Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
21-06-2019
English - French
29-01-2013
FOREWORD
1 General scope
Fuse system A - D type fuse system
1 General
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
6 Markings
7 Standard conditions for construction
8 Tests
Annex AA (informative) - Special test for cable overload
protection (for fuse system A)
Fuse system B - Cylindrical fuses (NF cylindrical
fuse system)
1 General
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
6 Markings
7 Standard conditions for construction
8 Tests
Fuse system C - Cylindrical fuses (BS cylindrical
fuse system)
1 General
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
6 Markings
7 Standard conditions for construction
8 Tests
Fuse system F - Cylindrical fuse-links for use in
plugs (BS plugtop system)
1 General
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
6 Markings
7 Standard conditions for construction
8 Tests
Annex BB (informative) - (for all fuse systems) - Alternative
tests for tests No. 1 and No. 2 of
Table 20 of IEC 60269-1
Annex CC (informative) - Recommendations for future designs
of fuses (for all fuse systems)
Bibliography
IEC 60269-3:2010+A1:2013 provides supplementary requirements for fuses for use by unskilled persons according to the following fuse systems comply with all subclauses of IEC 60269-1 and with the requirements laid down in the relevant fuse systems. This Part 3 supplements or modifies the corresponding clauses or subclauses of Part 1.
This publication is to be read in conjunction with IEC 60269-1:2009. This consolidated version consists of the fourth edition (2010), its amendment 1 (2013) and its corrigendum 1 (2013). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 32/SC 32B
|
DevelopmentNote |
Supersedes IEC 60088 (03/2001) Supersedes IEC 60269-3-1. To be used in conjunction with IEC 60269-1. (12/2006) Also available on CR-ROM format. (01/2013) Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
317
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
CEI 32-13 V1 : 2014 | Identical |
DIN VDE 0636-3 : 2013 | Identical |
VDE 0636-3 : 2013 | Identical |
NEN EN IEC 60269-3 : 1995 AMD 1 2003 | Identical |
I.S. EN 60269-3:1996 | Identical |
NF EN 60269-3 : 96 AMD 1 2004 | Identical |
NEN 10269-3 : 1995 | Identical |
VDE 0636-108 : DRAFT 86 | Similar to |
SN EN 60269-3 : 1995 AMD 1 2003 | Identical |
EN 60269-3:1995/A1:2003 | Identical |
CEI EN 60269-3 : 1997 AMD 1 2005 | Identical |
DIN EN 60269-3 : 2004 | Identical |
NBN C 90 202 : 1983 | Identical |
VDE 0636-30 : 2004 | Identical |
UNE-EN 60269-3:1996 | Identical |
UNE 21103-3:1991 | Identical |
13/30273419 DC : 0 | BS 6387 - TEST METHOD FOR RESISTANCE TO FIRE OF CABLES REQUIRED TO MAINTAIN CIRCUIT INTEGRITY UNDER FIRE CONDITIONS |
UNE-EN 50200:2016 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
NF EN 60269-4 : 2010 AMD 2 2017 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES |
CSA E79.18 : 1995 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ENCAPSULATION "M" |
14/30318875 DC : 0 | BS EN 60269-4:2012+AMD 2 - LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES |
NF EN 60079-15 : 2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
BS EN 60730-2-4:2007 | Automatic electrical controls for household and similar use Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type |
CEI EN 60269-6 : 2012 | LOW-VOLTAGE FUSES - PART 6: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SOLAR PHOTOVOLTAIC ENERGY SYSTEMS |
IEC 60884-2-5:2017 | Plugs and socket-outlets for household and similar purposes - Part 2-5: Particular requirements for adaptors |
CSA E60079.15 : 2002 : R2011 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS WITH TYPE OF PROTECTION "n" |
I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
I.S. EN 50577:2015 | ELECTRIC CABLES - FIRE RESISTANCE TEST FOR UNPROTECTED ELECTRIC CABLES (P CLASSIFICATION) |
IEC TR 60269-5:2014 | Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses |
I.S. EN 50200:2015 | METHOD OF TEST FOR RESISTANCE TO FIRE OF UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS |
BS 3535-1:1990 | Isolating transformers and safety isolating transformers General requirements |
BS EN 61558-1 : 2005 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
04/30115657 DC : DRAFT JUNE 2004 | IEC 61347-2-13 ED 1 - LAMP CONTROLGEAR - PART 2: PARTICULAR REQUIREMENTS FOR D.C. FOR A.C. SUPPLIED ELECTRONIC CONTROLGEARS FOR LED MODULES |
13/30238229 DC : 0 | BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS |
IEC 61037:1990+AMD1:1996+AMD2:1998 CSV | Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers |
CLC/TR 60269-5:2011 | Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses |
EN 62052-31:2016 | Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
EN 61439-3 : 2012 COR 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: DISTRIBUTION BOARDS INTENDED TO BE OPERATED BY ORDINARY PERSONS (DBO) (IEC 61439-3:2012) |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60331-3:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
EN 60269-4:2009/A2:2016 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES (IEC 60269-4:2009/A2:2016) |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
CEI EN 60730-2-4 : 2008 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2: PARTICULAR REQUIREMENTS FOR THERMAL MOTOR PROTECTORS FOR MOTOR-COMPRESSORS OF HERMETIC AND SEMI-HERMETIC TYPE |
BS EN 61037:1993 | Electricity metering. Tarriff and load control. Particular requirements for electronic ripple control receivers |
09/30195381 DC : 0 | BS EN 60269-6 - LOW-VOLTAGE FUSES - PART 6: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SOLAR PHOTOVOLTAIC ENERGY SYSTEMS |
IEC 60331-3:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
GOST R IEC 60269-3-1 : 2004 | LOW-VOLTAGE FUSES - PART 3-1 - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 5 |
BS 5501-8:1988 | Electrical apparatus for potentially explosive atmospheres Encapsulation \'m\' |
I.S. EN 60432-3:2013 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTENHALOGEN LAMPS (NON-VEHICLE) (IEC 60432-3:2012 (EQV)) |
BS EN 60269-1 : 2007 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
NF EN 61558-1 : 2006 AMD 1 2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
CEI EN 60432-3 : 2013 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTEN-HALOGEN LAMPS (NON-VEHICLE) |
BS EN 60432-3:2013 | Incandescent lamps. Safety specifications Tungsten-halogen lamps (non-vehicle) |
BIS IS/IEC 60079-15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS |
CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
IEC 60884-2-1:2006 | Plugs and socket-outlets for household and similar purposes - Part 2-1: Particular requirements for fused plugs |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 61046:1993 | D.C. or a.c. supplied electronic step-down convertors for filament lamps - General and safety requirements |
DIN EN 61046 : 1995 AMD 1 1997 | D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 61058-1:2016 RLV | Switches for appliances - Part 1: General requirements |
VDE 0419-1 : 94 AMD 2 99 | TIME SWITCHES FOR TARIFF AND LOAD CONTROL |
VDE 0551 : 1995 | ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS |
VDE 0420-1 : 94 AMD 2 99 | ELECTRONIC RIPPLE CONTROL RECEIVERS FOR TARIFF AND LOAD CONTROL |
BS 6387:2013 | Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions |
BS 7401(1990) : 1990 AMD 7673 | SPECIFICATION FOR ELECTRONIC RIPPLE CONTROL RECEIVERS FOR TARIFF AND LOAD CONTROL |
12/30276209 DC : 0 | BS EN 60730-2-22 - AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-22: PARTICULAR REQUIREMENTS THERMAL MOTOR PROTECTORS |
CEI EN 50362 : 2003 | METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS |
DIN EN 60742 : 1995 | ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS |
UNE-EN 50577:2016 | Electric cables - Fire resistance test for unprotected electric cables (P classification) |
BS EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
PD IEC/TR 61912-2:2009 | Low-voltage switchgear and controlgear. Over-current protective devices Selectivity under over-current conditions |
03/312546 DC : DRAFT JULY 2003 | IEC 60884-2-1 ED.2 - PLUGS AND SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 2-1: PARTICULAR REQUIREMENTS FOR POLARISED FUSED PLUGS |
EN 50577:2015 | Electric cables - Fire resistance test for unprotected electric cables (P classification) |
16/30342023 DC : 0 | BS EN 60331-1 - TESTS FOR ELECTRIC CABLES UNDER FIRE CONDITIONS - CIRCUIT INTEGRITY - PART 1: TEST METHOD FOR FIRE WITH SHOCK AT A TEMPERATURE OF AT LEAST 830 DEGREES C FOR CABLES OF RATED VOLTAGE UP TO AND INCLUDING 0,6/1,0 KV AND WITH AN OVERALL DIAMETER EXCEEDING 20 MM |
IEC TR 61912-2:2009 | Low-voltage switchgear and controlgear - Over-current protective devices - Part 2: Selectivity under over-current conditions |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
NF EN 60269-1 : 2007 AMD 2 2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
BS EN 60269-4 : 2009 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES (IEC 60269-4:2009) |
IEC 60331-2:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60730-2-4:2006 | Automatic electrical controls for household and similar use - Part 2-4: Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
IEC 61038:1990+AMD1:1996+AMD2:1998 CSV | Electricity metering - Tariff and load control - Particular requirements for time switches |
IEC 60269-4:2009+AMD1:2012+AMD2:2016 CSV | Low-voltage fuses - Part 4: Supplementary requirements forfuse-links for the protection of semiconductor devices |
UNE-EN 61439-3:2012 | Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
CSA C22.2 No. 61347-2-13 : 2015(R2020) | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
03/103717 DC : 0 | IEC 60730-2-4 - AUTOMATIC CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2: PARTICULAR REQUIREMENTS - SECTION 4: THERMAL MOTOR PROTECTORS FOR MOTOR-COMPRESSORS OR HERMATIC AND SEMI-HERMATIC TYPE |
BS 5924:1980 | Specification for safety requirements for electrical equipment of machines for resistance welding and allied processes |
CSA E60730-2-4 : 2013 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-4: PARTICULAR REQUIREMENTS FOR THERMAL MOTOR PROTECTORS FOR MOTOR-COMPRESSORS OF HERMETIC AND SEMI-HERMETIC TYPE |
GOST R IEC 61048 : 2005 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS |
UNE-EN 60269-4:2011 | Low-voltage fuses -- Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices |
I.S. EN 60269-6:2011 | LOW-VOLTAGE FUSES - PART 6: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SOLAR PHOTOVOLTAIC ENERGY SYSTEMS |
I.S. EN 60269-4:2009 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES |
I.S. HD 60364-5-534:2008 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST OVERVOLTAGES |
I.S. EN 60947-7-2:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-2: ANCILLARY EQUIPMENT - PROTECTIVE CONDUCTOR TERMINAL BLOCKS FOR COPPER CONDUCTORS |
I.S. EN 61439-3:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: DISTRIBUTION BOARDS INTENDED TO BE OPERATED BY ORDINARY PERSONS (DBO) (IEC 61439-3:2012 (EQV)) |
GOST R 52350.15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS |
I.S. EN 61558-1:2006 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
S.R. CLC/TR 50480:2011 | DETERMINATION OF CROSS-SECTIONAL AREA OF CONDUCTORS AND SELECTION OF PROTECTIVE DEVICES |
I.S. HD 60364-4-43:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-43: PROTECTION FOR SAFETY - PROTECTION AGAINST OVERCURRENT |
EN 60269-6:2011 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
IEC 62052-31:2015 | Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests |
BS PD88-5(2010) : 2010 | LOW-VOLTAGE FUSES - PART 5: GUIDANCE FOR THE APPLICATION OF LOW-VOLTAGE FUSES |
07/30169755 DC : 0 | BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING |
PD CLC/TR 50480:2011 | Determination of cross-sectional area of conductors and selection of protective devices |
08/30185258 DC : DRAFT JULY 2008 | BS EN 60269-5 - LOW-VOLTAGE FUSES - PART 5: GUIDANCE FOR THE APPLICATION OF LOW-VOLTAGE FUSES |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60730-2-22:2014 | Automatic electrical controls - Part 2-22: Particular requirements for thermal motor protectors |
IEC 61439-3:2012 | Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
15/30328159 DC : 0 | BS EN 61558-1 - SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-HD 60364-4-43:2013 | Low-voltage electrical installations -- Part 4-43: Protection for safety - Protection against overcurrent |
EN 60439-3:1991/corrigendum:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: PARTICULAR REQUIREMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES INTENDED TO BE INSTALLED IN PLACES WHERE UNSKILLED PERSONS HAVE ACCESS FOR THEIR USE - DISTRIBUTION BOARDS |
DIN EN 61038 : 1994 AMD 2 1999 | TIME SWITCHES FOR TARIFF AND LOAD CONTROL |
UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
BS 7314:1990 | Specification for electric stunners for poultry |
NF EN 50362 : 2003 | METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS |
BS EN 50577:2015 | Electric cables. Fire resistance test for unprotected electric cables (P classification) |
DIN VDE 0660-101 : 1992 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT BREAKERS |
DIN EN 61037 : 1994 AMD 2 1999 | ELECTRONIC RIPPLE CONTROL RECEIVERS FOR TARIFF AND LOAD CONTROL |
07/30168628 DC : 0 | BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
BS EN 60439-3 : 1991 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: PARTICULAR REQUIREMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES INTENDED TO BE INSTALLED IN PLACES WHERE UNSKILLED PERSONS HAVE ACCESS FOR THEIR USE - DISTRIBUTION BOARDS |
BS 7415(1991) : 1991 AMD 7674 | SPECIFICATION FOR TIME SWITCHES FOR TARIFF AND LOAD CONTROL |
BS 8491:2008 | Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems |
BS EN 61038:1993 | Specification for time switches for tariff and load control |
05/30135633 DC : DRAFT JUN 2005 | IEC 60269-1 ED 4 - LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
07/30169774 DC : 0 | BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
08/30186575 DC : DRAFT JULY 2008 | BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
BS EN 60269-6:2011 | Low-voltage fuses Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
CSA E60079.15 : 2002 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS WITH TYPE OF PROTECTION "n" |
I.S. EN 60269-1:2007 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62052-31:2016 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS |
UNE-EN 60269-6:2012 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
UNE-EN 60432-3:2013 | Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle) |
CSA C22.2 No. 61347-2-13 : 2015 | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
S.R. CLC/TR 60269-5:2011 | LOW-VOLTAGE FUSES - PART 5: GUIDANCE FOR THE APPLICATION OF LOW-VOLTAGE FUSES |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
I.S. EN 60730-2-4:2007 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-4: PARTICULAR REQUIREMENTS FOR THERMAL MOTOR PROTECTORS FOR MOTOR-COMPRESSORS OF HERMETIC AND SEMI-HERMETIC TYPE |
PD IEC/TR 60269-5:2010 | Low-voltage fuses Guidance for the application of low-voltage fuses |
IEC 60432-3:2012 | Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle) |
IEC 60269-6:2010 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
EN 61046:1994/A1:1996 | D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTERS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
IEC 60331-1:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
EN 61038:1992/A2:1998 | ELECTRICITY METERING - TARIFF AND LOAD CONTROL - PARTICULAR REQUIREMENTS FOR TIME SWITCHES |
EN 60730-2-4:2007 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-4: PARTICULAR REQUIREMENTS FOR THERMAL MOTOR PROTECTORS FOR MOTOR-COMPRESSORS OF HERMETIC AND SEMI-HERMETIC TYPE |
CLC/TR 50480:2011 | Determination of cross-sectional area of conductors and selection of protective devices |
EN 61037:1992/A2:1998 | ELECTRONIC METERING - TARIFF AND LOAD CONTROL - PARTICULAR REQUIREMENTS FOR ELECTRONIC RIPPLE CONTROL RECEIVERS |
EN 60947-7-2:2009 | Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors |
IEC 60331-2:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20mm |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
EN 60432-3:2013 | Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle) |
EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
CSA E730.2.2 : 1994 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2: PARTICULAR REQUIREMENTS FOR THERMAL MOTOR PROTECTORS |
CAN/CSA-E61558-1:12 (R2017) | Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d\'inductance et produits analogues - Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada) |
BS 88-4(2007) : 2007 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES |
CSA C22.2 No. 60079-15 : 2016 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
CSA E61558.1:2012 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
CSA E61558.1 : 2012 : INC : UPD 1 : 2014 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS 88-4(2009) : 2009 + A2 2016 | LOW-VOLTAGE FUSES - PART 4: SUPPLEMENTARY REQUIREMENTS FOR FUSE-LINKS FOR THE PROTECTION OF SEMICONDUCTOR DEVICES (IEC 60269-4:2009) |
BS 88-1(2007) : 2007 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
AS/NZS 5139:2019 | Electrical installations - Safety of battery systems for use with power conversion equipment |
IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
ISO 965-1:2013 | ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data |
ISO 228-2:1987 | Pipe threads where pressure-tight joints are not made on the threads Part 2: Verification by means of limit gauges |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.