FOREWORD
1 General
2 Terms and definitions
3 Classification
4 Characteristics of circuit-breakers
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Co-ordination between a
        circuit-breaker and another short-circuit
        protective device associated in the same
        circuit
Annex B (normative) - Circuit-breakers incorporating
        residual current protection
Annex C (normative) - Individual pole short-circuit
        test sequence
Annex D - Vacant
Annex E (informative) - Items subject to agreement
        between manufacturer and user
Annex F (normative) - Additional tests for circuit-breakers
        with electronic over-current protection
Annex G (normative) - Power loss
Annex H (normative) - Test sequence for circuit-breakers
        for IT systems
Annex J (normative) - Electromagnetic compatibility
        (EMC) - Requirements and test methods for
        circuit-breakers
Annex K (informative) - Glossary of symbols and
        graphical representation of characteristics
Annex L (normative) - Circuit-breakers not fulfilling
        the requirements for overcurrent protection
Annex M (normative) - Modular residual current
        devices (without integral current breaking device)
Annex N (normative) - Electromagnetic compatibility
        (EMC) - Additional requirements and test methods
        for devices not covered by Annex B, Annex F and
        Annex M
Annex O (normative) - Instantaneous trip circuit-breakers
        (ICB)
Annex P (normative) - DC circuit-breakers for use in
        photovoltaic (PV) applications
Annex Q Vacant
Annex R (normative) - Circuit-breakers incorporating
        residual current protection with automatic
        re-closing functions
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their corresponding
         European publications
Annex ZZA (informative) - Relationship between this
          European standard and the essential requirements
          of Directive 2014/30/EU [2014 OJ L96] aimed to
          be covered and the standardisation request M/552
Annex ZZB (informative) - Relationship between this
          European standard and the safety objectives of
          Directive 2014/35/EU [2014 OJ L96] aimed to
          be covered

IEC 60947-2:2016 is available as IEC 60947-2:2016
RLV which contains the International Standard and its Redline
version, showing all changes of the technical content compared to
the previous edition.


IEC 60947-2:2016 applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. This fifth edition cancels and replaces the fourth edition published in 2006, Amendment 1:2009 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant additions with respect to the previous edition:

- tests for verification of selectivity in Annex A (see A.5.3);

- critical load current tests for d.c. circuit-breakers (see 8.3.9);

- new Annex P for circuit-breakers for use in photovoltaic applications;

- new Annex R for residual-current circuit-breakers with automatic reclosing functions.

Committee
CLC/TC 121A
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

I.S. EN 60092-507:2015 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
DIN EN 16840:2015-04 (Draft) INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, 50 HZ, AT LEAST 250 A
CEI EN 60077-3 : 2002 RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 3: ELECTROTECHNICAL COMPONENTS - RULES FOR D/C/ CIRCUIT-BREAKERS
BS EN 50156-2:2015 Electrical equipment for furnaces and ancillary equipment Requirements for design, development and type approval of safety devices and subsystems
DD ENV 50231:1997 Aeronautical ground lighting electrical installation. Constant current regulator. Equipment specifications and tests
UNE-HD 50573-5-57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
I.S. HD 50573-5-57:2014 CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL
BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
UNE-HD 60364-7-722:2016 Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
CEI EN 60092-507 : 2016 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
BS EN 60092-507:2015 Electrical installations in ships Small vessels
99/711929 DC : DRAFT JUL 1999 EN 13621 - FOOD PROCESSING MACHINERY - SALAD DRYERS - SAFETY AND HYGIENE REQUIREMENTS
DIN VDE 0660-114 : 1992 LOW-VOLTAGE SWITCH GEAR AND CONTROL GEAR; PART 6-1: MULTIPLE FUNCTION EQUIPMENT; AUTOMATIC TRANSFER SWITCHING EQUIPMENT
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
I.S. EN 60947-6-1:2005 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
BS EN 62683:2015 Low-voltage switchgear and controlgear. Product data and properties for information exchange
EN 60947-6-1:2005/A1:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013)
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
EN 60947-4-1 : 2010 AMD 1 2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
EN 60077-3:2002 Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components - Rules for d.c. circuit-breakers
EN 62683:2015 Low-voltage switchgear and controlgear - Product data and properties for information exchange
HD 384.7.711 : 200S1 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS
HD 60364-4-43:2010 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
EN 60947-6-2:2003/A1:2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-2: MULTIPLE FUNCTION EQUIPMENT - CONTROL AND PROTECTIVE SWITCHING DEVICES (OR EQUIPMENT) (CPS)
CLC/TS 62081:2002 Arc welding equipment - Installation and use
12/30268377 DC : 0 BS EN 50156-2 - ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 2: REQUIREMENTS FOR DESIGN, DEVELOPMENT AND TYPE APPROVAL OF SAFETY DEVICES AND SUBSYSTEMS
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
BS EN 61557-6:1998 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring ormonitoring of protective measures Residual current devices (RCD) in TT, TN and IT systems
S.R. HD 60364-5-537:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
10/30233953 DC : 0 BS EN 16191 - TUNNELLING MACHINERY - SAFETY REQUIREMENTS
01/712575 DC : DRAFT SEP 2001 ISO 13849-2 - SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEM - PART 2: VALIDATION
I.S. EN 50156-2:2015 ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 2: REQUIREMENTS FOR DESIGN, DEVELOPMENT AND TYPE APPROVAL OF SAFETY DEVICES AND SUBSYSTEMS
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 16840:2017 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, 50 HZ, AT LEAST 250 A
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. EN 50156-1:2015 ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 1: REQUIREMENTS FOR APPLICATION DESIGN AND INSTALLATION
S.R. HD 60364-7-712:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-712: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - PHOTOVOLTAIC (PV) SYSTEMS
I.S. HD 60364-7-721:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
I.S. EN 61557-6:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
CEI EN 50171 : 2002 CENTRAL POWER SUPPLY SYSTEMS
I.S. EN 60204-32:2008 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
EN 60947-3:2009/A2:2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015)
OVE/ONORM EN 61557-6 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
VDI 4620:2016-12 Hydroelectric installations - Technology and design
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
I.S. EN 61009-1:2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
BS EN 16840:2017 Inland navigation vessels. Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
PREN 50156-2 : DRAFT 2012 ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 2: REQUIREMENTS FOR DESIGN, DEVELOPMENT AND TYPE APPROVAL OF SAFETY DEVICES AND SUBSYSTEMS
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
EN 303 446-2 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
03/307803 DC : DRAFT MAY 2003 EN 61009-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCB'S) - PART 1: GENERAL RULES
13/30251809 DC : 0 BS EN 50171 - CENTRAL SAFETY POWER SUPPLY SYSTEMS
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
PREN 16191 : DRAFT 2010 TUNNELLING MACHINERY - SAFETY REQUIREMENTS
BS EN 60947-3 : 2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS
I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
S.R. HD 60364-7-722:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES
IEC TS 62081:1999 Arc welding equipment - Installation and use
I.S. EN 60204-1:2006 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
I.S. EN 60439-2:2000 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: PARTICULAR REQUIREMENTS FOR BUSBAR TRUNKING SYSTEMS (BUSWAYS)
UNE-HD 60364-7-712:2017 Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems
UNE-EN 60947-4-1:2011 Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
EN 61009-1:2012/A12:2016 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
UNE-HD 60364-5-53:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
UNE-EN 60204-1:2007 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
UNE-EN 60947-3:2009 Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
VDE 0558-508 : 2001 CENTRAL POWER SUPPLY SYSTEMS
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
BS EN 60947-4-1 : 2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
00/708470 DC : DRAFT APR 2000 PREN 13886 - FOOD PROCESSING MACHINERY - COOKING KETTLES EQUIPPED WITH STIRRER AND/OR MIXER - SAFETY AND HYGIENE
I.S. EN 60947-6-2:2003 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - MULTIPLE FUNCTION EQUIPMENT - CONTROL AND PROTECTIVE SWITCHING DEVICES (OR EQUIPMENT) (CPS)
PREN 50171 : DRAFT 2013 CENTRAL SAFETY POWER SUPPLY SYSTEMS
DIN VDE 0660-102 : 1992 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
S.R. HD 60364-5-53:2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
EN 60204-1 : 2006 COR 2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
I.S. EN 60898-1:2003 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002 (MOD))
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
I.S. HD 60364-7-740:2006 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
S.R. CLC/TR 50480:2011 DETERMINATION OF CROSS-SECTIONAL AREA OF CONDUCTORS AND SELECTION OF PROTECTIVE DEVICES
I.S. HD 60364-4-43:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-43: PROTECTION FOR SAFETY - PROTECTION AGAINST OVERCURRENT
I.S. EN 60077-3:2002 RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 3: ELECTROTECHNICAL COMPONENTS - RULES FOR D.C. CIRCUIT-BREAKERS
UNE-EN 61557-11:2010 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems
UNE-EN 61009-1:2013 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules
PD CLC/TR 50480:2011 Determination of cross-sectional area of conductors and selection of protective devices
DD CLC/TS 62081:2002 Arc welding equipment. Installation and use
BS EN 60898-1 : 2003 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION
EN 60092-507:2015/AC:2015 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
BS EN 50156-1:2015 Electrical equipment for furnaces and ancillary equipment Requirements for application design and installation
BS EN 61009-1 : 2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
UNE-HD 60364-4-43:2013 Low-voltage electrical installations -- Part 4-43: Protection for safety - Protection against overcurrent
12/30260546 DC : 0 BS EN 50156-1 - ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 1: REQUIREMENTS FOR APPLICATION DESIGN AND INSTALLATION
UNE-HD 60364-7-721:2011 Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans
EN 16840:2017 Inland navigation vessels - Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
HD 60364-5-537:2016/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
DIN VDE 0660-107 : 1992 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS
DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BS EN 50171:2001 Central power supply systems
BS EN 60947-6-2:2003 Low-voltage switchgear and controlgear Multiple function equipment. Control and protective switching devices (or equipment) (CPS)
UNE-EN 16840:2017 Inland navigation vessels - Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
HD 60364-7-721:2009/corrigendum:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
BS EN 60077-3:2002 Railway applications. Electric equipment for rolling stock Electrotechnical components. Rules for d.c. circuit-breakers
UNE-EN 60947-6-1:2006 Low-voltage switchgear and controlgear -- Part 6-1: Multiple function equipment - Transfer switching equipment (IEC 60947-6-1:2005)
I.S. HD 384.7.711:2003 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
HD 60364-7-722:2016 Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
I.S. EN 60947-3:2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS
S.R. HD 60364-7-740:2006 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
I.S. EN 60947-4-1:2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009 (EQV))
BS EN 60947-6-1:2005 Low-voltage switchgear and controlgear Multiple function equipment. Transfer switching equipment
HD 50573-5-57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
ENV 50231 : 1997 AVIATION GROUND LIGHTING ELECTRICAL INSTALLATION - CONSTANT CURRENT REGULATOR: EQUIPMENT SPECIFICATIONS AND TESTS
CEI EN 61557-6 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
BS EN 60204-1 : 2006 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
BS EN 60204-32:2008 Safety of machinery. Electrical equipment of machines Requirements for hoisting machines
HD 60364-5-53:2015/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
CLC/TR 50480:2011 Determination of cross-sectional area of conductors and selection of protective devices
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 50156-1:2015 Electrical equipment for furnaces and ancillary equipment - Part 1: Requirements for application design and installation
HD 60364-7-712:2016 Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems
EN 50156-2:2015 Electrical equipment for furnaces and ancillary equipment - Part 2: Requirements for design, development and type approval of safety devices and subsystems
HD 60364-7-740:2006/A11:2017 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 60204-32:2008 Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines
EN 50171 : 2001 COR 2001 CENTRAL POWER SUPPLY SYSTEMS
EN 61557-6:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
UNE-HD 60364-5-537:2017 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
IEC 62475:2010 High-current test techniques - Definitions and requirements for test currents and measuring systems
IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61131-1:2003 Programmable controllers - Part 1: General information
IEC 60934:2000+AMD1:2007+AMD2:2013 CSV Circuit-breakers for equipment (CBE)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60050-442:1998 International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC TR 60755:2008 General requirements for residual current operated protective devices
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
EN 60947-4-1 : 2010 AMD 1 2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
EN 62475 : 2010 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
EN 50557:2011 Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC TR 60664-2-1:2011 Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.