I.S. EN 60539-1:2016
Current
The latest, up-to-date edition.
DIRECTLY HEATED NEGATIVE TEMPERATURE COEFFICIENT THERMISTORS - PART 1: GENERIC SPECIFICATION
Hardcopy , PDF
English
01-01-2016
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General items
5 Test and measurement procedures
Annex A (normative) - Interpretation of sampling plans
and procedures as described in IEC 60410:1973
for use within quality assessment systems
Annex B (normative) - Rules for the preparation of detail
specifications for directly heated thermistors for
electronic equipment for use within quality
assessment systems
Annex C (informative) - Typical examples of mountings for
measurements of directly heated thermistors
Annex D (informative) - Reference to IEC 60539-1:2008
Annex Q (normative) - Quality assessment procedures
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Defines standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. Pertains to directly heated negative temperature coefficient thermistors, typically made from transition metal oxide materials with semiconducting properties.
DevelopmentNote |
Supersedes I.S. EN 143000. (08/2016) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
130
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60539-1 : 2016 | Identical |
DIN EN 60539-1:2013-10 (Draft) | Identical |
BS EN 60539-1:2008 | Identical |
EN 60539-1:2016/AC:2017-09 | Identical |
NBN EN 60539-1 : 2008 | Identical |
BS EN 60539-1:2016 | Identical |
IEC 61193-2:2007 | Quality assessment systems - Part 2: Selection and use of sampling plans for inspection of electronic components and packages |
EN 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN ISO 80000-1:2013 | Quantities and units - Part 1: General (ISO 80000-1:2009 + Cor 1:2011) |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-58:2015+AMD1:2017 CSV | Environmental testing - Part 2-58: Tests - Test Td: Test methods for solderability, resistance to dissolution of metallization and to soldering heat of surface mounting devices (SMD) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 61249-2-7:2002 | Materials for printed boards and other interconnecting structures - Part 2-7: Reinforced base materials clad and unclad - Epoxide woven E-glass laminated sheet of defined flammability (vertical burning test), copper-clad |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
EN 60027-1:2006/A2:2007 | LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY - PART 1: GENERAL |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
EN 61249-2-7:2002/corrigendum:2005 | MATERIALS FOR PRINTED BOARDS AND OTHER INTERCONNECTING STRUCTURES - PART 2-7: REINFORCED BASE MATERIALS CLAD AND UNCLAD - EPOXIDE WOVEN E-GLASS LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST), COPPER-CLAD |
EN 60717:2012 | Method for the determination of the space required by capacitors and resistors with unidirectional terminations |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
IEC 60068-2-54:2006 | Environmental testing - Part 2-54: Tests - Test Ta: Solderability testing of electronic components by the wetting balance method |
EN 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
EN 61193-2 : 2007 | QUALITY ASSESSMENT SYSTEMS - PART 2: SELECTION AND USE OF SAMPLING PLANS FOR INSPECTION OF ELECTRONIC COMPONENTS AND PACKAGES |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
ISO 80000-1:2009 | Quantities and units — Part 1: General |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60717:2012 | Method for the determination of the space required by capacitors and resistors with unidirectional terminations |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
EN 60068-2-54:2006 | Environmental testing - Part 2-54: Tests - Test Ta: Solderability testing of electronic components by the wetting balance method |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 60068-2-69:2017 | Environmental testing - Part 2-69: Tests - Test Te/Tc: Solderability testing of electronic components and printed boards by the wetting balance (force measurement) method |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |