FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Additional inspection schedule requirements
6 Inspection tables
Annex A (informative) - Typical inspection procedure
        for periodic inspections
Annex B (normative) - Knowledge, skills and competencies
        of responsible persons, technical persons with
        executive function and operatives
Annex C (informative) - Fitness-for-purpose assessment
Annex D (informative) - Example of motor checks
Bibliography

IEC 60079-17:2013 applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings. It does not include:
- other fundamental installation and inspection requirements for electrical installations;
- the verification of electrical equipment;
- the repair and reclamation of explosion protected equipment (see IEC 60079-19). This standard supplements the requirements of IEC 60364-6. In the case of dusts, fibres or flyings the level of housekeeping may influence the inspection and maintenance requirements. This standard is intended to be applied where there can be a risk due to the presence of explosive gas or dust mixtures with air or combustible dust layers under normal atmospheric conditions. It does not apply to:
- underground mining areas,
- dusts of explosives that do not require atmospheric oxygen for combustion,
- pyrophoric substances. This fifth edition cancels and replaces the fourth edition published in 2007 and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
- Equipment specific inspection tables for luminaires, heating systems and motors have been added into Annex A to supplement the general protection concept tables;
- Document has been updated to complement the changes made to IEC 60079-14 for initial inspection.Keywords: inspection and maintenance of electrical installations within hazardous area, flammable gases, vapours, mists, dusts, fibres or flyings

This publication is to be read in conjunction with IEC 60364-6:2006.

Committee
TC 31/SC 31J
DevelopmentNote
Supersedes IEC 61241-17. (06/2008) To be read in conjunction with IEC 60364-6. Stability date: 2019. (11/2013)
DocumentType
Standard
Pages
75
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

I.S. 821:2006 GAS PRESSURE REGULATING STATIONS FOR DISTRIBUTION
PREN 50050-1 : DRAFT 2011 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 1: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIALS
BS ISO 16924 : 2016 NATURAL GAS FUELLING STATIONS - LNG STATIONS FOR FUELLING VEHICLES
UNE-EN 50050-2:2014 Electrostatic hand-held spraying equipment - Safety requirements - Part 2: Hand-held spraying equipment for ignitable coating powder
11/30248849 DC : 0 BS EN 50050-3:2011 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK
13/30279579 DC : 0 BS ISO 19372 - MICROTURBINES APPLICATIONS - SAFETY
BS EN 15001-2:2008 Gas infrastructure. Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations Detailed functional requirements for commissioning, operation and maintenance
06/30157092 DC : 0 ISO/DIS 21789 - GAS TURBINE APPLICATIONS - SAFETY
I.S. EN 60079-0:2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011 (MOD))
08/30186575 DC : DRAFT JULY 2008 BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"
BS EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines)
BS IEC 61892-6:2013 Mobile and fixed offshore units. Electrical installations Installation
12/30260078 DC : 0 BS EN 60092-502 IEC 60092-502 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 502: TANKERS - SPECIAL FEATURES
14/30312016 DC : 0 BS EN ISO/IEC 60079-13 - EXPLOSIVE ATMOSPHERES - PART 13: EQUIPMENT PROTECTION BY PRESSURIZED ROOM 'P' AND ARTIFICIALLY VENTILATED ROOM 'V'
ISO/TS 19880-1:2016 Gaseous hydrogen Fuelling stations Part 1: General requirements
I.S. EN 60079-30-2:2017 EXPLOSIVE ATMOSPHERES - PART 30-2: ELECTRICAL RESISTANCE TRACE HEATING - APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
18/30369304 DC : DRAFT APR 2018 BS EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
BS EN 50174-3 : 2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
UNE-EN 50050-3:2014 Electrostatic hand-held spraying equipment - Safety requirements - Part 3: Hand-held spraying equipment for ignitable flock
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
DIN EN 1473:2016-10 Installation and equipment for liquefied natural gas - Design of onshore installations
BS EN 1755:2015 Industrial Trucks. Safety requirements and verification. Supplementary requirements for operation in potentially explosive atmospheres
BS EN 50174-2 : 2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
IEC 62086-2:2001 Electrical apparatus for explosive gas atmospheres - Electrical resistance trace heating - Part 2: Application guide for design, installation and maintenance
EN 50176:2009 Stationary electrostatic application equipment for ignitable liquid coating material - Safety requirements
EN 50177:2009/A1:2012 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE COATING POWDERS - SAFETY REQUIREMENTS
EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
EN 50050-3:2013 Electrostatic hand-held spraying equipment - Safety requirements - Part 3: Hand-held spraying equipment for ignitable flock
EN 62086-2:2005 Electrical apparatus for explosive gas atmospheres - Electrical resistance trace heating - Part 2: Application guide for design, installation and maintenance
09/30182356 DC : 0 BS EN 12581:2005/A1 - COATING PLANTS - MACHINERY FOR DIP COATING AND ELECTRODEPOSITION OF ORGANIC LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
CEI EN 60079-13 : 2011 EXPLOSIVE ATMOSPHERES - PART 13: EQUIPMENT PROTECTION BY PRESSURIZED ROOMS 'P'
03/300201 DC : DRAFT FEB 2003 IEC 60079-0 ED.4.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
11/30248842 DC : 0 BS EN 50050-1:2011 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 1: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIALS
BS EN 60079-29-2:2015 Explosive atmospheres Gas detectors. Selection, installation, use and maintenance of detectors for flammable gases and oxygen
BS EN 62086-2:2005 Electrical apparatus for explosive gas atmospheres. Electrical resistance trace heating Application guide for design, installation and maintenance
EN 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
CEI EN 50176 : 2010 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
EN 50174-2 : 2009 AMD 2 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
IEC TR 61340-1:2012 Electrostatics - Part 1: Electrostatic phenomena - Principles and measurements
S.R. HD 60364-6:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION
IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
I.S. EN 50176:2009 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
I.S. EN 60079-15:2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
C22.1-15 PACKAGE Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference
CEI EN 50174-3 : 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
I.S. EN 50177:2009 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE COATING POWDERS - SAFETY REQUIREMENTS
NF EN 50174-2 : 2009 AMD 1 2011 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
CEI EN 60079-15 : 2012 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
BIS IS/IEC 60079-15 : 2005 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS
IEC TS 60079-43:2017 Explosive atmospheres - Part 43: Equipment in adverse service conditions
I.S. EN 62086-2:2005 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL RESISTANCE TRACE HEATING - PART 2: APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
DIN EN 12581:2011-02 Coating plants - Machinery for dip coating and electrodeposition of organic liquid coating material - Safety requirements (includes Amendment A1:2010)
DIN EN 12981:2010-06 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
BS EN 12981 : 2005 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
09/30206527 DC : 0 BS EN 60079-0 ED 6.0 - EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BS EN 1473:2016 Installation and equipment for liquefied natural gas. Design of onshore installations
EEMUA 181 : 1995 GUIDE TO RISK BASED ASSESSMENTS OF IN-SITU LARGE EX 'E' AND EX 'N' MACHINES
BIS IS/IEC 60079-0 : 2011 EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
DIN EN 1755:2016-02 Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres
DIN EN 1473:1997-11 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
DIN EN 1776:2016-05 GAS INFRASTRUCTURE - GAS MEASURING SYSTEMS - FUNCTIONAL REQUIREMENTS
I.S. EN 12981:2005 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
I.S. EN 1755:2015 INDUSTRIAL TRUCKS - SAFETY REQUIREMENTS AND VERIFICATION - SUPPLEMENTARY REQUIREMENTS FOR OPERATION IN POTENTIALLY EXPLOSIVE ATMOSPHERES
ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
I.S. EN 1473:2016 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
C22.1HB-18 Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
I.S. EN 1776:2015 GAS INFRASTRUCTURE - GAS MEASURING SYSTEMS - FUNCTIONAL REQUIREMENTS
I.S. EN 12581:2006 COATING PLANTS - MACHINERY FOR DIP COATING AND ELECTRODEPOSITION OF ORGANIC LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
VDI 2260:2003-10 Technical warranty for gas cleaning equipment - Particulate and gaseous matter
VDI/VDE/DGQ/DKD 2622 Blatt 20:2013-12 Calibration of measuring equipment for electrical quantities - Direct-voltage measuring amplifiers
VDI 2263 Blatt 5.1:2014-10 Dust fires and dust explosions - Hazards, assessment, protective measures - Explosion protection in fluid bed dryers - Hints and examples of operation
VDI 2330 Blatt 1:2013-09 Screw conveyors for bulk materials - General characterisation
CEI EN 50050-2 : 2014 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
CSA C22.4 No. 1 : 2009(R2018) OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE
I.S. EN 15001-2:2008 GAS INFRASTRUCTURE - GAS INSTALLATION PIPEWORK WITH AN OPERATING PRESSURE GREATER THAN 0,5 BAR FOR INDUSTRIAL INSTALLATIONS AND GREATER THAN 5 BAR FOR INDUSTRIAL AND NON INDUSTRIAL INSTALLATIONS - PART 2: DETAILED FUNCTIONAL REQUIREMENTS FOR COMMISSIONING, OPERATION AND MAINTENANCE
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
BS EN 50050-2:2013 Electrostatic hand-held spraying equipment. Safety requirements Hand-held spraying equipment for ignitable coating powder
13/30271407 DC : DRAFT DEC 2013 BS ISO 16924 - NATURAL GAS FUELLING STATIONS - LNG STATIONS FOR FUELLING VEHICLES
PREN 1473 : DRAFT 2018 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
I.S. EN 50174-2:2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
NF EN 15001-2 : 2009 GAS INFRASTRUCTURE - GAS INSTALLATION PIPEWORK WITH AN OPERATING PRESSURE GREATER THAN 0,5 BAR FOR INDUSTRIAL INSTALLATIONS AND GREATER THAN 5 BAR FOR INDUSTRIAL AND NON-INDUSTRIAL INSTALLATIONS - PART 2: DETAILED FUNCTIONAL REQUIREMENTS FOR COMMISSIONING, OPERATION AND MAINTENANCE
12/30260552 DC : 0 BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
10/30230365 DC : 0 BS EN 50050-2 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
EN 1473:2016 Installation and equipment for liquefied natural gas - Design of onshore installations
05/30128234 DC : DRAFT FEB 2005 EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
CEI EN 50050-1 : 2014 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 1: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIALS
BS EN 50050-3:2013 Electrostatic hand-held spraying equipment. Safety requirements Hand-held spraying equipment for ignitable flock
UNE-EN 50176:2010 Stationary electrostatic application equipment for ignitable liquid coating material - Safety requirements
04/30113660 DC : DRAFT MAY 2004 IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E'
NF EN 62086-2 : 2006 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL RESISTANCE TRACE HEATING - PART 2: APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
BS EN 50223:2015 Stationary electrostatic application equipment for ignitable flock material. Safety requirements
BS IEC 60092-502:1999 Electrical installation in ships Tankers. Special features
EN 60079-30-2:2017 Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance
CSA PLUS 2203 : 2001 HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES
SAE J2578_201408 Recommended Practice for General Fuel Cell Vehicle Safety
BS ISO 21789:2009 Gas turbine applications — Safety
IEC 61779-6:1999 Electrical apparatus for the detection and measurement of flammable gases - Part 6: Guide for the selection, installation, use and maintenance of apparatus for the detection and measurement of flammable gases
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
NF EN 60079-30-2 : 2007 ELECTRICAL ATMOSPHERES - PART 2: ELECTRICAL RESISTANCE TRACE HEATING - APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
I.S. EN 60079-29-2:2015 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
I.S. EN 50050-2:2013 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
NFC 01 426 : 2008 AMD 1 2015 ELECTROTECHNICAL VOCABULARY - PART 426: EQUIPMENT FOR EXPLOSIVE ATMOSPHERES
UNI EN 15001-2 : 2009 GAS INFRASTRUCTURE - GAS INSTALLATION PIPEWORK WITH AN OPERATING PRESSURE GREATER THAN 0,5 BAR FOR INDUSTRIAL INSTALLATIONS AND GREATER THAN 5 BAR FOR INDUSTRIAL AND NON-INDUSTRIAL INSTALLATIONS - PART 2: DETAILED FUNCTIONAL REQUIREMENTS FOR COMMISSIONING, OPERATION AND MAINTENANCE
I.S. EN 50174-3:2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
BIS IS/IEC 60079-30-2 : 2007 EXPLOSIVE ATMOSPHERES - PART 30: ELECTRICAL RESISTANCE TRACE HEATING - SECTION 2: APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
IEC 60079-15:2017 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
PREN 50174-3 : DRAFT 2012 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
ISO 21789:2009 Gas turbine applications — Safety
IEC 60092-502:1999 Electrical installations in ships - Part 502: Tankers - Special features
EEMUA 186 : 2016 A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
04/30112692 DC : DRAFT APR 2004 IEC 60364 ED.1 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 6: VERIFICATION
UNE-EN 1755:2016 Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres
12/30261012 DC : 0 BS IEC 61892-6 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 6: INSTALLATION
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
IEC 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
UNI EN 12581 : 2010 COATING PLANTS - MACHINERY FOR DIP COATING AND ELECTRODEPOSITION OF ORGANIC LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
UNI EN 12981 : 2009 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
CSA E60079.14 : 2002 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL INSTALLATIONS IN EXPLOSIVE GAS ATMOSPHERES (OTHER THAN MINES)
CSA CE CODE SAFETY PACKAGE : 2012 CE CODE SAFETY PACKAGE
UNE-EN 50223:2016 Stationary electrostatic application equipment for ignitable flock material - Safety requirements
BS EN 50176:2009 Stationary electrostatic application equipment for ignitable liquid coating material. Safety requirements
04/30105027 DC : DRAFT JUNE 2004 ISO 21789 - GAS TURBINES - SAFETY
CSA C22.4 PACKAGE : 2009 CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS
UNE-EN 60079-13:2011 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p"
07/30168628 DC : 0 BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"
BS EN 60079-13:2017 Explosive atmospheres Equipment protection by pressurized room \'p\' and artificially ventilated room \'v\'
PREN 50050-3 : DRAFT 2011 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK
PREN 50050-2 : DRAFT 2011 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
04/30068318 DC : DRAFT APR 2004 IEC 62086-2 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL RESISTANCE TRACE HEATING - PART 2: APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
11/30248845 DC : 0 BS EN 50050-2:2011 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
ISO 16924:2016 Natural gas fuelling stations — LNG stations for fuelling vehicles
I.S. EN 50050-3:2013 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK
BS EN 50177 : 2009 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE COATING POWDERS - SAFETY REQUIREMENTS
ISA TR12.21.01 : 2004 USE OF FIBER OPTIC SYSTEMS IN CLASS 1 HAZARDOUS (CLASSIFIED) LOCATIONS
I.S. EN ISO 16924:2018 NATURAL GAS FUELLING STATIONS - LNG STATIONS FOR FUELLING VEHICLES (ISO 16924:2016)
I.S. EN 61241-17:2005 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
IEC 60079-0:2017 Explosive atmospheres - Part 0: Equipment - General requirements
GOST R 52350.15 : 2005 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS
CEI EN 60079-29-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
UNE-EN 50050-1:2014 Electrostatic hand-held spraying equipment - Safety requirements - Part 1: Hand-held spraying equipment for ignitable liquid coating materials
I.S. HD 60364-6:2007 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 61892-7:2014 Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas
IEC 60079-30-2:2007 Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance
UNE-EN 1776:2017 Gas infrastructure - Gas measuring systems - Functional requirements
05/30138005 DC : DRAFT AUG 2005 IEC 60079-14 ED 4 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
UNE-EN 60079-0:2013 Explosive atmospheres - Part 0: Equipment - General requirements
17/30361391 DC : 0 BS EN 50174-2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
BS EN 1776:2015 Gas infrastructure. Gas measuring systems. Functional requirements
12/30276304 DC : 0 BS EN 61892-7 ED 3.0 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 7: HAZARDOUS AREAS
UNE-HD 60364-6:2017 Low-voltage electrical installations - Part 6: Verification
BS ISO 19372:2015 Microturbines applications. Safety
IEC 60079-29-2:2015 RLV Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
05/30134569 DC : DRAFT JUN 2005 IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
EI Model code of safe practice Part 15:2015 MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS
EN 1755:2015 Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres
EN 15001-2:2008 Gas infrastructure - Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations - Part 2: Detailed functional requirements for commissioning, operation and maintenance
EN 1776:2015 Gas infrastructure - Gas measuring systems - Functional requirements
EN 12581:2005+A1:2010 Coating plants - Machinery for dip coating and electrodeposition of organic liquid coating material - Safety requirements
UNE-EN 60079-30-2:2017 Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance
UNE-EN 60079-15:2013 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
UNE-EN 50177:2010 Stationary electrostatic application equipment for ignitable coating powders - Safety requirements
CEI EN 50050-3 : 2014 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK
BS IEC 62086-2 : 2001 AMD 16068 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL RESISTANCE TRACE HEATING - PART 2: APPLICATION GUIDE FOR DESIGN, INSTALLATION AND MAINTENANCE
ISO 19372:2015 Microturbines applications — Safety
I.S. EN 50050-1:2013 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 1: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE LIQUID COATING MATERIALS
I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
14/30297213 DC : 0 BS EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
PD IEC/TS 60079-43:2017 Explosive atmospheres Equipment in adverse service conditions
14/30267605 DC : 0 BS EN 60079-30-2 ED 1.0 - EXPLOSIVE ATMOSPHERES - PART 30-2: ELECTRICAL RESISTANCE TRACE HEATING - APPLICATION GUIDE FOR DESIGN; INSTALLATION AND MAINTENANCE
BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
IEC 60364-6:2016 Low voltage electrical installations - Part 6: Verification
UNE-EN 60079-29-2:2016 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
EN ISO 16924:2018 Natural gas fuelling stations - LNG stations for fuelling vehicles (ISO 16924:2016)
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
I.S. EN 50223:2015 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE FLOCK MATERIAL - SAFETY REQUIREMENTS
IEC 61892-6:2013 Mobile and fixed offshore units - Electrical installations - Part 6: Installation
I.S. EN 60079-13:2017 EXPLOSIVE ATMOSPHERES - PART 13: EQUIPMENT PROTECTION BY PRESSURIZED ROOM 'P' AND ARTIFICIALLY VENTILATED ROOM 'V'
PD 60079-14:2000 Guide to application of BS EN 60079-14
12/30269297 DC : 0 BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
BS EN 12581 : 2005 COATING PLANTS - MACHINERY FOR DIP COATING AND ELECTRODEPOSITION OF ORGANIC LIQUID COATING MATERIAL - SAFETY REQUIREMENTS
BS IEC 61892-7:2014 Mobile and fixed offshore units. Electrical installations Hazardous areas
IEC 60079-0:2017 RLV Explosive atmospheres - Part 0: Equipment - General requirements
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN 12981:2005+A1:2009 Coating plants - Spray booths for application of organic powder coating material - Safety requirements
HD 60364-6:2016/AC:2017-11 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION (IEC 60364-6:2016/COR1:2017)
EN 60079-29-2:2015 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
DIN EN 15001-2:2010-04 Gas infrastructure - Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations - Part 2: Detailed functional requirements for commissioning, operation and maintenance
EN 50050-2:2013 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER
EN 50050-1:2013 Electrostatic hand-held spraying equipment - Safety requirements - Part 1: Hand-held spraying equipment for ignitable liquid coating materials
EN 50223:2015 Stationary electrostatic application equipment for ignitable flock material - Safety requirements
CSA C22.2 No. 60079-15 : 2016 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
ISA 12.16.01 : 2002 ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY
CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS

IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-19:2010+AMD1:2015 CSV Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
ISO 31000:2009 Risk management Principles and guidelines
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 60079-10-1:2015 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60364-6:2016 Low voltage electrical installations - Part 6: Verification
AS/NZS IEC 60079.15:2020 Explosive atmospheres Equipment protection by type of protection "n"
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 61241-4:2001 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.