTION AND TESTING FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - ELECTRICAL APPARATUS PROTECTED BY ENCLOSURES - CONSTRUCTION AND TESTING
VDE 0530-5 : 2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE); CLASSIFICATION
EN 50039:1980 Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i'
DIN 17660:1983-12 WROUGHT COPPER ALLOYS - COPPER-ZINC ALLOYS - (BRASS) - (SPECIAL BRASS) - COMPOSITION
DIN EN 50017 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - POWDER FILLING 'Q'
VDE 0170-15-1 : 2014 EXPLOSIVE ATMOSPHERES - PART 31: EQUIPMENT DUST IGNITION PROTECTION BY ENCLOSURE 'T' (IEC 60079-31:2013)
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
DIN EN 24017:1992-02 HEXAGON HEAD SCREWS - PRODUCT GRADES A AND B
VDE 0304-22 : 2006 Electrical insulating materials - Thermal endurance properties Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria (IEC 60216-2:2005); German version EN 60216-2:2005
DIN EN 24014:1992-02 HEXAGON HEAD BOLTS - PRODUCT GRADES A AND B
ISO 426-2:1983 Wrought copper-zinc alloys — Chemical composition and forms of wrought products — Part 2: Leaded copper-zinc alloys
DIN 13-13:1983-10 ISO METRIC SCREW THREADS - SELECTED SIZES FOR SCREWS, BOLTS AND NUTS FROM 1 TO 52 MM SCREW THREAD DIAMETER AND LIMITS OF SIZES
ISO 965-2:1998 ISO general purpose metric screw threads — Tolerances — Part 2: Limits of sizes for general purpose external and internal screw threads — Medium quality
IEC 60050-486:1991 International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries
ISO 4017:2014 Fasteners Hexagon head screws Product grades A and B
VDE 0170/0171-14 : 1992 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP
EN 50017:1998 Electrical apparatus for potentially explosive atmospheres - Powder filling "q"
EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
VDE 0170-6 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
ISO 4032:2012 Hexagon regular nuts (style 1) — Product grades A and B
EN 50018 : 2000 AMD 1 2002 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"
HD 611.1 : 200S1 GUIDE FOR THE DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - GENERAL GUIDELINES FOR AGEING PROCEDURES AND EVALUATION OF TEST RESULTS
DIN IEC 60216-1 : 1996 GUIDE FOR THE DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - PART 1: GENERAL GUIDELINES FOR AGEING PROCEDURES AND EVALUATING OF TEST RESULTS
VDE 0170-5 : 2015-04 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' (IEC 60079-1:2014)
ISO 4762:2004 Hexagon socket head cap screws
ISO 262:1998 ISO general purpose metric screw threads — Selected sizes for screws, bolts and nuts
DIN EN 50019 : 2001 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
DIN VDE 0170/0171-9 : 1988 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES; ENCAPSULATION "M"
ISO 4027:2003 Hexagon socket set screws with cone point
DIN 13-15:1982-08 ISO METRIC SCREW THREADS - FUNDAMENTAL DEVIATIONS AND TOLERANCES FOR SCREW THREADS FROM 1 MM NOMINAL DIAMETER AND LARGER
VDE 0170-7 : 2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I" (IEC 60079-11:2011 + COR.:2012)
VDE 0170/0171-10 : 1982 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSICALLY SAFE ELECTRICAL SYSTEMS "I"
VDE 0170/0171-3 : 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - PRESSURIZED APPARATUS "P"
DIN VDE 0170/0171-14 : 1992 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES; CAP LIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP
DIN EN 60423:2008-07 CONDUIT SYSTEMS FOR CABLE MANAGEMENT - OUTSIDE DIAMETERS OF CONDUITS FOR ELECTRICAL INSTALLATIONS AND THREADS FOR CONDUITS AND FITTINGS
ISO 4029:2003 Hexagon socket set screws with cup point
DIN EN 50281-1-1 : 1999 AMD 1 2002 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1-1: ELECTRICAL APPARATUS PROTECTED BY ENCLOSURES - CONSTRUCTION AND TESTING
DIN 13-14:1982-08 ISO METRIC SCREW THREADS - BASIS OF THE TOLERANCE SYSTEM FOR SCREW THREADS 1 MM NOMINAL DIAMETER AND LARGER
VDE 0170-4 : 2015 Rotating electrical machines Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets
DIN EN 60192:2002-03 LOW-PRESSURE SODIUM VAPOUR LAMPS - PERFORMANCE SPECIFICATIONS
ISO 4026:2003 Hexagon socket set screws with flat point
DIN EN 60662:2013-03 HIGH-PRESSURE SODIUM VAPOUR LAMPS - PERFORMANCE SPECIFICATIONS
ISO 286-2:2010 Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
VDE 0170-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 6: EQUIPMENT PROTECTION BY LIQUID IMMERSION 'O' (IEC 60079-6:2015)
DIN VDE 0530-5 : 1988 ROTATING ELECTRICAL MACHINES - PART 5: CLASSIFICATION OF DEGREES OF PROTECTION PROVIDED BY ENCLOSURES FOR ROTATING MACHINERY
ISO 965-1:2013 ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data
DIN EN 24032:1992-02 HEXAGON NUTS, STYLE 1 - PRODUCT GRADES A AND B
DIN EN 50020 : 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSIC SAFETY 'I'
DIN 53519-2:1972-05 TESTING OF ELASTOMERS; DETERMINATION OF INDENTATION HARDNESS OF SOFT RUBBER (IRHD); HARDNESS TESTING ON SPECIMENS OF SMALL DIMENSIONS, MICRO-TESTING
ISO 179:1993 Plastics Determination of Charpy impact strength
DIN EN 50015 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - OIL IMMERSION 'O'
EN 50015:1998 Electrical apparatus for potentially explosive atmospheres - Oil immersion "o"
ISO 4028:2003 Hexagon socket set screws with dog point
EN 60662:2012 High-pressure sodium vapour lamps - Performance specifications
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50016:2002 Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p"
ISO 48:2010 Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD)
VDE 0304-21 : 2014 ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 1: AGEING PROCEDURES AND EVALUATION OF TEST RESULTS
EN 50028:1987 Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm'
VDE 0170-9 : 2015 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' (IEC 60079-18:2014)
HD 611.2 : 200S1 GUIDE FOR THE DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
ISO 178:2010 Plastics Determination of flexural properties
VDE 0715-3 : 1996 LOW PRESSURE SODIUM VAPOUR LAMPS
DIN EN 50018 : 2001 AMD 1 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"
EN 60034-5:2001/A1:2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION
ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids
ISO 4014:2011 Hexagon head bolts Product grades A and B
EN 60423:2007 Conduit systems for cable management - Outside diameters of conduits for electrical installations and threads for conduits and fittings

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.