EN 60684-2:2011
Current
The latest, up-to-date edition.
Flexible insulating sleeving - Part 2: Methods of test
16-09-2011
FOREWORD
INTRODUCTION
1 General
2 Test conditions
3 Measurements of bore, wall thickness
and concentricity
4 Density
5 Resistance to splitting after heating
6 Heat shock (resistance to heat)
7 Resistance to soldering heat
8 Loss in mass on heating of uncoated textile
glass sleeving
9 Longitudinal change
10 Deformation under load (resistance to pressure
at elevated temperature)
11 Thermal stability of PVC sleeving
12 Volatile content of silicone sleeving
13 Bending after heating
14 Bending at low temperature
15 Brittleness temperature
16 Dimensional stability on storage (applicable to
heat-shrinkable sleeving only)
17 Hydrolysis of coating
18 Flexibility (extruded sleeving only)
19 Tensile strength, tensile stress at 100%
elongation, elongation at break and secant
modulus at 2% elongation
20 Fraying resistance test
21 Breakdown voltage
22 Insulation resistance
23 Volume resistivity
24 Permittivity and dissipation factor
25 Resistance to tracking
26 Flame propagation tests
27 Oxygen index
28 Transparency
29 Ionic impurities test
30 Silver staining test
31 Electrolytic corrosion resistance
32 Corrosion resistance (tensile and elongation)
33 Copper corrosion (presence of corrosive volatiles)
34 Colour fastness to light
35 Resistance to ozone
36 Resistance to selected fluids
37 Thermal endurance
38 Mass per unit length
39 Heat ageing
40 Water absorption
41 Restricted shrinkage (applicable to heat-shrinkable
sleeving only)
42 Colour stability to heat
43 Smoke index
44 Toxicity index
45 Halogen content
46 Acid gas generation
47 Hot elongation and hot set
48 Tension set (applicable to elastomeric sleeving
only)
49 Tear propagation (applicable to elastomeric
sleeving only)
50 Long term heat ageing (3000 h)
51 Dynamic shear at ambient temperature
52 Dynamic shear at elevated temperature
53 Dynamic shear after heat shock and heat ageing
54 Rolling drum peel to aluminium
55 Aluminium rod dynamic shear
56 Sealing
57 Adhesive T peel strength of two bonded
heat-shrinkable substrates
58 Circumferential extension
59 Voltage proof
60 Thermal shock
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60684-2:2011 gives methods of test for flexible insulating sleeving, including heat-shrinkable sleeving, intended primarily for insulating electrical conductors and connections of electrical apparatus, although they may be used for other purposes. The tests specified are designed to control the quality of the sleeving but it is recognized that they do not completely establish the suitability of sleeving for impregnation or encapsulation processes or for other specialized applications. Where necessary, the test methods in this part will need to be supplemented by appropriate impregnation or compatibility tests to suit the individual circumstances. The main changes from the previous edition are as follows: three additional methods for circumferential extension, voltage proof and thermal shock and alignment with North American methods.
Committee |
CLC/SR 15
|
DevelopmentNote |
Supersedes HD 523.2 (05/2001) Supersedes UNE EN 60684-2. (09/2014)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 60684-2:2011 | Identical |
NBN EN 60684-2 : 2011 | Identical |
NEN EN IEC 60684-2 : 2011 | Identical |
I.S. EN 60684-2:2011 | Identical |
PN EN 60684-2 : 2011 | Identical |
SN EN 60684-2 : 1997 AMD 2 2005 | Identical |
VDE 0341-2 : 2012 | Identical |
DIN EN 60684-2 : 2012 | Identical |
BS EN 60684-2:2011 | Identical |
CEI EN 60684-2 : 2012 | Identical |
NF EN 60684-2 : 2012 | Identical |
PNE-FprEN 60684-2 | Identical |
UNE-EN 60684-2:2011 | Identical |
BS EN 60684-3-233:2006 | Flexible insulating sleeving Specifications for individual types of sleeving - Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
16/30346516 DC : 0 | BS EN 4708-106 - AEROSPACE SERIES - SLEEVING, HEAT-SHRINKABLE, FOR BINDING, INSULATION AND IDENTIFICATION - PART 106: LIMITED FIRE HAZARD SLEEVING - TEMPERATURE RANGE -30 DEGREES C TO 105 DEGREES C - PRODUCT STANDARD |
BS EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables General introduction |
I.S. EN 60684-3-284:2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 284: HEAT-SHRINKABLE, SLEEVINGS, FOR OIL BARRIER APPLICATIONS |
UNE-EN 50525-1:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
BS EN 50655-2:2017 | Electric cables. Accessories. Material characterization Fingerprinting for heat shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
CEI EN 50143 : 2012 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
BS EN 60684-3-343 to 345:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Expandable braided ethylene chlorotrifluoroethylene (E-CTFE) textile sleeving, uncoated |
I.S. EN 60684-3-320:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 320: POLYETHYLENE TEREPHTHALATE TEXTILE SLEEVING, LIGHTLY IMPREGNATED |
BS EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V |
CEI EN 60684-3-151 : 1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 151: EXTRUDED PVC/NITRILE RUBBER - GENERAL PURPOSE |
BS EN 50363-2-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric covering compounds |
BS EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
BS 7933-2:2007 | Electric cables. Accessories. Material characterisation Fingerprinting and type tests for heat shrinkable components for low voltage applications |
BS EN 60684-3-240 to 243:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Heat-shrinkable PTFE sleeving |
CEI EN 50290-2-36 : 1ED 2017 | COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND |
BS EN 60684-3-211:2007 | Flexible insulating sleeving Specifications for individual types of sleeving - Heat-shrinkable sleeving, semi-rigid polyolefin, shrink ratio 2:1 |
BS EN 60684-3.246 : 2007 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 246: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED |
BS EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC) |
CEI 20-95 : 2010 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
BS EN 60684-3-229:2003 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Heat-shrinkable semi-flexible, polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
BS EN 60684-3-165:2004 | Flexible insulating sleeving. Specifications for individual types of sleeving Extruded Polyolefin, flame retarded, limited fire hazard sleeving |
BS EN 60684-1:2003 | Flexible insulating sleeving Definitions and general requirements |
CEI EN 60684-3-116 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 116 AND 117: EXTRUDED POLYCHLOROPRENE, GENERAL PURPOSE |
I.S. EN 60684-3-218:1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 218: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, NOT FLAME RETARDED SHRINK RATIO 3:1 |
PREN 50655-2 : DRAFT 2015 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
BS EN 50363-6 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS |
I.S. EN 60684-3-214:2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 214: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
CEI EN 60684-3-228 : 2005 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 228: HEAT-SHRINKABLE, SEMI-RIGID POLYVINYLIDENE FLUORIDE SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
I.S. EN 50363-0:2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION |
I.S. EN 60684-1:2003 | FLEXIBLE INSULATING SLEEVING - PART 1: DEFINITIONS AND GENERAL REQUIREMENTS |
I.S. EN 50363-10-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-2: MISCELLANEOUS SHEATHING COMPOUNDS - THERMOPLASTIC POLYURETHANE |
CEI EN 60684-3-247 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
I.S. EN 4708-104:2017 | AEROSPACE SERIES - SLEEVING, HEAT-SHRINKABLE, FOR BINDING, INSULATION AND IDENTIFICATION - PART 104: SEMI-RIGID POLYVINYLIDENE FLUORIDE (PDVF) - OPERATING TEMPERATURE -55 DEGREES C TO 175 DEGREES C - PRODUCT STANDARD |
HD 631.2 : 2007 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
BS EN 60684-3-212:2006 | Flexible insulating sleeving Specifications for individual types of sleeving - Heat-shrinkable polyolefin sleevings |
I.S. EN 50363-7:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 7: HALOGEN-FREE, THERMOPLASTIC INSULATING COMPOUNDS |
I.S. EN 60684-3-248:2007 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 248: GENERAL PURPOSE, HEAT-SHRINKABLE, DUAL WALL POLYOLEFIN SLEEVING, FLAME RETARDED, SHRINK RATIOS 2:1, 3:1, 4:1 |
I.S. EN 50306-4:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLE STANDARD WALL SHEATHED |
I.S. EN 60684-3-216:2005 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 216: HEAT-SHRINKABLE, FLAME-RETARDED, LIMITED-FIRE HAZARD SLEEVING |
I.S. EN 50363-2-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
I.S. EN 60684-3-212:2006 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 212: HEAT-SHRINKABLE POLYOLEFIN SLEEVINGS |
UNE-EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
EN 50363-2-1 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
EN 50363-8 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS |
EN 60684-3-406 to 408:2003 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 406 to 408: Glass textile sleeving with PVC coating |
EN 60684-3-281 : 2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 281: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, SEMICONDUCTIVE |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
EN 60684-3-229:2003 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 229: Heat-shrinkable semi-flexible, polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
EN 60684-3-282 : 2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 282: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING - STRESS CONTROL |
EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC) |
EN 60684-3-320:2002 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 320: Polyethylene terephthalate textile sleeving, lightly impregnated |
EN 60684-3-240 to 243:2002 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 240 to 243: Heat-shrinkable PTFE sleeving |
EN 60684-3-228:2004 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 228: Heat-shrinkable, semi-rigid polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
EN 60684-3-145 to 147:2001 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 145 to 147: Extruded PTFE sleeving |
EN 60684-3-211:2007 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 211: Heat-shrinkable sleeving, semi-rigid polyolefin, shrink ratio 2:1 |
EN 60684-3-218:1998 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 218: Heat-shrinkable polyolefin sleeving, not flame retarded, shrink ratio 3:1 |
EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC) |
EN 60684-3-209:2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 209: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, GENERAL PURPOSE, FLAME RETARDED |
EN 60684-3-271:2011 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 271: Heat-shrinkable elastomer sleevings, flame retarded, fluid resistant, shrink ratio 2:1 |
EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
EN 60684-3-284:2014 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 284: Heat-shrinkable, sleevings, for oil barrier applications |
EN 50363-6 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS |
EN 60684-1:2003 | Flexible insulating sleeving - Part 1: Definitions and general requirements |
HD 22.13 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
EN 50363-7:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds |
EN 50264-2:2002 | Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables |
CEI EN 60684-3-248 : 2008 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 248: GENERAL PURPOSE, HEAT-SHRINKABLE, DUAL WALL POLYOLEFIN SLEEVING, FLAME RETARDED, SHRINK RATIOS 2:1, 3:1, 4:1 |
BS EN 60684-3-218:1998 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Heat-shrinkable polyolefin sleeving, not flame retarded, shrink ratio 3:1 |
EN 60684-3-100 to 105:2001 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 100 to 105: Extruded PVC sleeving |
BS EN 60684-3-285:2014 | Flexible insulating sleeving Specifications for individual types of sleeving. Sheet 285: Heat-shrinkable polyolefin sleeving, for medium voltage joint insulation |
BS EN 60684-3-282:2010 | Flexible insulating sleeving Specifications for individual types of sleeving. Heat-shrinkable, polyolefin sleeving. Stress control |
01/206396 DC : DRAFT SEP 2001 | PRHD 21.14 S1 - CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 14: FLEXIBLE CABLES (CORDS), INSULATED AND SHEATHED WITH HALOGEN-FREE THERMOPLASTIC COMPOUNDS |
05/30133180 DC : 0 | EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
CEI EN 50306-4 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED |
I.S. EN 60684-3-121 TO 124:2001 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 121 TO 124: EXTRUDED SILICONE SLEEVING |
BS EN 60684-3-409:1999 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Glass textile sleeving with polyurethane (PUR)-based coating |
BS EN 60684-3-136:1998 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Extruded fluorosilicone sleeving. General purpose |
BS EN 60684-3-116 and 117:2003 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Extruded polychloroprene. General purpose |
CEI EN 60684-3-285 : 2016 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 285: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, FOR MEDIUM VOLTAGE JOINT INSULATION |
CEI EN 60684-3-212 : 2006 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 212: HEAT-SHRINKABLE POLYOLEFIN SLEEVINGS |
BS EN 4708-104:2017 | Aerospace series. Sleeving, heat-shrinkable, for binding, insulation and identification Semi-rigid polyvinylidene fluoride (PDVF). Operating temperature - 55 °C to 175 °C. Product Standard |
BS EN 60684-3-145 to 147:2001 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Extruded PTFE sleeving |
CEI EN 60684-3-209 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 209: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, GENERAL PURPOSE, FLAME RETARDED |
I.S. EN 60684-3-420 TO 422:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 420 TO 422: POLYETHYLENE TEREPHTHALATE TEXTILE SLEEVING WITH ACRYLIC BASED COATING |
I.S. HD 22.9:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
I.S. EN 50363-10-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-1: MISCELLANEOUS SHEATHING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
I.S. EN 60684-3-246:2007 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 246: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED |
I.S. EN 50264-2:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 2: SINGLE CORE CABLES |
I.S. EN 50655-2:2017 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
I.S. EN 60684-3-209:2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 209: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, GENERAL PURPOSE, FLAME RETARDED |
I.S. HD 631.2:2007 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
I.S. EN 60684-3-116 AND 117:2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 116 AND 117: EXTRUDED POLYCHLOROPRENE - GENERAL PURPOSE |
CEI EN 60684-3-409 : 2001 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 409: GLASS TEXTILE SLEEVING WITH POLYURETHANE (PUR)-BASED COATING |
CEI EN 60684-3-300 : 2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 300: GLASS TEXTILE FIBRE SLEEVING, BRAIDED, UNCOATED |
I.S. EN 50363-5:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
EN 50306-1:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements |
VDE 0341-3-136 : 1999 | FLEXIBLE INSULATING SLEEVING - SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - EXTRUDED FLUOROSILICONE SLEEVING - GENERAL PURPOSE |
DIN EN 60684-3-151 : 1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING; SHEET 151: EXTRUDED PVC/NITRILE SLEEVING; GENERAL PURPOSE |
DIN EN 60684-3-136 : 1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 136: EXTRUDED FLUOROSILICONE SLEEVING - GENERAL PURPOSE |
VDE 0341-3-151 : 1999 | FLEXIBLE INSULATING SLEEVING - SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING; EXTRUDED PVC/NITRILE SLEEVING; GENERAL PURPOSE |
VDE 0341-3-233 : 2006 COR 1 2008 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 233: HEAT-SHRINKABLE, FLUOROELASTOMER SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
VDE 0341-3-409 : 2000 | FLEXIBLE INSULATING SLEEVING - SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - GLASS TEXTILE SLEEVING WITH POLYURETHANE (PUR)-BASED COATING |
DIN EN 60684-3-409 : 2000 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 409: GLASS TEXTILE SLEEVING WITH POLYURETHANE (PUR)-BASED COATING |
BS EN 60684-3-300:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Glass textile fibre sleeving, braided, uncoated |
BS EN 50306-1:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements |
BS EN 60684-3-205:2011 | Flexible insulating sleeving Specifications for individual types of sleeving. Sheet 205: Heat-shrinkable chlorinated polyolefin sleeving, flame retarded, nominal shrink ratio 1,7:1 and 2:1 |
BS EN 50382-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
15/30325653 DC : 0 | BS EN 50655-2 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
I.S. EN 50363-4-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-1: PVC SHEATHING COMPOUNDS |
BS EN 50264-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance General requirements |
BS EN 50525-1:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) General requirements |
CEI EN 60684-3-281 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 281: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, SEMICONDUCTIVE |
CEI EN 60684-3-271 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 271: HEAT-SHRINKABLE ELASTOMER SLEEVINGS, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
BS EN 60684-3-248:2007 | Flexible insulating sleeving. Specifications for individual types of sleeving General purpose, heat-shrinkable, dual wall polyolefin sleeving, flame retarded, shrink ratios 2:1, 3:1, 4:1 |
I.S. EN 50290-2-36:2016 | COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND |
CEI EN 60684-3-211 : 2007 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 211: HEAT-SHRINKABLE SLEEVING, SEMI-RIGID POLYOLEFIN, SHRINK RATIO 2:1 |
BS EN 50306-2:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables |
CEI EN 50306-2 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES |
CEI EN 60684-3-284 : 2016 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 284: HEAT-SHRINKABLE, SLEEVINGS, FOR OIL BARRIER APPLICATIONS |
BS EN 60684-3-217:1998 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Heat-shrinkable polyolefin sleeving, flame retarded, shrink ratio 3:1 |
BS EN 60684-3-400 to 402:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Glass textile sleeving with silicone elastomer coating |
EN 50655-2:2017 | Electric cables - Accessories - Material characterization - Part 2: Fingerprinting for heat shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
UNE-EN 50290-2-36:2016 | Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound |
I.S. EN 50525-1:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 1: GENERAL REQUIREMENTS |
BS EN 60684-3-280 : 2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 280: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, ANTI-TRACKING |
I.S. EN 50382-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 50363-8 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS |
I.S. EN 60684-3-271:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 271: HEAT-SHRINKABLE ELASTOMER SLEEVINGS, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
I.S. EN 60684-3-285:2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 285: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, FOR MEDIUM VOLTAGE JOINT INSULATION |
I.S. EN 60684-3-406 TO 408:2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 406 TO 408: GLASS TEXTILE SLEEVING WITH PVC COATING |
I.S. EN 50363-3:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
I.S. EN 50264-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
CEI EN 60684-3-246 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 246: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED |
CEI EN 60684-3-165 : 2005 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 165: EXTRUDED POLYOLEFIN, FLAME RETARDED, LIMITED FIRE HAZARD SLEEVING |
BS EN 50264-2:2002 | Railway applications. Railway rolling stock cables having special fire performance. Standard wall Single core cables |
BS EN 60684-3-247 : 2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011) |
I.S. EN 60684-3-211:2007 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 211: HEAT-SHRINKABLE SLEEVING, SEMI-RIGID POLYOLEFIN, SHRINK RATIO 2:1 |
I.S. EN 50363-6:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS |
IEC 60684-3-216:2001+AMD1:2005+AMD2:2013 CSV | Flexible insulating sleeving - Part 3: Specifications for individualtypes of sleeving - Sheet 216: Heat-shrinkable, flame- retarded, limited-fire-hazard sleeving |
UNE-EN 50264-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements |
CEI EN 50306-3 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED |
CEI EN 60684-3-205 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 205: HEAT-SHRINKABLE CHLORINATED POLYOLEFIN SLEEVING, FLAME RETARDED, NOMINAL SHRINK RATIO 1,7:1 AND 2:1 |
CEI EN 60684-3-214 : 2015 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 214: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
BS EN 50264-3:2002 | Railway applications. Railway rolling stock cables having special fire performance. Standard wall Multicore cables |
BS EN 60684-3-406 to 408:2003 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Glass textile sleeving with PVC coating |
BS EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds |
BS EN 60684-3-320:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Polyethylene terephthalate textile sleeving, lightly impregnated |
BS EN 60684-3-151:1998 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Extruded PVC/nitrile rubber. General purpose |
CEI EN 60684-3-233 : 2006 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 233: HEAT-SHRINKABLE FLUOROELASTOMER SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
CEI EN 60684-3-320 : 2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 320: POLYETHYLENE TEREPHTHALATE TEXTILE SLEEVING, LIGHTLY IMPREGNATED |
BS EN 60684-3-100 to 105:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Extruded PVC sleeving - Extruded PVC sleeving |
08/30188764 DC : 0 | BS EN 50525-1 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - CABLES FOR GENERAL APPLICATIONS |
BS EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables PVC sheathing compounds |
CEI EN 50306-1 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
BS EN 50363-4-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables PVC covering compounds |
BS EN 60684-3-420 to 422:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Polyethylene terephthalate textile sleeving with acrylic based coating |
I.S. EN 60684-3-282:2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 282: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING - STRESS CONTROL |
CEI EN 60684-3-282 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 282: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING - STRESS CONTROL |
BS EN 60684-3-403 to 405:2002 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Glass textile sleeving with acrylic based coating |
BS EN 60684-3-284:2014 | Flexible insulating sleeving Specifications for individual types of sleeving - Heat-shrinkable, sleevings, for oil barrier applications |
BS EN 60243-1:2013 | Electric strength of insulating materials. Test methods Tests at power frequencies |
CEI EN 60684-3-229 : 2003 | FLEXIBLE INSULATING SLEEVING - PART 3 : SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 229: HEAT SHRINKABLE SEMI-FLEXIBLE, POLYVINYLIDENE FLUORIDE SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
05/30136249 DC : 0 | EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 60684-3-214:2014 | Flexible insulating sleeving Specifications for individual types of sleeving. Heat-shrinkable, polyolefin sleeving, not flame retarded, thick and medium wall |
BS EN 50306-4:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed |
CEI EN 50264-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60684-3-403 TO 405:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 403 TO 405: GLASS TEXTILE SLEEVING WITH ACRYLIC BASED COATING |
BS EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC) |
BS EN 50363-7:2005 | Insulating, sheathing and covering materials for low voltage energy cables Halogen-free, thermoplastic insulating compounds |
EN 60684-3-116:2011 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 116 and 117: Extruded polychloroprene, general purpose |
BS EN 60684-3-283 : 2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 283: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, FOR BUS-BAR INSULATION |
EN 4708-104:2017 | Aerospace series - Sleeving, heat-shrinkable, for binding, insulation and identification - Part 104: Semi-rigid polyvinylidene fluoride (PDVF) - Operating temperature - 55 °C to 175 °C - Product Standard |
I.S. EN 50363-9-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
I.S. EN 50363-4-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-2: PVC COVERING COMPOUNDS |
I.S. EN 50363-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 1: CROSS-LINKED ELASTOMERIC INSULATING COMPOUNDS |
I.S. EN 60684-3-283:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 283: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, FOR BUS-BAR INSULATION |
I.S. EN 50363-2-2:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-2: CROSS-LINKED ELASTOMERIC COVERING COMPOUNDS |
I.S. EN 60684-3-247:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL |
I.S. EN 60684-3-409:2000 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 409: GLASS TEXTILE SLEEVING, WITH POLYURETHANE (PUR)-BASED COATING |
I.S. EN 50306-2:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES |
CEI EN 60243-1 : 2014 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES |
I.S. EN 60684-3-240 TO 243:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 240 TO 243: HEAT-SHRINKABLE PTFE SLEEVING |
I.S. EN 60684-3-229:2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 229: HEAT-SHRINKABLE SEMI-FLEXIBLE, POLYVINYLIDENE FLUORIDE SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
I.S. EN 60684-3-228:2004 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 228: HEAT-SHRINKABLE, SEMI-RIGID POLYVINYLIDENE FLUORIDE SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
I.S. EN 50306-1:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60684-3-340 TO 342:2003 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 340 TO 342: EXPANDABLE BRAIDED POLYETHYLENE TEREPHTHALATE TEXTILE SLEEVING |
EN 60684-3-212:2006/corrigendum:2006 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 212: Heat-shrinkable polyolefin sleevings |
EN 50306-2:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables |
EN 50306-3:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed |
EN 50306-4:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed |
EN 60684-3-420 to 422:2002 | Flexible insulating sleeving - Part 3: Specification for individual types of sleeving - Sheets 420 to 422: Polyethylene terephthalate textile sleeving with acrylic based coating |
EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds |
EN 50363-3 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
BS EN 50363-10-2:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Thermoplastic polyurethane |
CEI EN 60684-1 : 2003 | FLEXIBLE INSULATING SLEEVING - PART 1: DEFINITIONS AND GENERAL REQUIREMENTS |
BS EN 60684-3-228:2004 | Flexible insulating sleeving Specification requirements for individual types of sleeving - Heat-shrinkable, semi-rigid polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
CEI EN 60684-3-136 : 1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 136: EXTRUDED FLUOROSILICONE SLEEVING - GENERAL PURPOSE |
BS EN 60684-3-116:2011 | Flexible insulating sleeving Specifications for individual types of sleeving. Sheets 116 and 117: Extruded polychloroprene, general purpose |
BS EN 60684-3-281:2010 | Flexible insulating sleeving Specifications for individual types of sleeving. Heat-shrinkable, polyolefin sleeving, semiconductive |
BS EN 60684-3-271:2004 | Flexible insulating sleeving Specifications for individual types of sleeving - Heat-shrinkable elastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1 |
I.S. EN 60684-3-151:1999 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 151: EXTRUDED PVC/NITRILE RUBBER - GENERAL PURPOSE |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS EN 60684-3-209:2010 | Flexible insulating sleeving Specifications for individual types of sleeving. Heat-shrinkable polyolefin sleeving, general purpose, flame retarded |
04/30109444 DC : DRAFT FEB 2004 | HD 22.13 S2 - HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
BS EN 50306-3:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed |
CEI EN 50525-1 : 2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 1: GENERAL REQUIREMENTS |
BS EN 60684-3-340 to 342:2003 | Specification for flexible insulating sleeving. Specification requirements for individual types of sleeving Expandable braided polyethylene terephthalate textile sleeving |
I.S. EN 60684-3-205:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 205: HEAT-SHRINKABLE CHLORINATED POLYOLEFIN SLEEVING, FLAME RETARDED, NOMINAL SHRINK RATIO 1,7:1 AND 2:1 |
BS EN 60684-3-216 : 2005 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 216: HEAT-SHRINKABLE, FLAME-RETARDED, LIMITED-FIRE HAZARD SLEEVING |
I.S. EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013 (EQV)) |
I.S. HD 22.13:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
I.S. EN 60684-3-400 TO 402:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 400 TO 402: GLASS TEXTILE SLEEVING WITH SILICONE ELASTOMER COATING |
I.S. EN 60684-3-300:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 300: GLASS TEXTILE FIBRE SLEEVING, BRAIDED, UNCOATED |
I.S. EN 50363-8:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS |
I.S. EN 50264-3:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 3: MULTICORE CABLES |
I.S. EN 60684-3-116:2011 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 116 AND 117: EXTRUDED POLYCHLOROPRENE, GENERAL PURPOSE (IEC 60684-3-116:2010) |
I.S. EN 60684-3-281:2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 281: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, SEMICONDUCTIVE |
UNE-EN 50143:2010 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
I.S. EN 60684-3-280:2010 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 280: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, ANTI-TRACKING |
I.S. EN 60684-3-343 TO 345:2002 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEETS 343 TO 345: EXPANDABLE BRAIDED ETHYLENE CHLOROTRIFLUOROETHYLENE (E-CTFE) TEXTILE SLEEVING, UNCOATED |
UNE-EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction |
I.S. EN 50393:2015 | TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV |
I.S. EN 50143:2009 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
I.S. EN 50306-3:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED |
I.S. EN 60684-3-233:2006 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 233: HEAT-SHRINKABLE FLUOROELASTOMER SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
I.S. EN 60684-3-217:2000 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 217: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, FLAME RETARDED SHRINK RATIO 3:1 |
EN 60684-3-280:2010/A1:2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 280: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, ANTI-TRACKING (IEC 60684-3-280:2010/A1:2013) |
EN 60684-3-247:2011/A1:2017 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011/A1:2016) |
EN 60684-3-340 to 342:2003 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 340 to 342: Expandable braided polyethylene terephthalate textile sleeving |
EN 60684-3-216:2005/A2:2014 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 216: HEAT-SHRINKABLE, FLAME-RETARDED, LIMITED-FIRE HAZARD SLEEVING (IEC 60684-3-216:2001 + CORRIGENDUM 2003 + A1:2005) |
EN 50290-2-36:2016 | Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound |
EN 50363-4-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds |
EN 60684-3-214:2014 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 214: Heat-shrinkable, polyolefin sleeving, not flame retarded, thick and medium wall |
EN 60684-3-409:1999 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 409: Glass textile sleeving with polyurethane (PUR)-based coating |
EN 50363-2-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds |
EN 60684-3-217:1998 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 217: Heat-shrinkable polyolefin sleeving, flame retarded shrink ratio 3:1 |
EN 60684-3-285:2014 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 285: Heat-shrinkable polyolefin sleeving, for medium voltage joint insulation |
EN 60684-3-400 to 402:2002 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 400 to 402: Glass textile sleeving with silicone elastomer coating |
EN 50363-10-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane |
EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction |
HD 22-9 : 200S3 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
EN 60684-3-121 to 124:2001 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 121 to 124: Extruded silicone sleeving |
EN 60684-3-248:2007 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin sleeving, flame retarded, shrink ratios 2:1, 3:1, 4:1 |
EN 60684-3-233:2006/corrigendum:2006 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 233: HEAT-SHRINKABLE FLUOROELASTOMER SLEEVING, FLAME RETARDED, FLUID RESISTANT, SHRINK RATIO 2:1 |
EN 60684-3-403 to 405:2002 | Flexible insulating sleeving - Part 3: Specification for individual types of sleeving - Sheets 403 to 405: Glass textile sleeving with acrylic based coating |
EN 60684-3-246:2007 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 246: Heat-shrinkable polyolefin sleeving, dual wall, not flame retarded |
EN 60684-3-116 & 117:2003 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 116 and 117: Extruded polychloroprene - General purpose |
EN 60684-3-165:2004 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 165: Extruded polyolefin, flame retarded, limited fire hazard sleeving |
EN 60684-3-151:1998 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 151: Extruded PVC/nitrile rubber - General purpose |
EN 50363-5 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
EN 50264-3:2002 | Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 3: Multicore cables |
EN 60684-3-343 to 345:2002 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheets 343 to 345: Expandable braided ethylene chlorotrifluoroethylene (E-CTFE) textile sleeving, uncoated |
EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds |
EN 60684-3-300:2002 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 300: Glass textile fibre sleeving, braided, uncoated |
EN 60684-3-205:2011 | Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 205: Heat-shrinkable chlorinated polyolefin sleeving, flame retarded, nominal shrink ratio 1,7:1 and 2:1 |
OVE EN 50290-2-27:2024 02 01 | Communication cables -- Part 2-27: Common design rules and construction - Halogen free polyolefin based sheathing compounds for cables having improved flame and fire properties (HFFR) (english version) |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
ISO 182-2:1990 | Plastics Determination of the tendency of compounds and products based on vinyl chloride homopolymers and copolymers to evolve hydrogen chloride and any other acidic products at elevated temperatures Part 2: pH method |
ISO 4589-3:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test |
EN ISO 62:2008 | Plastics - Determination of water absorption (ISO 62:2008) |
ISO 2921:2011 | Rubber, vulcanized Determination of low-temperature retraction (TR test) |
IEC 60212:2010 | Standard conditions for use prior to and during the testing of solid electrical insulating materials |
ISO 974:2000 | Plastics Determination of the brittleness temperature by impact |
IEC 60250:1969 | Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
IEC 60216-4-2:2000 | Electrical insulating materials - Thermal endurance properties - Part 4-2: Ageing ovens - Precision ovens for use up to 300 °C |
IEC 60216-4-1:2006 | Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber ovens |
ISO 105-B01:2014 | Textiles Tests for colour fastness Part B01: Colour fastness to light: Daylight |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 60216-4-2:2000 | Electrical insulating materials - Thermal endurance properties - Part 4-2: Ageing ovens - Precision ovens for use up to 300 °C |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
EN 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
HD 429 : 200S1 | METHODS OF TEST FOR VOLUME RESISTIVITY AND SURFACE RESISTIVITY OF SOLID ELECTRICAL INSULATING MATERIALS |
ISO 1431-1:2012 | Rubber, vulcanized or thermoplastic Resistance to ozone cracking Part 1: Static and dynamic strain testing |
IEC 60093:1980 | Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials |
IEC 60589:1977 | Methods of test for the determination of ionic impurities in electrical insulating materials by extraction with liquids |
ISO 5-4:2009 | Photography and graphic technology Density measurements Part 4: Geometric conditions for reflection density |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
IEC TS 60695-11-21:2005 | Fire hazard testing - Part 11-21: Test flames - 500 W vertical flame test method for tubular polymeric materials |
ISO 5-3:2009 | Photography and graphic technology Density measurements Part 3: Spectral conditions |
EN 60426:2007 | Electrical insulating materials - Determination of electrolytic corrosion caused by insulating materials - Test methods |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
ISO 5-1:2009 | Photography and graphic technology Density measurements Part 1: Geometry and functional notation |
EN ISO 4589-2:2017 | Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient-temperature test (ISO 4589-2:2017) |
ISO 62:2008 | Plastics Determination of water absorption |
IEC 60426:2007 | Electrical insulating materials - Determination of electrolytic corrosion caused by insulating materials - Test methods |
EN ISO 182-2:1999 | Plastics - Determination of the tendency of compounds and products based on vinyl chloride homopolymers and copolymers to evolve hydrogen chloride and any other acidic products at elevated temperatures - Part 2: pH method (ISO 182-2:1990) |
ISO 37:2017 | Rubber, vulcanized or thermoplastic — Determination of tensile stress-strain properties |
ISO 4589-2:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 2: Ambient-temperature test |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 60216-4-1:2006 | Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber ovens |
ISO 105-A02:1993 | Textiles Tests for colour fastness Part A02: Grey scale for assessing change in colour |
HD 602 : 200S1 | TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY |
EN ISO 105-B01:2014 | Textiles - Tests for colour fastness - Part B01: Colour fastness to light: Daylight (ISO 105-B01:2014) |
HD 381 : 200S1 | METHODS OF TEST FOR THE DETERMINATION OF IONIC IMPURITIES IN ELECTRICAL INSULATING MATERIALS BY EXTRACTION WITH LIQUIDS |
EN 60212:2011 | Standard conditions for use prior to and during the testing of solid electrical insulating materials |
EN ISO 4589-3:2017 | Plastics - Determination of burning behaviour by oxygen index - Part 3: Elevated-temperature test (ISO 4589-3:2017) |
ISO 5-2:2009 | Photography and graphic technology Density measurements Part 2: Geometric conditions for transmittance density |
ISO 182-1:1990 | Plastics Determination of the tendency of compounds and products based on vinyl chloride homopolymers and copolymers to evolve hydrogen chloride and any other acidic products at elevated temperatures Part 1: Congo red method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.