BS EN 60079-15:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Explosive atmospheres Equipment protection by type of protection \'n\'
Hardcopy , PDF
11-05-2019
English
30-11-2016
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Temperatures
6 Requirements for electrical equipment
7 Connection facilities and terminal compartments
8 Supplementary requirements for non-sparking
electrical machines
9 Supplementary requirements for non-sparking fuses
and fuse assemblies
10 Supplementary requirements for non-sparking plugs
and sockets
11 Supplementary requirements for non-sparking luminaires
12 Supplementary requirements for equipment incorporating
non-sparking cells and batteries
13 Supplementary requirements for non-sparking low power
equipment
14 Supplementary requirements for non-sparking current
transformers
15 Other non-sparking electrical equipment
16 General supplementary requirements for equipment producing
arcs, sparks or hot surfaces
17 Supplementary requirements for enclosed-break devices
and non-incendive components producing arcs, sparks or
hot surfaces
18 Supplementary requirements for hermetically sealed
devices producing arcs, sparks or hot surfaces
19 Supplementary requirements for sealed devices producing
arcs, sparks or hot surfaces
20 Supplementary requirements for restricted-breathing
enclosures protecting equipment producing arcs, sparks
or hot surfaces
21 General information on verification and tests
22 Type tests
23 Routine verifications and tests
24 Marking
25 Documentation
26 Instructions
Annex A (informative) - Application, installation, and testing
considerations for Ex 'nA' asynchronous machines
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZY (informative) - Significant changes between this
European Standard and EN 60079-15:2005
Annex ZZ (informative) - Coverage of essential requirements
of the directive 94/9/EC
National Annex NA (informative) - IEC 60079-15
Edition 4.0 2010-01
Defines requirements for the construction, testing and marking for Group II electrical equipment with type of protection, 'n' intended for use in explosive gas atmospheres.
Committee |
EXL/31
|
DevelopmentNote |
To be read in conjunction with BS EN 60079-0. Supersedes 96/214727 DC (10/2003) Supersedes DD ENV 50269. (04/2005) Supersedes BS 6941(1988). (11/2005) 2003 version has been declared inactive for the new design. Supersedes BS EN 50021. (05/2008) Supersedes 07/30168628 DC & 08/30186575 DC. (09/2010)
|
DocumentType |
Standard
|
ISBN |
9780580962271
|
Pages |
84
|
ProductNote |
Implementation of IEC Interpretation Sheet 1 September 2016 in National Annex NA(30-11-2016)
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC60079 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection, \'n\' intended for use in explosive gas atmospheres. This standard applies to electrical equipment where the rated voltage does not exceed 15kV r.m.s. a.c. or d.c. This part of IEC60079 is applicable to non-sparking electrical equipment and also to electrical equipment with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive gas atmosphere. This standard describes several different methods by which this can be achieved which may be combined with other methods described in IEC60079‑0 . This standard supplements and modifies the general requirements of IEC60079‑0 , except as indicated in Table1. Where a requirement of this standard conflicts with a requirement of IEC60079‑0 , the requirement of this standard takes precedence. Table1 Relationship of this part to IEC60079-0 Clause of IEC60079‑0 IEC60079‑0 clause application to IEC60079‑15 Ed. 5.0 (2007) (informative) Ed. 6.0 1 (future edition) (informative) Clause / Subclause title (normative) Protected spar king Non sparking Restricted breathing nC nA nR 4 4 Equipment grouping Applies Applies Applies 4.1 4.1 Group I Excluded Excluded Excluded 4.2 4.2 Group II Applies Applies Applies 4.3 4.3 Group III Excluded Excluded Excluded 4.4 4.4 Equipment for a particular explosive atmosphere Applies Applies Applies 5.1 5.1 Environmental influences Applies Applies Applies 5.1.1 5.1.1 Ambient temperature Applies Applies Applies 5.1.2 5.1.2 External source of heating or cooling Applies Applies Applies 5.2 5.2 Service temperature Applies Applies Applies 5.3.1 5.3.1 Determination of maximum surface temperature Applies Applies Applies 5.3.2.1 5.3.2.1 Group I electrical equipment Excluded Excluded Excluded 5.3.2.2 5.3.2.2 Group II electrical equipment Applies Applies Applies 5.3.2.3 5.3.2.3 Group III electrical equipment Excluded Excluded Excluded 5.3.3 5.3.3 Small component temperature for Group I and Group II electrical equipment Applies Applies Excluded 6.1 6.1 General Applies Applies Applies 6.2 6.2 Mechanical strength Applies Applies Applies 6.3 6.3 Opening times Excluded Excluded Applies 6.4 6.4 Circulating currents Applies Applies Applies 6.5 6.5 Gasket retention Applies Applies Applies 6.6 6.6 Electromagnetic and ultrasonic radiating equipment Applies Applies Applies 7.1.1 7.1.1 Applicability Applies Applies Applies 7.1.2 7.1.2 Specification of materials Applies Applies Applies 7.1.3 7.1.2.2 Plastic materials Applies Applies Applies 7.1.4 7.1.2.3 Elastomeric materials Applies Applies Applies 7.2 7.2 Thermal endurance Applies Applies Applies 7.3 7.3 Resistance to light Applies Applies Applies 7.4 7.4 Electrostatic charges on external non-metallic materials Applies Applies Applies 7.5 9.1 Threaded holes Applies Applies Applies 8.1.1 8.2 Group I Excluded Excluded Excluded 8.1.2 8.3 Group II Applies Applies Applies 8.1.3 8.4 Group III Excluded Excluded Excluded 8.2 9.1 Threaded holes Applies Applies Applies 9.1 9.1 General Applies Applies Applies 9.2 9.2 Special fasteners Excluded Excluded Excluded 9.3 9.3 Holes for special fasteners Excluded Excluded Excluded 10 10 Interlocking devices Excluded Excluded Excluded 11 11 Bushings Applies Applies Applies 12 12 Materials used for cementing Modified Modified Modified 13 13 Ex components Applies Applies Applies 14 14 Connection facilities and termination compartments Modified Modified Modified 15 15 Connection facilities for earthing and bonding conductors Applies Applies Applies 16 16 Entries into enclosures Applies Applies Applies 17 17 Supplementary requirements for rotating electrical machines Excluded Modified Excluded 18 18 Supplementary requirements for switchgear Applies Applies Applies 19 19 Supplementary requirements for fuses Modified Modified Modified 20 20 Supplementary requirements for plugs and sockets Modified Modified Modified 21 21 Supplementary requirements for luminaires Modified Modified Modified 22 22 Supplementary requirements for caplights and handlights Applies Applies Applies 23 23 Equipment incorporating cells and batteries Modified Modified Modified 24 24 Documentation Applies Applies Applies 25 25 Compliance of prototype or sample with documents Applies Applies Applies 26.1 26.1 General Applies Applies Applies 26.2 26.2 Test configuration Applies Applies Applies 26.3 26.3 Tests in explosive test mixtures Applies Applies Applies 26.4 26.4 Tests of enclosures Applies Applies Applies 26.4.1.1 26.4.1.1 Metallic enclosures, metallic parts of enclosures and glass parts of enclosures Applies Applies Applies 26.4.1.2.1 26.4.1.2.1 Group I electrical equipment Excluded Excluded Excluded 26.4.1.2.2 26.4.1.2.2 Group II and Group III electrical equipment Applies Applies Applies 26.4.2 26.4.2 Resistance to impact Applies Applies Applies 26.4.3 26.4.3 Drop test Applies Applies Applies 26.4.4 26.4.4 Acceptance criteria Applies Applies Applies 26.4.5 26.4.5 Degree of protection by enclosure Applies Applies Applies 26.5 26.5 Thermal tests Applies Applies Applies 26.6 26.6 Torque test for bushings Applies Applies Applies 26.7 26.7 Non-metallic enclosures or non-metallic parts of enclosures Modified Modified Modified 26.8 26.8 Thermal endurance to heat Modified Modified Modified 26.9 26.9 Thermal endurance to cold Applies Applies Applies 26.10 26.10 Resistance to light Applies Applies Applies 26.11 26.11 Resistance to chemical agents for Group I electrical equipment Excluded Excluded Excluded 26.12 26.12 Earth continuity Applies Applies Applies 26.13 26.13 Surface resistance test of parts of enclosures of non-metallic materials Applies Applies Applies 26.14 - Charging tests Applies Applies Applies 26.15 26.14 Measurement of capacitance Applies Applies Applies 27 27 Routine tests Applies Applies Applies 28 28 Manufacturers responsibility Applies Applies Applies 29 29 Marking Applies Applies Applies 30 30 Instructions Applies Applies Applies AnnexA AnnexA Supplementary requirements for Ex cable glands Applies Applies Applies AnnexB AnnexB Requirements for Ex components Applies Applies Applies AnnexC AnnexC Example of rig for resistance to impact test Applies Applies Applies AnnexD AnnexD Introduction to an alternative risk assessment method encompassing “equipment protection levels” fro Ex equipment Applies Applies Applies Applies : this requirement of IEC60079‑0 is applied without change. Excluded : this requirement of IEC60079‑0 does not apply. Modified : this requirement of IEC60079‑0 is modified as detailed in this standard. NOTE1 The clause number in the above table is shown for information only. The applicable requirements of IEC60079‑0 are identified by the clause title which is normative. This document was written against the specific requirements of IEC60079‑0 (ed. 5.0). The clause numbers for the previous edition are shown for information only. This is to enable the General Requirements IEC60079‑0 (ed. 5.0) to be used where necessary with this part of IEC60079 . Where there were no requirements, indicated by “NR” or there is a conflict between requirements, the later edition requirements take precedence. NOTE2 A non-incendive component is limited in use to the particular circuit for which it has been shown to be non-ignition capable and, therefore, cannot be separately assessed as complying with this standard. NOTE3 Compliance with this standard does not imply any removal of, or lowering of the requirements of any other standard with which the electrical equipment complies. NOTE4 This part of IEC60079 supplements, and may enhance, the requirements for equipment for normal industrial applications. Where compliance with other IEC standards is indicated, such as IEC60034 for motors and IEC60598‑2 for luminaires, proving compliance to those standards is normally the responsibility of the manufacturer. NOTE5 Type of protection “n” provides Equipment Protection Level (EPL) Gc. For further information, see IEC60079‑0 .
Standards | Relationship |
SN EN 60079-15 : 2005 | Identical |
I.S. EN 60079-15:2010 | Identical |
NF EN 60079-15 : 2010 | Identical |
EN 60079-15:2010 | Identical |
UNE-EN 60079-15:2013 | Identical |
DIN EN 60079-15 : 2011 | Identical |
IEC 60079-15:2010 | Identical |
NBN EN 60079-15 : 2010 | Identical |
IEC 60079-15:2010/ISH1:2016 | Identical |
17/30351608 DC : 0 | BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: INSTALLATIONS PROVIDING SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES TO NON-DOMESTIC BUILDINGS |
12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
12/30170835 DC : 0 | BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES FOR COMMERCIAL AND INDUSTRIAL PREMISES |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
BS 5410-2:2013 | Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included) |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60947-7-2:2009 | Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors |
IEC 60228:2004 | Conductors of insulated cables |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
EN 60238 : 2004 AMD 2 2011 | EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011) |
EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
IEC 60998-2-4:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-4: Particular requirements for twist-on connecting devices |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60050-411:1996 | International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
EN 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
EN 61347-2-4:2001/corrigendum:2010 | LAMP CONTROLGEAR - PART 2-4: PARTICULAR REQUIREMENTS FOR D.C. SUPPLIED ELECTRONIC BALLASTS FOR GENERAL LIGHTING |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
IEC TS 60034-18-41:2006 | Rotating electrical machines - Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
EN 60998-2-4:2005 | Connecting devices for low voltage circuits for household and similar purposes - Part 2-4: Particular requirements for twist-on connecting devices |
IEC 61347-2-4:2000 | Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 61347-2-3:2011/A1:2017 | LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS (IEC 61347-2-3:2011/A1:2016) |
EN 60927:2007/A1:2013 | AUXILIARIES FOR LAMPS - STARTING DEVICES (OTHER THAN GLOW STARTERS) - PERFORMANCE REQUIREMENTS (IEC 60927:2007/A1:2013 (34C/951/CDV)) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 61347-2-7:2012 | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC TS 60034-25:2014 | Rotating electrical machines - Part 25: AC electrical machines used in power drive systems - Application guide |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC TS 60034-17:2006 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
IEC 60079-29-2:2015 RLV | Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
CLC/TS 60034-25:2008 | Rotating electrical machines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
EN 61184:2017 | Bayonet lampholders |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
EN 60947-7-1:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
HD 60269-3:2010/A1:2013 | LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
IEC 61184:2017 | Bayonet lampholders |
EN 61195:1999/A2:2015 | DOUBLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61195:1999/A2:2014) |
EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
EN 60947-7-2:2009 | Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.