ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
Hardcopy , PDF
02-03-2021
English
01-01-2006
1 INTRODUCTION
1.1 Purpose
1.2 Scope
1.3 References
2 CLASSIFIED LOCATIONS OR ELECTRICAL EQUIPMENT
2.1 Purpose
2.2 Scope
2.3 Classification of Flammable and Combustible
Liquids and Gases
2.4 Classification of Locations
2.5 Electrical Equipment for Classified Locations
2.6 Alternative Design in Classified Locations
3 ELECTRICAL ENERGY EFFICIENCY
3.1 Purpose
3.2 Scope
3.3 The Role of Electrical Efficiency
3.4 Definition of Efficiency
3.5 Specification Considerations
3.6 Economic Evaluation
3.7 Cogeneration and Energy Recovery
3.8 Design Considerations
3.9 Relationship to Power Factor
3.10 Definitions and Conversion Factors
4 FACILITY POWER SYSTEMS
4.1 Purpose
4.2 Scope
4.3 Power Sources
4.4 System Voltages
4.5 Power System Arrangements
4.6 Power System Studies
4.7 System Protection
4.8 Fuses
4.9 Circuit Breakers
4.10 Switchgear
4.11 Transformers
4.12 Overhead Electric Power Distribution
5 Grounding and Lightning Protection
5.1 Purpose
5.2 Scope
5.3 Static Electricity and Stray Currents
5.4 System Grounding
5.5 Equipment Grounding
5.6 Connections to Earth
5.7 Lightning Protection
6 MOTORS AND CONTROLLERS
6.1 Purpose
6.2 Scope
6.3 Motor Rating and Efficiency
6.4 Relative Locations of Motors and Controllers
6.5 Frequencies
6.6 Standard Voltage for Motors
6.7 Motor Voltage Selection
6.8 Temperature and Altitude Considerations in
Motor Applications
6.9 Other Conditions Affecting Design and
Application
6.10 Types of Motor Construction
6.11 Installation
6.12 Construction of Totally Enclosed Motors
6.13 Motors for Class I Locations
6.14 Motors for Class II Locations
6.15 Motor Service Factor
6.16 Frequency of Starting
6.17 Temperature, Vibration and Current Indicators
6.18 Conduit or Terminal Box
6.19 Space Heaters
6.20 Bearings and Lubrication
6.21 Torque Requirements
6.22 Method of Starting
6.23 Motor Controllers
6.24 Application of Motor Control
6.25 Means of Disconnection
6.26 Coordination of Controller Applications With
Fuses or Circuit Breakers on Low-Voltage
Systems
6.27 Overload Protection: Special Applications
6.28 Voltage Limitations
6.29 Application of Outdoor and Indoor Types
6.30 Pushbutton Stations
6.31 Additional References
7 LIGHTING
7.1 Purpose
7.2 Scope
7.3 Definition of Terms
7.4 Lighting Facilities
7.5 Luminaires
7.6 Light Quality
7.7 Illuminance
7.8 Installation Initial Values
7.9 Lighting System Power Supply
7.10 Emergency Lighting
7.11 Design Considerations
7.12 Estimating Electric Power Requirements
7.13 Illuminance Meters
8 WIRING
8.1 Purpose
8.2 Scope
8.3 General
8.4 Conduit Systems
8.5 Electrical Metallic Tubing
8.6 Busways
8.7 Wireways
8.8 Cable Trays
8.9 Manholes and Above Grade Pull Points
8.10 Wire and Cable
8.11 Fireproofing
9 POWER SYSTEMS FOR INSTRUMENTATION AND PROCESS
CONTROL
9.1 Purpose
9.2 Scope
9.3 Basic Design Criteria
9.4 Design Considerations
9.5 Electric Power Systems
9.6 Distribution System
9.7 Wiring Methods
9.8 System and Equipment Grounding
9.9 Considerations for Classified Locations
10 SPECIAL EQUIPMENT
10.1 Purpose
10.2 Scope
10.3 General
10.4 Communication Systems
10.5 Supervisory Control and Data Acquisition
Equipment (SCADA)
10.6 Closed-Circuit Television (CCTV)
10.7 Obstruction and Warning Lighting
10.8 Navigation Lighting
10.9 Fire Alarm Systems
10.10 Electric Heat Tracing
10.11 Cathodic Protection Systems
10.12 Desalters and Precipitators
10.13 Portable Equipment
11 INHERENT ELECTRICAL SAFETY
11.1 General
11.2 References
11.3 Specifics
APPENDIX A - (INFORMATIVE) INHERENT SAFETY
CONSIDERATIONS
Provides information on electrical installations in petroleum facilities.
DocumentType |
Revision
|
Pages |
107
|
ProductNote |
Reconfirmed 2006
|
PublisherName |
American Petroleum Institute
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
ISA RP12.1 : 1960 | ELECTRICAL INSTRUMENTS IN HAZARDOUS ATMOSPHERES |
ISA 12.16.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY |
IEEE 519-2014 REDLINE | IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
IEEE 32-1972 | IEEE Standard Requirements, Terminology, and Test Procedures for Neutral Grounding Devices |
NEMA MG 1 : 2016 | MOTORS AND GENERATORS |
NEMA MG 2:2014 | Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators |
IEEE C57.12.01-2015 REDLINE | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
NFPA 110 : 2016 | EMERGENCY AND STANDBY POWER SYSTEMS |
CFR 29(PTS1900-1910) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ANSI C80.5 : 2015 | ELECTRICAL RIGID METAL CONDUIT - ALUMINUM (ERMC-A) |
API 546 : 2008 | BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER |
IEEE 841-2009 | IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp) |
API 614 : 2008 | LUBRICATION, SHAFT-SEALING AND OIL-CONTROL SYSTEMS AND AUXILIARIES |
ISA RP12.24.01 : 1998 | RECOMMENDED PRACTICE FOR CLASSIFICATIONS OF LOCATIONS FOR ELECTRICAL INSTALLATIONS CLASSIFIED AS CLASS I ZONE 0, ZONE 1, OR ZONE 2 |
NEMA ICS 6-1993 (R2006) | Industrial Control and Systems: Enclosures |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
NFPA 69 : 2014 | EXPLOSION PREVENTION SYSTEMS |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
API 2003 : 2015 | PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTNING, AND STRAY CURRENTS |
IEEE 493 : 2007 | DESIGN OF RELIABLE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
NACE RP 01 76 : 2003 | CORROSION CONTROL OF STEEL FIXED OFFSHORE STRUCTURES ASSOCIATED WITH PETROLEUM PRODUCTION |
WC 5-1992 | THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
API 651 : 2014 | CATHODIC PROTECTION OF ABOVEGROUND PETROLEUM STORAGE TANKS |
WC 8:1988 | ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
RR-F-191-4 Revision F:2008 | FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES) |
NACE RP 06 75 : 1988 | CORROSION CONTROL OF OFFSHORE STEEL PIPELINES |
API 552 : 1994 | TRANSMISSION SYSTEMS |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
AGMA 6019 : E | GEARMOTORS USING SPUR, HELICAL, HERRINGBONE, STRAIGHT BEVEL OR SPIRAL BEVEL GEARS |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
ANSI C80.1 : 2015 | ELECTRICAL RIGID STEEL CONDUIT (ERSC) |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
IEEE C57.92-1981 | IEEE Guide for Loading Mineral-Oil-Immersed Power Transformers Up to and Including 100 MVA with 55 C or 65 C Average Winding Rise |
NFPA 70E : 2018 | ELECTRICAL SAFETY IN THE WORKPLACE |
API 505 : 1997 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2 |
IEEE C57.111 : 1989 | GUIDE FOR ACCEPTANCE OF SILICONE INSULATING FLUID AND ITS MAINTENANCE IN TRANSFORMERS |
IEEE 142 : 2007 | GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEEE 1100 : 2005 | POWERING AND GROUNDING ELECTRONIC EQUIPMENT |
NFPA 499 : 2017 | CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
API 2001 : 2012 | FIRE PROTECTION IN REFINERIES |
API 610 : 2010 | CENTRIFUGAL PUMPS FOR PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES |
NEMA ICS 1 : 2000(R2015) | INDUSTRIAL CONTROL AND SYSTEMS: GENERAL REQUIREMENTS |
API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
ISA RP12.13.02 : 2003 | INSTALLATION, OPERATION, AND MAINTENANCE OF COMBUSTIBLE GAS DETECTION INSTRUMENTS |
NFPA 77 : 2014 | STATIC ELECTRICITY |
IEEE 422-2012 | IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities |
NFPA 325M : 1991 | FIRE HAZARD PROPERTIES OF FLAMMABLE LIQUIDS, GASES, AND VOLATILE SOLIDS |
NACE RP 01 69 : 2002 | CONTROL OF EXTERNAL CORROSION ON UNDERGROUND OR SUBMERGED METALLIC PIPING SYSTEMS |
ISA S12.4 : 1970 | INSTRUMENT PURGING FOR REDUCTION OF HAZARDOUS AREA CLASSIFICATION |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
NFPA 37 : 2018 | INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES |
IEEE 515-2011 | IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEEE C57.106-2006 | IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment |
CFR 29(PTS1927-END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
IEEE 844-2000 | IEEE Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and Vessels |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.